Photoacoustic CO2 Detection at 2.7 μm

被引:1
|
作者
Wolff, Marcus [1 ,2 ]
Groninga, Hinrich G. [1 ]
Harde, Hermann [3 ]
机构
[1] PAS Tech GmbH, Bahnhofstr 3, D-19246 Zarrentin, Germany
[2] Hamburg Univ Appl Sci, D-20099 Hamburg, Germany
[3] Helmut Schmidt Univ, D-22043 Hamburg, Germany
来源
OPTICAL SENSING II | 2006年 / 6189卷
关键词
photoacoustic spectroscopy; distributed feedback; diode laser; carbon dioxide; isotopes; absorption; spectrum;
D O I
10.1117/12.661736
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present a new detection scheme for carbon dioxide (CO2) based on a custom-made room temperature distributed feedback (DFB) diode laser at 2.7 mu m, currently representing the laser with the highest emission wavelength of its kind. The detector's especially compact and simple set-up is based on photoacoustic spectroscopy (PAS). This method makes use of the transformation of absorbed modulated radiation into a sound wave. The sensor enables a very high detection sensitivity for CO2 in the ppb range. Furthermore, the carefully selected spectral region as well as the narrow bandwidth and wide tunability of the single-mode laser ensure an excellent selectivity. Even measurements of different CO2 isotopes can be easily performed. This could enable future applications of this spectroscopic sensor in medical diagnostics (e.g. C-13-breath tests).
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Photoacoustic CO2 sensor based on a DFB diode laser at 2.7 μm
    M. Wolff
    M. Germer
    H. G. Groninga
    H. Harde
    The European Physical Journal Special Topics, 2008, 153 : 409 - 413
  • [2] Photoacoustic CO2 sensor based on a DFB diode laser at 2.7 μm
    Wolff, M.
    Germer, M.
    Groninga, H. G.
    Harde, H.
    EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2008, 153 (1): : 409 - 413
  • [3] Photoacoustic detection of CO2 based on LABVIEW at 10.303 μm
    Zhao, Junjuan
    Zhao, Zhan
    Du, Lidong
    Geng, Daoqu
    Wu, Shaohua
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (04):
  • [4] Influence of molecular relaxation dynamics on quartz-enhanced photoacoustic detection of CO2 at λ=2 μm
    Wysocki, G.
    Kosterev, A. A.
    Tittel, F. K.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 85 (2-3): : 301 - 306
  • [5] Influence of molecular relaxation dynamics on quartz-enhanced photoacoustic detection of CO2 at λ =2 μm
    G. Wysocki
    A.A. Kosterev
    F.K. Tittel
    Applied Physics B, 2006, 85 : 301 - 306
  • [6] Miniaturized nonresonant photoacoustic gas analyzer for CO2 detection
    Zhang, Guangyin
    Guo, Min
    Zhao, Xinyu
    Cui, Dongyu
    Xu, Lin
    Wang, Nan
    Ni, Rui
    Qi, Hongchao
    Zhao, Jikuan
    Chen, Ke
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2023, 65 (06) : 1829 - 1837
  • [7] Towards traceability in CO2 line strength measurements by TDLAS at 2.7 μm
    Pogany, Andrea
    Ott, Oliver
    Werhahn, Olav
    Ebert, Volker
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2013, 130 : 147 - 157
  • [8] ABSOLUTE INTENSITIES OF CO2 BANDS IN THE 2.7-MU-M REGION
    DEELEY, CM
    JOHNS, JWC
    JOURNAL OF MOLECULAR SPECTROSCOPY, 1988, 129 (01) : 151 - 159
  • [9] THE 2.7-MU-BANDS OF CO2
    FRANCE, WL
    DICKEY, FP
    PHYSICAL REVIEW, 1954, 94 (05): : 1423 - 1423
  • [10] Photoacoustic Detection of CO2 Based on Mid-Infrared LED
    Li Zhengang
    Si Ganshang
    Ning Zhiqiang
    Liu Jiaxiang
    Fang Yonghua
    Cheng Zhen
    Si Beibei
    Yang Changping
    ACTA OPTICA SINICA, 2022, 42 (13)