Impact of different setup approaches in image-guided radiotherapy as primary treatment for prostate cancer

被引:0
|
作者
Schiller, Kilian [1 ]
Petrucci, Alessia [2 ]
Geinitz, Hans [3 ]
Schuster, Tibor [4 ]
Specht, Hanno [1 ]
Kampfer, Severin [1 ]
Duma, Marciana Nona [1 ]
机构
[1] Tech Univ Munich, Dept Radiat Oncol, Klinikum Rechts Isar, D-81675 Munich, Germany
[2] Univ Florence, Dept Radiat Oncol, Florence, Italy
[3] Krankenhaus Barmherzigen Schwestern Linz, Dept Radiat Oncol, Linz, Austria
[4] Tech Univ Munich, Klinikum Rechts Isar, Inst Med Stat & Epidemiol, D-80290 Munich, Germany
关键词
Prostate cancer; IGRT; Helical tomotherapy; Patient positioning; Radiotherapy setup errors; INTRAFRACTION MOTION; ENDORECTAL BALLOON; HELICAL TOMOTHERAPY; MARGINS; INTERFRACTION;
D O I
10.1007/s00066-014-0629-x
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim. The goal of this study was to assess the impact of different setup approaches in image-guided radiotherapy (IMRT) of the prostatic gland. Methods. In all, 28 patients with prostate cancer were enrolled in this study. After the placement of an endorectal balloon, the planning target volume (PTV) was treated to a dose of 70 Gy in 35 fractions. A simultaneously integrated boost (SIB) of 76 Gy (2.17 Gy per fraction and per day) was delivered to a smaller target volume. All patients underwent daily prostate-aligned IGRT by megavoltage CT (MVCT). Retrospectively, three different setup approaches were evaluated by comparison to the prostate alignment: setup by skin alignment, endorectal balloon alignment, and automatic registration by bones. Results. A total of 2,940 setup deviations were analyzed in 980 fractions. Compared to prostate alignment, skin mark alignment was associated with substantial displacements, which were >= 8 mm in 13 %, 5 %, and 44 % of all fractions in the lateral, longitudinal, and vertical directions, respectively. Endorectal balloon alignment yielded displacements >= 8 mm in 3 %, 19 %, and 1 % of all setups; and >= 3 mm in 27 %, 58 %, and 18 % of all fractions, respectively. For bone matching, the values were 1 %, 1 %, and 2 % and 3 %, 11 %, and 34 %, respectively. Conclusion. For prostate radiotherapy, setup by skin marks alone is inappropriate for patient positioning due to the fact that, during almost half of the fractions, parts of the prostate would not be targeted successfully with an 8-mm safety margin. Bone matching performs better but not sufficiently for safety margins <= 3 mm. Endorectal balloon matching can be combined with bone alignment to increase accuracy in the vertical direction when prostate-based setup is not available. Daily prostate alignment remains the gold standard for high-precision radiotherapy with small safety margins.
引用
收藏
页码:722 / 726
页数:5
相关论文
共 50 条
  • [1] The impact of different setup approches in image-guided radiotherapy as primary treatment for prostate cancer: a study of 980 fractions
    Schiller, K.
    Petrucci, A.
    Geinitz, H.
    Schuster, T.
    Specht, H.
    Kampfer, S.
    Duma, M. N.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 : 138 - 138
  • [2] SETUP ACCURACY WITH THE USE OF CBCT IMAGE-GUIDED RADIOTHERAPY IN THE TREATMENT OF PROSTATE CANCER
    Dionisi, Francesco
    Bortolato, Barbara
    Bracco, Francesco
    Palazzi, Mauro
    ANTICANCER RESEARCH, 2011, 31 (05) : 1874 - 1875
  • [3] Image-guided radiotherapy for prostate cancer
    Lohr, F.
    Boda-Heggemann, J.
    Wenz, F.
    Wiegel, T.
    AKTUELLE UROLOGIE, 2007, 38 (05) : 386 - 391
  • [4] Image-guided radiotherapy for prostate cancer
    Dang, Audrey
    Kupelian, Patrick A.
    Cao, Minsong
    Agazaryan, Nzhde
    Kishan, Amar U.
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2018, 7 (03) : 308 - 320
  • [5] Image-guided radiotherapy contribution and patient setup for anorectal cancer treatment
    Masson, I.
    Delpon, G.
    Vendrely, V.
    CANCER RADIOTHERAPIE, 2018, 22 (6-7): : 622 - 630
  • [6] Comparison of different image-guided setups for radiotherapy of prostate cancer
    Feng, Y.
    Yi, B.
    Patel, S.
    Kwok, Y.
    Yu, C.
    MEDICAL PHYSICS, 2006, 33 (06) : 2028 - 2028
  • [7] Image-guided radiotherapy for hypofractionated treatment of prostate
    Garibaldi, C.
    Zerini, D.
    Cambria, R.
    Tagaste, B.
    Fossa, B. Jereczek
    Cattani, F.
    Ferrariz, AM.
    Serafini, F.
    Orecchia, R.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S171 - S171
  • [8] The impact of image guided radiotherapy in the primary treatment of prostate cancer with a simultaneous integrated boost
    Duma, M. N.
    Petrucci, A.
    Molls, M.
    Geinitz, H.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (09) : 598 - 598
  • [9] Comparison of Image-guided Radiotherapy Technologies for Prostate Cancer
    Das, Satya
    Liu, Tian
    Jani, Ashesh B.
    Rossi, Peter
    Shelton, Joseph
    Shi, Zheng
    Khan, Mohammad K.
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2014, 37 (06): : 616 - 623
  • [10] Image-guided radiotherapy in prostate cancer: Concepts and implications
    Crehange, G.
    Martin, E.
    Supiot, S.
    Chapet, O.
    Mazoyer, F.
    Naudy, S.
    Maingon, P.
    CANCER RADIOTHERAPIE, 2012, 16 (5-6): : 430 - 438