The efficacy of the Cook-Swartz implantable Doppler in the detection of free-flap compromise: a systematic review protocol

被引:9
|
作者
Agha, Riaz A. [1 ]
Gundogan, Buket [2 ]
Fowler, Alexander J. [3 ]
Bragg, Thomas W. H. [1 ]
Orgill, Dennis P. [4 ]
机构
[1] Stoke Mandeville Hosp, Dept Plast Surg, Aylesbury HP21 8AL, Bucks, England
[2] UCL, Sch Med, London W1N 8AA, England
[3] QMUL, Barts & London Sch Med & Dent, London, England
[4] Brigham & Womens Hosp, Div Plast Surg, Boston, MA 02115 USA
来源
BMJ OPEN | 2014年 / 4卷 / 03期
关键词
Surgery; RECONSTRUCTIVE SURGERY; BREAST RECONSTRUCTION; MEDICINAL LEECHES; SALVAGE; PROBE; EXPERIENCE; HEAD;
D O I
10.1136/bmjopen-2013-004253
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction The Cook-Swartz implantable Doppler monitors venous or arterial blood flow from free flaps and can detect free-flap compromise. Previous studies have shown that the use of this Doppler can improve detection and salvage rates as it provides an earlier warning than the current method of clinical assessment. Such studies assert that the implantable Doppler is of great value in monitoring free flaps in current microsurgical units. This systematic review aims to compare the efficacy of the Cook-Swartz implantable Doppler in monitoring free-flap compromise against conventional clinical free-flap monitoring techniques. Methods and analysis Various electronic databases will be systematically searched for studies that compare the use of Cook-Swartz implantable Doppler with clinical assessment. The selected studies will then have their titles and abstracts screened by two authors. Articles selected after title and abstract screen will have full text downloaded and the complete article will be assessed for suitability. Once the articles have been selected for inclusion, data extraction will take place. For data analysis, the outcomes of the studies will be tabulated, with descriptive statistics performed as appropriate and the detection rate of the Doppler and clinical assessment will be compared and synthesised where possible. Ethics and dissemination The authors hope to disseminate the findings as widely as possible. This systematic review will be published in a peer-reviewed journal and include a number of recommendations as its conclusion based on the evidence contained within. Given the wide range of specialties now utilising flaps, it will be presented at a wide range of national and international conferences. Protocol Registration in PROSPERO CRD42013005818 The literature search and data extraction went on until 28 January 2014. These steps were revised in line with peer review comments.
引用
下载
收藏
页数:5
相关论文
共 50 条
  • [1] The efficacy of the Cook-Swartz implantable Doppler in the detection of free flap compromise: a systematic review and meta-analysis
    Agha, R. A.
    Gundogan, B.
    Fowler, A. J.
    Bragg, T. W. H.
    Orgill, D. P.
    BRITISH JOURNAL OF SURGERY, 2015, 102 : 55 - 55
  • [2] The Efficacy of the Cook-Swartz Implantable Doppler in the Detection of Free Flap Compromise: A Systematic Review and Meta-Analysis
    Agha, R. A.
    Gundogan, B.
    Fowler, A. J.
    Bragg, T. W. H.
    Orgill, D. P.
    BRITISH JOURNAL OF SURGERY, 2015, 102 : 173 - 173
  • [3] The implantable Cook-Swartz Doppler probe for postoperative monitoring in head and neck free flap reconstruction
    Guillemaud, Jennifer P.
    Seikaly, Hadi
    Cote, David
    Allen, Heather
    Harris, Jeffrey R.
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2008, 134 (07) : 729 - 734
  • [4] A study of 8 years with Cook-Swartz Doppler in Free-Flap operations, Macro, Micro and Re-exploration results
    Schmulder, A.
    BRITISH JOURNAL OF SURGERY, 2010, 97 : S82 - S83
  • [5] A comparison of the Cook-Swartz Doppler with conventional clinical methods for free flap monitoring: A systematic review and a meta-analysis
    Han, Zhao-Feng
    Guo, Li-Li
    Liu, Lin-Bo
    Li, Qian
    Zhou, Jian
    Wei, Ai-Zhou
    Guo, Peng-Fei
    INTERNATIONAL JOURNAL OF SURGERY, 2016, 32 : 109 - 115
  • [6] The Implantable Cook-Swartz Doppler Flow Probe in Kidney Transplantation
    Crane, Jeremy S.
    Aboutaleb, Esam
    Syed, Asim
    Rajagopal, Payyamozhi
    Canelo, Ruben
    Hakim, Nadey S.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2010, 10 : 249 - 249
  • [7] Use of the Cook-Swartz Doppler Probe in Post-Operative Free Flap Monitoring
    Luck, J.
    BRITISH JOURNAL OF SURGERY, 2015, 102 : 194 - 194
  • [8] EIGHT-YEAR EXPERIENCE OF THE COOK-SWARTZ DOPPLER IN FREE-FLAP OPERATIONS: MICROSURGICAL AND REEXPLORATION RESULTS WITH REGARD TO A WIDE SPECTRUM OF SURGERIES
    Schmulder, Ariel
    Gur, Eyal
    Zaretski, Arik
    MICROSURGERY, 2011, 31 (01) : 1 - 6
  • [9] POSTOPERATIVE MONITORING OF LOWER LIMB FREE FLAPS WITH THE COOK-SWARTZ IMPLANTABLE DOPPLER PROBE: A CLINICAL TRIAL
    Rozen, Warren M.
    Enajat, Morteza
    Whitaker, Iain S.
    Lindkvist, Ulrica
    Audolfsson, Thorir
    Acosta, Rafael
    MICROSURGERY, 2010, 30 (05) : 354 - 360
  • [10] Implantable Cook-Swartz Doppler probe versus Synovis Flow Coupler for the post-operative monitoring of free flap breast reconstruction
    Um, Grace T.
    Chang, Jeff
    Louie, Otway
    Colohan, Shannon M.
    Said, Hakim K.
    Neligan, Peter C.
    Mathes, David W.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2014, 67 (07): : 960 - 966