Integration of ozone, UV/H2O2 and GAC in a multi-barrier treatment for secondary effluent polishing: Reuse parameters and micropollutants removal

被引:9
|
作者
Granzoto, Mariana R. [1 ]
Seabra, Ivna [1 ]
Malvestiti, Jacqueline A. [1 ]
Cristale, Joyce [1 ]
Dantas, Renato F. [1 ]
机构
[1] Univ Estadual Campinas, Sch Technol, UNICAMP, Paschoal Marmo 1888, BR-13484332 Limeira, SP, Brazil
关键词
Ozonation; Micropollutants; Advanced oxidation processes; Multibarrier; Costs; ADVANCED OXIDATION PROCESSES; WATER TREATMENT-PLANT; WASTE-WATER; ACTIVATED CARBON; FLAME RETARDANTS; TRANSFORMATION PRODUCTS; DRINKING-WATER; PLASTICIZERS; ELIMINATION; DEGRADATION;
D O I
10.1016/j.scitotenv.2020.143498
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Current studies tend to combine different advanced treatment technologies to reduce costs and increase efficiency. The objective of thisworkwas to assess the combination of ozonation and UV/H2O2 with activated carbon adsorption for the removal of effluent quality parameters and micropollutants fromsecondary effluent samples. The experiments were carried out using the following configurations: O-3+ GAC+ O-3 (1); O-3+ GAC+ UV/H2O2 (2); UV/H2O2+ GAC+ O-3 (3); UV/H2O2+ GAC+ UV/H2O2 (4). Configurations 1, 3 and 4 were themost efficient for organic matter removal, while configuration 1 had the lowest cost on laboratory scale. An additional ultra-filtration membrane unit (UF) was tested at the end of configuration 1, which was optimized in terms of ozone doses for the removal of three organophosphate micropollutants in ultrapure water (TNBP, TCIPP and TPHP at 10 mu g L-1). The best cost-effective configuration of this treatment train was the one using 1 mg L-1 of ozone before and after GAC, which achieved around 100% of micropollutants abatement. The role of each treatment to the final micropollutant removal was also discussed, being the first ozone treatment responsible for about 15% removal of the mixture of contaminants, while GAC was responsible for an additional 80% removal. The complete treatment train reached almost 100% of contaminants removal (under detection limit of the method), as well as added security to the system. The achieved results were also compared to international reuse legislations, proving that the combination of O-3 and GACwas an interesting option to achieve enough quality for some reuse purposes. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Removal of organophosphate esters from municipal secondary effluent by ozone and UV/H2O2 treatments
    Yuan, Xiangjuan
    Lacorte, Silvia
    Cristale, Joyce
    Dantas, Renato F.
    Sans, Carme
    Esplugas, Santiago
    Qiang, Zhimin
    SEPARATION AND PURIFICATION TECHNOLOGY, 2015, 156 : 1028 - 1034
  • [2] Transformation of persistent organic micropollutants by UV and UV/H2O2 in wastewater treatment plant effluent
    Thor, Jan
    Dittmann, Daniel
    Meyer, Andreas
    Zeeshan, Muhammad
    Johne, Steffen
    Reynaert, Eva
    Ruhl, Aki Sebastian
    Water Supply, 2025, 25 (01) : 65 - 82
  • [3] Performance of UV and UV/H2O2 processes for the removal of pharmaceuticals detected in secondary effluent of a sewage treatment plant in Japan
    Kim, Ilho
    Yamashita, Naoyuki
    Tanaka, Hiroaki
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 166 (2-3) : 1134 - 1140
  • [4] Efficiency of sequential UV/H2O2 and biofilm process for the treatment of secondary effluent
    Yan, Peng-Fei
    Yuan, Shoujun
    Wang, Wei
    Hu, Zhen-Hu
    Mu, Yang
    Yu, Han-Qing
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2019, 26 (01) : 577 - 585
  • [5] Efficiency of sequential UV/H2O2 and biofilm process for the treatment of secondary effluent
    Peng-Fei Yan
    Shoujun Yuan
    Wei Wang
    Zhen-Hu Hu
    Yang Mu
    Han-Qing Yu
    Environmental Science and Pollution Research, 2019, 26 : 577 - 585
  • [6] Removal of dissolved organics in water by using UV/H2O2/GAC
    Cui Chongwei
    He Junguo
    Li Shaofeng
    Wang Xingdan
    PROGRESS IN ENVIRONMENTAL SCIENCE AND TECHNOLOGY, VOL I, 2007, : 719 - 722
  • [7] Modeling carbonate/bicarbonate and nitrate disturbance during secondary effluent disinfection by UV/H2O2 and UV/ozone
    Cavalcante, Rodrigo Pereira
    Malvestiti, Jacqueline Aparecida
    Diogo Junior, Jose Paulo
    Dantas, Renato Falcao
    WATER SCIENCE AND TECHNOLOGY, 2022, 86 (11) : 2943 - 2962
  • [8] Efficiency and energy requirements for the transformation of organic micropollutants by ozone, O3/H2O2 and UV/H2O2
    Katsoyiannis, Ioannis A.
    Canonica, Silvio
    von Gunten, Urs
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242
  • [9] Efficiency and energy requirements for the transformation of organic micropollutants by ozone, O3/H2O2 and UV/H2O2
    Katsoyiannis, Ioannis A.
    Canonica, Silvio
    von Gunten, Urs
    WATER RESEARCH, 2011, 45 (13) : 3811 - 3822
  • [10] Comparison of energy requirements for removal of organic micropollutants by ozone, O3/H2O2, UV, UV/H2O2 and boron-doped diamond (BDD) electrodes
    Matafonova, Galina
    Zimmermann, Saskia
    Dimitriou-Christidis, Petros
    Arey, Sam
    von Gunten, Urs
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245