Hepatic Lesions: Improved Image Quality and Detection with the Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction Technique-Evaluation of SPIO-enhanced T2-weighted MR Images

被引:35
|
作者
Hirokawa, Yuusuke [1 ]
Isoda, Hiroyoshi [1 ]
Maetani, Yoji S. [1 ]
Arizono, Shigeki [1 ]
Shimada, Kotaro [1 ]
Okada, Tomohisa [1 ]
Shibata, Toshiya [1 ]
Togashi, Kaori [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Diagnost Radiol, Sakyo Ku, Kyoto 6068507, Japan
关键词
PROSPECTIVE ACQUISITION CORRECTION; SUPERPARAMAGNETIC IRON-OXIDE; FOCAL LIVER-LESIONS; BREATH-HOLD; ECHO SEQUENCE; MOTION CORRECTION; UPPER ABDOMEN; PULSE SEQUENCES; HASTE SEQUENCES; PROPELLER MRI;
D O I
10.1148/radiol.2512081360
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the effectiveness of the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique for superparamagnetic iron oxide (SPIO)-enhanced T2-weighted magnetic resonance (MR) imaging with respiratory compensation with the prospective acquisition correction (PACE) technique in the detection of hepatic lesions. Materials and Methods: The institutional human research committee approved this prospective study, and all patients provided written informed consent. Eighty-one patients (mean age, 58 years) underwent hepatic 1.5-T MR imaging. Fat-saturated T2-weighted turbo spin-echo images were acquired with the PACE technique and with and without the PROPELLER method after administration of SPIO. Images were qualitatively evaluated for image artifacts, depiction of liver edge and intrahepatic vessels, overall image quality, and presence of lesions. Three radiologists independently assessed these characteristics with a five-point confidence scale. Diagnostic performance was assessed with receiver operating characteristic (ROC) curve analysis. Quantitative analysis was conducted by measuring the liver signal-tonoise ratio (SNR) and the lesion-to- liver contrast-to-noise ratio (CNR). The Wilcoxon signed rank test and two-tailed Student t test were used, and P < .05 indicated a significant difference. Results: MR imaging with the PROPELLER and PACE techniques resulted in significantly improved image quality, higher sensitivity, and greater area under the ROC curve for hepatic lesion detection than did MR imaging with the PACE technique alone (P < .001). The mean liver SNR and the lesion-to- liver CNR were higher with the PROPELLER technique than without it (P < .001). Conclusion: T2-weighted MR imaging with the PROPELLER and PACE technique and SPIO enhancement is a promising method with which to improve the detection of hepatic lesions.
引用
收藏
页码:388 / 397
页数:10
相关论文
共 16 条
  • [1] Improved Detection of Hepatic Metastases From Pancreatic Cancer Using Periodically Rotated Overlapping Parallel Lines With Enhanced Reconstruction (PROPELLER) Technique After SPIO Administration
    Hirokawa, Yuusuke
    Isoda, Hiroyoshi
    Okada, Tomohisa
    Arizono, Shigeki
    Shimada, Kotaro
    Yamamoto, Akira
    Shibata, Toshiya
    Togashi, Kaori
    INVESTIGATIVE RADIOLOGY, 2010, 45 (03) : 158 - 164
  • [2] Effectiveness of the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique for reducing motion artifacts caused by mandibular movements on fat-suppressed T2-weighted magnetic resonance (MR) images
    Shimamoto, Hiroaki
    Tsujimoto, Tomomi
    Kakimoto, Naoya
    Majima, Minami
    Iwamoto, Yuri
    Senda, Yurie
    Murakami, Shumei
    MAGNETIC RESONANCE IMAGING, 2018, 54 : 1 - 7
  • [3] Use of SPIO-enhanced T1- and T2-weighted images for the differentiation of liver lesions:: An ROC analysis
    Stroszczynski, C
    Gaffke, G
    Gretschel, S
    Rambow, A
    Jost, D
    Schlecht, I
    Schneider, U
    Schicke, B
    Hohenberger, P
    Gebauer, B
    Felix, R
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (10): : 1368 - 1375
  • [4] Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomen
    Hirokawa, Yuusuke
    Isoda, Hiroyoshi
    Maetani, Yoji S.
    Arizono, Shigeki
    Shimada, Kotaro
    Togashi, Kaori
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (04) : 957 - 962
  • [5] Gradient- and spin-echo T2-weighted imaging for SPIO-enhanced detection and characterization of focal liver lesions
    Yoshikawa, T
    Mitchell, DG
    Hirota, S
    Ohno, Y
    Oda, K
    Maeda, T
    Fujii, M
    Sugimura, K
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (05) : 712 - 719
  • [6] 3T MR Imaging of Postoperative Recurrent Middle Ear Cholesteatomas: Value of Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction Diffusion-Weighted MR Imaging
    Lehmann, P.
    Saliou, G.
    Brochart, C.
    Page, C.
    Deschepper, B.
    Vallee, J. N.
    Deramond, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (02) : 423 - 427
  • [7] MRI of the Neck at 3 Tesla Using the Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction (PROPELLER) (BLADE) Sequence Compared with T2-Weighted Fast Spin-Echo Sequence
    Ohgiya, Yoshimitsu
    Suyama, Jumpei
    Seino, Noritaka
    Takaya, Shu
    Kawahara, Masaaki
    Saiki, Makoto
    Sai, Syouei
    Hirose, Masanori
    Gokan, Takehiko
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (05) : 1061 - 1067
  • [8] Role of periodically rotated overlapping parallel lines with enhanced reconstruction diffusion-weighted imaging in correcting distortion and evaluating head and neck masses using 3 T MRI
    Chen, X.
    Xian, J.
    Wang, X.
    Wang, Y.
    Zhang, Z.
    Guo, J.
    Li, J.
    CLINICAL RADIOLOGY, 2014, 69 (04) : 403 - 409
  • [9] Decreased CSF-flow artefacts in T2 imaging of the cervical spine with periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER/BLADE)
    Ragoschke-Schumm, Andreas
    Schmidt, Peter
    Schumm, Julia
    Reimann, Georg
    Mentzel, Hans-Joachim
    Kaiser, Werner A.
    Mayer, Thomas E.
    NEURORADIOLOGY, 2011, 53 (01) : 13 - 18
  • [10] Decreased CSF-flow artefacts in T2 imaging of the cervical spine with periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER/BLADE)
    Andreas Ragoschke-Schumm
    Peter Schmidt
    Julia Schumm
    Georg Reimann
    Hans-Joachim Mentzel
    Werner A. Kaiser
    Thomas E. Mayer