7-year results of primary total hip arthroplasty with the uncemented Avenir stem

被引:7
|
作者
Erivan, Roger [1 ]
Villatte, Guillaume [1 ]
Brientini, Jean-Michel [2 ]
Kreider, David [3 ]
Descamps, Stephane [1 ]
Boisgard, Stephane [1 ]
机构
[1] Univ Clermt Auvergne, ICCF, SIGMA Clermt, CHU Clermt Ferrand,CNRS, Clermont Ferrand, France
[2] Polyclin Franche Comte, Besancon, France
[3] Zimmer Biomet, Warsaw, IN USA
关键词
Aseptic loosening; cohort follow-up; hip arthroplasty; primary hip replacement; uncemented stem; COMPACTION ENHANCES FIXATION; TITANIUM;
D O I
10.1177/1120700018810211
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims: The aim of the present study was to evaluate the 7-year functional outcome and radiographic results of primary total hip arthroplasties (THAs) performed with the uncemented Avenir stem. Patients and methods: Between January 2006 and October 2008, 100 consecutive primary hips in 92 patients were enrolled at 2 centres. The mean age at operation was 58.5 years (27-87 years). Mini-incision (50%) and standard approaches (50%) were used to implant 22 standard and 78 lateralised stems. Results: The 7-year Kaplan-Meier survival rate was 98.9% (95% CI, 92.9-99.8) with stem revision for any reason as endpoint. No stem related complications occurred. 1 stem revision was due to deep infection at 51 months post-op. We had 4 acetabular revisions. The mean Harris Hip Score (HHS) at 7 years follow-up was 93.1 points (60-100). Radiographic analysis showed 2 patients had non-progressive radiolucent lines and no patient had any signs of stem subsidence or loosening. Conclusion: The 7-year implant survival and the functional outcomes for THA performed with the study device are excellent and were in line with those documented for comparable contemporary uncemented fully HA-coated stems. Longer term follow-up of this consecutive series needs to be performed.
引用
收藏
页码:418 / 423
页数:6
相关论文
共 50 条
  • [1] Revision total hip arthroplasty with an uncemented primary stem in 79 patients
    Fritz Thorey
    Matthias Lerch
    Heike Kiel
    Gabriela von Lewinski
    Christina Stukenborg-Colsman
    Henning Windhagen
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 673 - 678
  • [2] Revision total hip arthroplasty with an uncemented primary stem in 79 patients
    Thorey, Fritz
    Lerch, Matthias
    Kiel, Heike
    von Lewinski, Gabriela
    Stukenborg-Colsman, Christina
    Windhagen, Henning
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (07) : 673 - 678
  • [3] Primary Total Hip Arthroplasty With an Uncemented Femoral Component Five- to Nine-Year Results
    Casper, David S.
    Kim, Gregory K.
    Restrepo, Camilo
    Parvizi, Javad
    Rothman, Richard H.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (06): : 838 - 841
  • [4] Primary total hip arthroplasty with an uncemented femoral component: Two- to seven-year results
    Lettich, Thomas
    Tierney, Mary G.
    Parvizi, Javad
    Sharkey, Peter F.
    Rothman, Richard H.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (07): : 43 - 46
  • [5] The uncemented primary bicontact stem in revision total hip arthroplasty in young patients
    Thorey, F.
    Lerch, M.
    Kiel, H.
    von Lewinski, G.
    Stukenborg-Colsman, C.
    Windhagen, H.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2007, 145 : S40 - S43
  • [6] Minimum 15-Year Results of a Dual-Offset Uncemented Femoral Stem in Total Hip Arthroplasty
    Panichkul, Phonthakorn
    McCalden, Richard W.
    MacDonald, Steven J.
    Somerville, Lyndsay E.
    Naudie, Douglas N.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (12): : 2992 - 2998
  • [7] The mid-term results of a dual offset uncemented stem for total hip arthroplasty
    Danesh-Clough, Tony
    Bourne, Robert B.
    Rorabeck, Cecil H.
    McCalden, Richard
    JOURNAL OF ARTHROPLASTY, 2007, 22 (02): : 195 - 203
  • [8] Peroperative fractures in uncemented total hip arthroplasty: results with a single design of stem implant
    Ricardo Fernandez-Fernandez
    Elena García-Elias
    Enrique Gil-Garay
    International Orthopaedics, 2008, 32 (3) : 315 - 315
  • [9] Fifteen-year Results of Precoated Femoral Stem in Primary Hybrid Total Hip Arthroplasty
    Suh, Dong Hun
    Yun, Ho Hyun
    Chun, Sung Kwang
    Shon, Won Yong
    CLINICS IN ORTHOPEDIC SURGERY, 2013, 5 (02) : 110 - 117
  • [10] Eleven-Year Results of the Anatomic Coated CFP Stem in Primary Total Hip Arthroplasty
    Kendoff, Daniel O.
    Citak, Mustafa
    Egidy, Claus C.
    O'Loughlin, Padhraig F.
    Gehrke, Thorsten
    JOURNAL OF ARTHROPLASTY, 2013, 28 (06): : 1047 - 1051