Prostate delineation using CT and MRI for radiotherapy patients with bilateral hip prostheses

被引:25
|
作者
Rosewall, Tara [1 ]
Kong, Vickie
Vesprini, Danny
Catton, Charles
Chung, Peter
Menard, Cynthia
Bayley, Andrew
机构
[1] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
关键词
Prostate cancer; Radiotherapy; Hip replacement; Target definition; Image registration; METAL ARTIFACT REDUCTION; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; FIDUCIAL MARKERS; INTEROBSERVER VARIABILITY; PELVIC RADIOTHERAPY; DOSE DISTRIBUTION; CANCER; DEFINITION; LOCALIZATION;
D O I
10.1016/j.radonc.2008.11.015
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Prostate cancer patients with bilateral hip prostheses (b-HP) are rare, but pose unique challenges for high-dose radiotherapy. The purpose of this study was to determine the effect of b-HP on prostate delineation using CT and MR. Methods and materials: The planning CT and MR of 7 patients with b-HP were co-registered. Four observers delineated the prostate on both data sets, blinded to the volumes delineated by their peers and those on the alternate image set. Inter-modality differences and inter-observer variability were quantified by Calculating 3D volume overlaps. The effect of prostheses physical extent on these variables was evaluated. MR geometric distortion was explored using the differences in vector distances between three intra-prostatic markers (IPMs) on CT and MR. Results: Prostate volumes on CT were consistently larger than MR volumes in all patients when averaged over the 4 observers (+10% to +46%, p < 0.001). The mean inter-modality Volume overlap was 1.59, which varied significantly between patients (1.35 to 1.82, p = 0.04). There was a trend toward smaller inter-observer variability in the MR volumes (1.95 vs. 1.71, p = 0.08). No differences could be identified between the IPM vectors on CT and MR. Conclusions: Although limited by a small sample size, this study found that MR prostate volumes were significantly smaller than those from CT for b-HP patients. The largest differences between CT and MR prostate volumes and the greatest inter-observer variability on CT tended to be seen in patients with the largest prostheses. b-HP do not appear to cause measurable MR geometric distortions in the sequences used. Crown Copyright (C) 2008 Published by Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 90 (2009) 325-330
引用
收藏
页码:325 / 330
页数:6
相关论文
共 50 条
  • [1] Radiotherapy toxicity in prostate cancer patients with bilateral hip prostheses
    Fischer, A.
    Hoskin, P.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1090 - S1091
  • [2] Prostate Contouring in Patients with Bilateral Hip Prostheses: Impact of Using Artifact-Reduced CT Images and MRI
    Elzibak, A.
    Loblaw, A.
    Morton, G.
    Vesprini, D.
    Liu, S.
    Chung, H.
    Davidson, M.
    MEDICAL PHYSICS, 2016, 43 (06) : 3444 - 3445
  • [3] Transperineal ultrasound for aiding target volume delineation and monitoring during prostate cancer radiotherapy in men with bilateral hip prostheses
    Hilman, Serena Jayne
    Bird, Thomas
    Gieryluk, Piotr
    Richardson, Amy
    Jacobs, Petra
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 147 - 151
  • [4] CT/MRI IMAGE REGISTRATION IN PROSTATE RADIOTHERAPY PLANNING OF PATIENTS WITH UNI- AND BI-LATERAL HIP PROSTHESES
    Brunt, J.
    Haridass, A.
    Malik, Z.
    Vee, C. Eswar
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S184 - S184
  • [5] OPTIMAL TECHNIQUE FOR DOSE-ESCALATED RADIOTHERAPY TO THE PROSTATE GLAND IN PATIENTS WITH BILATERAL HIP PROSTHESES
    Kong, V.
    Rosewall, T.
    Catton, C.
    Chung, P.
    Menard, C.
    Warde, P.
    Vesprini, D.
    Bayley, A.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S449 - S449
  • [6] FEASIBILITY OF DOSE ESCALATED EXTERNAL BEAM RADIOTHERAPY IN PROSTATE CANCER PATIENTS WITH UNILATERAL AND BILATERAL HIP PROSTHESES
    Haridass, A.
    Brunt, J.
    Malik, Z.
    Vee, C. Eswar
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S212 - S213
  • [7] Evaluation of VMAT Planning Strategies for Prostate Patients with Bilateral Hip Prostheses
    To, D.
    Xhaferllari, I.
    Liu, M.
    Liang, J.
    Knill, C.
    Yan, D.
    Nandalur, S.
    Gustafson, G.
    Lack, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E430 - E430
  • [8] MRI only in a patient with prostate cancer with bilateral metal hip prostheses: case study
    Felisi, Marco
    Monti, Angelo Filippo
    Lizio, Domenico
    Nici, Stefania
    Pellegrini, Roberto Giuseppe
    Riga, Stefano
    Bortolato, Barbara
    Brambilla, Maria Grazia
    Carbonini, Claudia
    Abujami, Mohammed
    Carsana, Chiara
    Sibio, Daniela
    Potente, Carmelina
    Vanzulli, Angelo
    Palazzi, Mauro Filippo
    Torresin, Alberto
    TUMORI JOURNAL, 2021, 107 (06): : NP41 - NP44
  • [9] Automatic registration of the prostate on MRI scans to CT scans for radiotherapy target delineation
    Betgen, A.
    Pos, F.
    Schneider, C.
    van Herk, M.
    Remeijer, P.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S119 - S119
  • [10] Radiotherapy-induced toxicity in prostate cancer patients with hip prostheses
    Andrea M. Fischer
    Peter J. Hoskin
    Radiation Oncology, 17