Investigations on indoor environmental conditions and natural ventilation in school buildings.

被引:6
|
作者
Hellwig, Runa Tabea
Antretter, Florian
Holm, Andreas
Sedlbauer, Klaus
机构
关键词
WINDOWS;
D O I
10.1002/bapi.200910013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Investigations on indoor environmental conditions and natural ventilation in school buildings. There are more than 40,000 school buildings in Germany. Most of them are awaiting retrofitting. Retrofitting is not only intended to improve the energetic standards, but first of all to improve indoor environmental conditions for pupils and teachers. As most of German schools are not equipped with mechanical ventilation systems, natural ventilation controlled by the occupants opening the windows is the main way to maintain healthy and comfortable conditions in the classrooms. For that purpose the influence of window opening behaviour of the occupants on the indoor environment was measured in two German schools. Temperature and carbon dioxide concentration of the indoor air as well as the outdoor climate conditions were measured. In one school the frequency of window opening was recorded. Besides high CO2-concentrations especially during winter some of the investigated classrooms are additionally to cold in winter or to hot in summer Some classrooms do not have a shading device or the shading device is insufficient or it constricts the ventilation of the room. Windows are used as controls in some degree during lessons and during the breaks. But windows get closed after lessons and stay closed until next morning. There is no night or early morning ventilation in summer A significant weak to moderate positive correlation between total open window ratio and indoor temperature has been found. Correlation between total open window ratio and outdoor temperature is not significant in most cases or show a weak correlation coefficient.
引用
收藏
页码:89 / 98
页数:10
相关论文
共 50 条
  • [1] The ventilation of school buildings.
    Clay, F
    LANCET, 1903, 1 : 760 - 760
  • [2] Indoor conditions in silesian buildings with natural ventilation
    Nantka, Marian B.
    INDOOR AND BUILT ENVIRONMENT, 2006, 15 (06) : 571 - 582
  • [3] Pressure ventilation in buildings.
    Brabbee, K
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1908, 52 : 331 - 337
  • [4] Effect of ventilation on indoor environmental quality in buildings
    Kapalo, Peter
    Sedlakova, Anna
    Kosicanova, Danica
    Voznyak, Orest
    Lojkovics, Jan
    Siroczki, Pavol
    9TH INTERNATIONAL CONFERENCE ENVIRONMENTAL ENGINEERING (9TH ICEE) - SELECTED PAPERS, 2014,
  • [5] Applied Ventilation in Residential Buildings.
    Bless, H.
    Ki Klima Kaelte Heizung, 1985, 13 (05): : 205 - 210
  • [6] Cost-effectiveness Analysis of Improved Indoor Temperature and Ventilation Conditions in School Buildings
    Ito, Kazuhide
    Murakami, Shuzo
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2010, 9 (02) : 523 - 529
  • [7] PREDICTING NATURAL VENTILATION FORCES UPON LOW-RISE BUILDINGS.
    Lee, B.E.
    Hussain, M.
    Soliman, B.
    ASHRAE Journal, 1980, 22 (02) : 35 - 39
  • [8] INDOOR CLIMATE AND ENERGY CONSUMPTION IN BUILDINGS WITH NATURAL VENTILATION
    Nantka, Marian B.
    ARCHITECTURE CIVIL ENGINEERING ENVIRONMENT, 2008, 1 (03) : 107 - 118
  • [9] Ventilation and Air Heating of Residential Buildings.
    Bierling, H.-J.
    Eta. Elektrowarme im technischen Ausbau, 1985, 43 (01):
  • [10] Predicting natural ventilation flows in whole buildings. Part 2: The Esherick House
    Preston Stoakes
    Ulrike Passe
    Francine Battaglia
    Building Simulation, 2011, 4 : 365 - 377