End-To-End Test of the Gamma Knife Icon Plan Adaptation and High Definition Motion Management System Using a Motorized Anthropomorphic Head Phantom

被引:0
|
作者
Han, E. [1 ]
Luo, D. [1 ]
Kim, J. [2 ]
Tharp, K. [1 ]
Wen, Z. [1 ]
Briere, T. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Houston, TX 77030 USA
[2] Univ Pittsburgh, Med Ctr, Gibsonia, PA USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-L-SAN1-
引用
收藏
页码:E202 / E202
页数:1
相关论文
共 14 条
  • [1] Dosimetric validation of the Gamma Knife® Icon™ plan adaptation and high-definition motion management system with a motorized anthropomorphic head phantom
    Han, Eun Young
    Luo, Dershan
    Kim, Jong Oh
    Tharp, Kelly
    Wen, Zhifei
    Briere, Tina M.
    [J]. JOURNAL OF RADIOSURGERY AND SBRT, 2019, 6 (03): : 217 - 226
  • [2] An End-To-End VMAT QA Procedure Using a Customized Anthropomorphic Phantom Head
    Iwai, P.
    Hara, S.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2918 - 2918
  • [3] End-to-End test using the STEEV phantom with target definition on PET images
    Loebker, K.
    Kroesen, V. M.
    Strautmann, A.
    Wolff, R.
    Stelljes, T. S.
    Poppe, B.
    Willborn, K.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 : S101 - S101
  • [4] A New Method and Device for Calibration of High Definition Motion Management System of Gamma Knife ICON
    Feng, Y.
    Corns, R.
    Lee, S.
    Jones, K.
    Kennedy, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E690 - E690
  • [5] Feasibility of End-To-End Quality Assurance of FSRT Brain Treatments Using An In-House Developed Anthropomorphic Head Phantom
    Alexander, K. M.
    Dekker, K.
    Olding, T.
    Schreiner, L. J.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E781 - E782
  • [6] End-to-end test of an online adaptive treatment procedure in MR-guided radiotherapy using a phantom with anthropomorphic structures
    Elter, A.
    Dorsch, S.
    Mann, P.
    Runz, A.
    Johnen, W.
    Spindeldreier, C. K.
    Klueter, S.
    Karger, C. P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (22):
  • [7] End-to-end test for fractionated online adaptive MR-guided radiotherapy using a deformable anthropomorphic pelvis phantom
    Elter, A.
    Rippke, C.
    Johnen, W.
    Mann, P.
    Hellwich, E.
    Schwahofer, A.
    Dorsch, S.
    Buchele, C.
    Klueter, S.
    Karger, C. P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (24):
  • [8] Validation of the fabricated cast nylon head phantom for stereotactic radiosurgery end-to-end test using alanine dosimeter
    Intang, Aungsumalin
    Oonsiri, Puntiwa
    Kingkaew, Sakda
    Chatchumnan, Nichakan
    Oonsiri, Sornjarod
    [J]. JOURNAL OF MEDICAL PHYSICS, 2023, 48 (01) : 74 - 79
  • [9] A Quantitative Test Tool for the Gamma Knife Icon Intra-Fraction Motion Management (IFMM) System
    Napoli, J.
    Rebo, I.
    Napoli, L.
    Ndlovu, A.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E423 - E423
  • [10] Comprehensive end-to-end test for intensity-modulated radiation therapy for nasopharyngeal carcinoma using an anthropomorphic phantom and EBT3 film
    Bao, J.
    Chen, L.
    Zhu, J. H.
    Fei, Z. F.
    Hu, Z. T.
    Wang, H. Z.
    Gao, Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (01): : 31 - 39