Electrochemical reduction of metronidazole at a DNA-modified glassy carbon electrode

被引:49
|
作者
Brett, AMO [1 ]
Serrano, SHP [1 ]
Gutz, I [1 ]
LaScalea, MA [1 ]
机构
[1] UNIV SAO PAULO,INST QUIM,BR-05599970 SAO PAULO,BRAZIL
来源
BIOELECTROCHEMISTRY AND BIOENERGETICS | 1997年 / 42卷 / 02期
关键词
differential pulse voltammetry; cyclic voltammetry; nitroimidazole; DNA-modified electrode; glassy carbon;
D O I
10.1016/S0302-4598(96)05122-7
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The electrochemical reduction of metronidazole was investigated using, for the first time, the newly developed DNA-modified glassy carbon electrode. The results are compared with reduction at bare glassy carbon electrodes. The potentials for reduction were less negative when using the DNA-modified glassy carbon electrode although the mechanism was the same. A potential-pH dependence of one electron per proton was observed in acid media whereas for neutral and alkaline solution no dependence was found. The DNA-modified glassy carbon electrode enables preconcentration of the sample for chosen times on the electrode surface which is convenient for analytical applications. The limit of detection using the DNA-modified glassy carbon electrode at pH 4.5 with 2 min preconcentration is 1.67 mu M, and without preconcentration it is three times higher, 3.25 mu M At a bare glassy carbon electrode, where preconcentration is not possible, the limit of detection for the same pH is 3.44 mu M. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:175 / 178
页数:4
相关论文
共 50 条
  • [1] Comparison of the voltammetric behavior of metronidazole at a DNA-modified glassy carbon electrode, a mercury thin film electrode and a glassy carbon electrode
    Brett, AMO
    Serrano, SHP
    Gutz, IGR
    LaScalea, MA
    ELECTROANALYSIS, 1997, 9 (02) : 110 - 114
  • [2] Electrochemical determination of carboplatin in serum using a DNA-modified glassy carbon electrode
    Brett, AMO
    Serrano, SHP
    Macedo, TA
    Raimundo, D
    Marques, MH
    LaScalea, MA
    ELECTROANALYSIS, 1996, 8 (11) : 992 - 995
  • [3] Electrochemical Determination of Carboplatin in Serum Using a DNA-Modified Glassy Carbon Electrode
    Brett, A. M. O.
    Serrano, S. H. P.
    Macedo, T. A.
    Raimundo, D.
    Electroanalysis, 8 (11):
  • [4] Voltammetric Determination of Anthracene Using a DNA-Modified Glassy Carbon Electrode
    Blaskova, Marta
    Hajkova, Andrea
    Vyskocil, Vlastimil
    CHEMICKE LISTY, 2015, 109 (03): : 235 - 240
  • [5] Determination of 1-naphthol with denatured DNA-modified pretreated glassy carbon electrode
    Zhao, J.
    Hu, G. -Z.
    Yang, Z. -S.
    Zhou, Y. -Y.
    ANALYTICAL LETTERS, 2007, 40 (03) : 459 - 470
  • [6] Direct Electrochemical Behavior of Cytochrome c on DNA-modified Glassy Carbon Electrode and Its Application to Cytochrome c Biosensor
    Yun-Chun Liu
    Shi-Qiang Cui
    Zhou-Sheng Yang
    Analytical Sciences, 2006, 22 : 1071 - 1074
  • [7] Electrochemical determination of paraquat using a DNA-modified carbon ionic liquid electrode
    Mai, Nannan
    Liu, Xiaoying
    Wei, Wanzhi
    Luo, Shenglian
    Liu, Wei
    MICROCHIMICA ACTA, 2011, 174 (1-2) : 89 - 95
  • [8] Electrochemical determination of paraquat using a DNA-modified carbon ionic liquid electrode
    Nannan Mai
    Xiaoying Liu
    Wanzhi Wei
    Shenglian Luo
    Wei Liu
    Microchimica Acta, 2011, 174 : 89 - 95
  • [9] Electrochemical Reduction and Voltammetric Determination of Metronidazole Benzoate at Modified Carbon Paste Electrode
    Joseph, Renjini
    Kumar, K. Girish
    ANALYTICAL LETTERS, 2009, 42 (14) : 2309 - 2321
  • [10] Electrochemical reduction of metronidazole at activated glassy carbon electrode and its determination in pharmaceutical dosage forms
    Ozkan, SA
    Ozkan, Y
    Senturk, Z
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (02) : 299 - 305