A novel calibration strategy for the quantitative imaging of iron in biological tissues by LA-ICP-MS using matrix-matched standards and internal standardisation

被引:35
|
作者
O'Reilly, Jennifer [1 ]
Douglas, David [1 ]
Braybrook, Julian [1 ]
So, P-W. [2 ]
Vergucht, Eva [3 ]
Garrevoet, Jan [3 ]
Vekemans, Bart [3 ]
Vincze, Laszlo [3 ]
Goenaga-Infante, Heidi [1 ]
机构
[1] LGC Ltd, Teddington TW11 0LY, Middx, England
[2] Kings Coll London, Dept Neuroimaging, Inst Psychiat, London SE5 9NU, England
[3] Univ Ghent, Dept Analyt Chem, B-9000 Ghent, Belgium
关键词
PLASMA-MASS SPECTROMETRY; ABLATION; BRAIN; SECTIONS; ZN; FE; CU;
D O I
10.1039/c4ja00002a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a novel and straightforward procedure for the preparation of matrix-matched calibration standards for the quantitative imaging of iron (Fe) in biological tissues by laser ablation (LA)-ICP-MS with on-tissue internal standard addition is described. This simple approach enabled on-tissue addition of Rh as internal standard to samples (with heterogeneous Fe distribution) and calibrants (with homogeneous Fe distribution). This is achieved without altering the original Fe distribution of the sample. Calibration standards were prepared by full horizontal immersion of slides with mounted homogenised sheep brain tissue section into the corresponding solution containing 0.5, 0.75, 1, 5, 10 and 20 mg kg(-1) Fe (each also containing 250 mu g kg(-1) Rh as IS) in pure methanol for 30 minutes (6 immersions, each for 5 minutes). Subsequent air-drying (bench drying at room temperature) for approximately 5 minutes was undertaken in between consecutive immersions, to prevent long-term exposure of the tissue to lipid degradation. Tissue-matched standards were characterised in-house for Fe composition, homogeneity and stability (at storage temperatures of -80 degrees C, -20 degrees C, 4 degrees C and 25 degrees C for up to 2 months) in order to investigate their suitability as calibrants for quantitative LA-ICP-MS. The homogeneity data suggested that the materials are homogeneous in terms of Fe and Rh distribution with RSDs (n = 30) of 8.3% and 4.7%, respectively. The Fe measurement precision was improved by approximately a factor of 2 when normalising Fe-56 intensities to Rh-103 intensities; the RSD (n = 30) for Fe-56/Rh-103 was 3.6%. The produced calibration standards were found to be stable when stored at room temperature for approximately 50 days, suggesting that they can be reused for multiple batches. Using LA coupled to double-focusing sector field ICP-MS in medium resolution mode (m/Delta m = 4000), linear calibration over a range of 107 to 1519 mg kg(-1) Fe (R-2 = 0.99) was achieved with a limit of detection of 1.84 mg kg(-1) Fe. Assessment of the accuracy of the method for the quantitative imaging of Fe in tissues was undertaken by comparison of the LA-ICP-MS data with that obtained by micro-XRF; the average Fe concentrations in selected tissue regions obtained by using XRF fell within the window defined by the LA-ICP-MS values and their associated standard deviations.
引用
收藏
页码:1378 / 1384
页数:7
相关论文
共 50 条
  • [2] Preparation of matrix-matched calibration standards for accurate determination of elemental concentrations in uric acid stones by LA-ICP-MS
    Zhou, Qingling
    Chen, Xinyi
    Ao, Duoduo
    Hu, Hui
    Zhou, Jianzong
    Hu, Yongmei
    Yang, Wanqing
    Ke, Yuqiu
    Yi, Xiaoqing
    Xu, Hui
    ANALYTICAL METHODS, 2025, 17 (02) : 246 - 255
  • [3] A versatile approach for the preparation of matrix-matched standards for LA-ICP-MS analysis - Standard addition by the spraying of liquid standards
    Willner, Jakob
    Brunnbauer, Lukas
    Larisegger, Silvia
    Nelhiebel, Michael
    Marchetti-Deschmann, Martina
    Limbeck, Andreas
    TALANTA, 2023, 256
  • [4] Feasibility of Matrix-Matched Material for Determining Elements in Rice Flour by SN-ICP-MS and LA-ICP-MS
    Kukusamude, Chunyapuk
    Kongsri, Supalak
    Tamklang, Ratchadawan
    Taebunpakul, Sutthinun
    FOODS, 2024, 13 (11)
  • [5] Trace element analysis of high-Mg olivine by LA-ICP-MS - Characterization of natural olivine standards for matrix-matched calibration and application to mantle peridotites
    Bussweiler, Y.
    Giuliani, A.
    Greig, A.
    Kjarsgaard, B. A.
    Petts, D.
    Jackson, S. E.
    Barrett, N.
    Luo, Y.
    Pearson, D. G.
    CHEMICAL GEOLOGY, 2019, 524 : 136 - 157
  • [6] Imaging of essential and toxic elements in biological tissues by LA-ICP-MS
    Becker, J. Sabine
    Zoriy, Miroslav
    Wu, Bei
    Matusch, Andreas
    Becker, J. Susanne
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (09) : 1275 - 1280
  • [7] In situ U-Pb dating of cassiterite by LA-ICP-MS without a matrix-matched standard
    Chen Jing
    Hou KeJun
    Wang Qian
    Yuan ShunDa
    Chen YueLong
    ACTA PETROLOGICA SINICA, 2021, 37 (03) : 943 - 955
  • [8] Quantitative analysis of silicates using LA-ICP-MS with liquid calibration
    Halicz, L
    Günther, D
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (12) : 1539 - 1545
  • [9] Line-dropped gelatin multi-element calibration standards in LA-ICP-MS: a statistically verifying comparison with cryosectioned homogenized lung and liver as matrix-matched calibration standards and as corresponding reference materials
    Thoroee-Boveleth, Sven
    Becker, Ruth
    Bertram, Jens
    Schettgen, Thomas
    Moeller, Manfred
    Jonigk, Danny
    Kraus, Thomas
    Weiskirchen, Ralf
    ANALYTICAL SCIENCES, 2025, 41 (03) : 237 - 249
  • [10] EXPLORING INTERNAL STANDARDS AND MATRIX MATCHING FOR LANTHANIDES DETERMINATION IN TEA BY LA-ICP-MS
    Rubin, Ana Caroline Vedovato
    Neves, Vinicius Machado
    Viana, Ana Barbosa
    Riquieri, Taynara Bonfim
    Pozebon, Dirce
    Dressler, Valderi Luiz
    QUIMICA NOVA, 2025, 48 (02):