Radiation eye dose to medical staff during respiratory endoscopy under X-ray fluoroscopy

被引:29
|
作者
Haga, Yoshihiro [1 ,2 ]
Chida, Koichi [1 ,3 ]
Kimura, Yuichiro [4 ]
Yamanda, Shinsuke [4 ]
Sota, Masahiro [1 ,2 ]
Abe, Mitsuya [2 ]
Kaga, Yuji [2 ]
Meguro, Taiichiro [5 ]
Zuguchi, Masayuki [1 ]
机构
[1] Tohoku Univ, Dept Radiol Technol, Grad Sch Med, Aoba Ku, 2-1 Seiryo, Sendai, Miyagi 9808575, Japan
[2] Sendai Kousei Hosp, Dept Radiol, Aoba Ku, Hirosemachi 4-15, Sendai, Miyagi 9800873, Japan
[3] Tohoku Univ, Int Res Inst Disaster Sci, Div Disaster Med, 6-6-4 Aoba, Sendai, Miyagi 9808579, Japan
[4] Sendai Kousei Hosp, Dept Resp Med, Aoba Ku, Hirosemachi 4-15, Sendai, Miyagi 9800873, Japan
[5] Sendai Kousei Hosp, Dept Cardiovasc Med, Aoba Ku, Hirosemachi 4-15, Sendai, Miyagi 9800873, Japan
关键词
radiation safety eye lens dose; x-ray fluoroscopy; fluoroscopically guided respiratory endoscopy (bronchoscopy); dosimeter; radiation disaster medicine; 3-mm dose-equivalent [Hp(3); PROTECTION; BRONCHOSCOPY; PHYSICIANS;
D O I
10.1093/jrr/rraa034
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Although the clinical value of fluoroscopically guided respiratory endoscopy (bronchoscopy) is clear, there have been very few studies on the radiation dose received by staff during fluoroscopically guided bronchoscopy. The International Commission on Radiological Protection (ICRP) is suggesting reducing the occupational lens dose limit markedly from 150 to 20 mSv/year, averaged over defined periods of five years. The purpose of this study was to clarify the current occupational eye dose of bronchoscopy staff conducting fluoroscopically guided procedures. We measured the occupational eye doses (3-mm-dose equivalent, Hp(3)) of bronchoscopy staff (physicians and nurses) over a 6-month period. The eye doses of eight physicians and three nurses were recorded using a direct eye dosimeter, the DOSIRIS. We also estimated eye doses using personal dosimeters worn at the neck. The mean +/- SD radiation eye doses (DOSIRIS) to physicians and nurses were 7.68 +/- 5.27 and 2.41 +/- 1.94 mSv/6 months, respectively. The new lens dose limit, 20 mSv/year, may be exceeded among bronchoscopy staff, especially physicians. The eye dose of bronchoscopy staff (both physicians and nurses) was underestimated when measured using a neck dosimeter. Hence, the occupational eye dose of bronchoscopy staff should be monitored. To reduce the occupational eye dose, we recommend that staff performing fluoroscopically guided bronchoscopy wear Pb glasses. correct evaluation of the lens dose [Hp(3)] using an eye dosimeter such as the DOSIRIS is necessary for bronchoscopy staff.
引用
收藏
页码:691 / 696
页数:6
相关论文
共 50 条
  • [1] RADIATION DOSE TO STAFF IN MEDICAL X-RAY DEPARTMENTS
    ARDRAN, GM
    CROOKS, HE
    KEMP, FH
    OLIVER, R
    BRITISH JOURNAL OF RADIOLOGY, 1957, 30 (359): : 600 - 601
  • [2] Radiation Dose to the Lens of the Eye in Medical Staff Performing Fluoroscopy
    Behr-Meenen, Christiane
    von Boetticher, Heiner
    Lynnyk, Olena
    Langer, Christoph
    Kersten, Jan Felix
    Nienhaus, Albert
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2021, 118 (45): : 769 - 770
  • [3] The dose and risk factors for radiation exposure to medical staff during endobronchial ultrasonography with a guide sheath for peripheral pulmonary lesions under x-ray fluoroscopy
    Katsurada, Masahiro
    Izumo, Takehiro
    Nagai, Yuichi
    Chavez, Christine
    Kitagawa, Mayumi
    Torii, Jun
    Iwase, Takumi
    Aso, Tomohiko
    Tsuchida, Takaaki
    Sasada, Shinji
    EUROPEAN RESPIRATORY JOURNAL, 2014, 44
  • [4] The Dose and Risk Factors for Radiation Exposure to Medical Staff during Endobronchial Ultrasonography with a Guide Sheath for Peripheral Pulmonary Lesions under X-ray Fluoroscopy
    Katsurada, Masahiro
    Izumo, Takehiro
    Nagai, Yuichi
    Chavez, Christine
    Kitagawa, Mayumi
    Torii, Jun
    Iwase, Takumi
    Aso, Tomohiko
    Tsuchida, Takaaki
    Sasada, Shinji
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2014, 44 (03) : 257 - 262
  • [5] Radiation dose to staff from medical X-ray scatter in the orthopaedic theatre
    Dorman, T.
    Drever, B.
    Plumridge, S.
    Gregory, K.
    Cooper, M.
    Roderick, A.
    Arruzza, E.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (07): : 3059 - 3065
  • [6] Radiation dose to staff from medical X-ray scatter in the orthopaedic theatre
    T. Dorman
    B. Drever
    S. Plumridge
    K. Gregory
    M. Cooper
    A. Roderick
    E. Arruzza
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 3059 - 3065
  • [7] RADIATION-DOSE TO UROLOGICAL SURGEONS DURING X-RAY FLUOROSCOPY FOR PERCUTANEOUS STONE EXTRACTION
    LAW, J
    INGLIS, JA
    TOLLEY, DA
    BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (734): : 185 - 187
  • [8] THE X-RAY FOVEA, A DEVICE FOR REDUCING X-RAY DOSE IN FLUOROSCOPY
    LABBE, MS
    CHIU, MY
    RZESZOTARSKI, MS
    BANIHASHEMI, AR
    WILSON, DL
    MEDICAL PHYSICS, 1994, 21 (03) : 471 - 481
  • [9] THE X-RAY FOVEA, A DEVICE FOR REDUCING X-RAY DOSE IN FLUOROSCOPY - RESPONSE
    WILSON, D
    RZESZOTARSKI, MS
    MEDICAL PHYSICS, 1994, 21 (12) : 1887 - 1887
  • [10] THE X-RAY FOVEA, A DEVICE FOR REDUCING X-RAY DOSE IN FLUOROSCOPY - COMMENT
    WALMSLEY, JJ
    MEDICAL PHYSICS, 1994, 21 (12) : 1885 - 1885