Dual mode transducer for ultrasound monitored thermal therapy

被引:0
|
作者
Guillaume, Bouchoux [1 ,2 ]
Remi, Berriet [1 ]
Cyril, Lafon [2 ]
Gerard, Fleury [1 ]
Dominique, Cathignol [2 ]
Jean-Yves, Chapelon [2 ]
机构
[1] Imasonic, 15 Rue A Savary, F-25000 Besancon, France
[2] Inserm, U 556, F-69424 Lyon, France
来源
THERAPEUTIC ULTRASOUND | 2006年 / 829卷
关键词
ultrasound; interstitial; therapy; monitoring; transducer;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A flat single element transducer able to perform and to monitor interstitial therapy is studied. This transducer must generate the acoustic intensity necessary to induce thermal lesions. It must also meet real-time monitoring requirements. A 3x8 mm(2) 7.5 MHz composite transducer was built Acoustic intensities up to 30 W/cm(2) emitted during more than 20 s with efficiency around 80% were measured. The length of the impulse response at -30 dB was 3 periods (0.3 mm). Insertion losses were found to be around 6 dB. A system interrupting high intensity emission periodically in order to acquire RF echo lines was set up. In-vitro tests on porcine liver were done. M-mode images showing the evolution of the lesion depth during the high intensity emission were obtained. The lesion depth estimated on M-mode images was well correlated with the depth measured on the liver samples after the experiments. In this study, we demonstrated that thermal lesions can be both generated and monitored by a specially-designed flat ultrasound transducer.
引用
收藏
页码:390 / +
页数:2
相关论文
共 50 条
  • [1] Dual-mode ultrasound transducer for image-guided interstitial thermal therapy
    Bouchoux, Guillaume
    Lafon, Cyril
    Berriet, Remi
    Chapelon, Jean Yves
    Fleury, Gerard
    Cathignol, Dominique
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (04): : 607 - 616
  • [2] Dual-mode transducers for ultrasound imaging and thermal therapy
    Owen, N. R.
    Chapelon, J. Y.
    Bouchoux, G.
    Berriet, R.
    Fleury, G.
    Lafon, C.
    ULTRASONICS, 2010, 50 (02) : 216 - 220
  • [3] Thermal Control of a Dual Mode Parametric Sapphire Transducer
    Belfi, Jacopol
    Beverini, Nicolo
    De Michele, Andrea
    Gabbriellini, Gianluca
    Mango, Francesco
    Passaquieti, Roberto
    2009 JOINT MEETING OF THE EUROPEAN FREQUENCY AND TIME FORUM AND THE IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, VOLS 1 AND 2, 2009, : 260 - 262
  • [4] Thermal Control of a Dual Mode Parametric Sapphire Transducer
    Belfi, Jacopo
    Beverini, Nicolo
    De Michele, Andrea
    Gabbriellini, Gianluca
    Mango, Francesco
    Passaquieti, Roberto
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (01) : 121 - 125
  • [5] Dual mode ultrasound therapy/imaging
    Slayton, M
    Barthe, P
    Jaeger, P
    Makin, I
    Gallagher, L
    Mast, TD
    Faidi, W
    Runk, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1818 - 1818
  • [6] Dual-Use Transducer for Ultrasound Imaging and Pulsed Focused Ultrasound Therapy
    Karzova, Maria M.
    Yuldashev, Petr, V
    Khokhlova, Vera A.
    Nartov, Fedor A.
    Morrison, Kyle P.
    Khokhlova, Tatiana D.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (09) : 2930 - 2941
  • [7] Interstitial Thermal Ablation With a Fast Rotating Dual-Mode Transducer
    Bouchoux, Guillaume
    Owen, Neil R.
    Chavrier, Francoise
    Berriet, Remi
    Fleury, Gerard
    Chapelon, Jean-Yves
    Lafon, Cyril
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (05) : 1086 - 1095
  • [8] Dual frequency mode transducer
    Lan, J
    Boucher, SG
    OCEANS '96 MTS/IEEE, CONFERENCE PROCEEDINGS, VOLS 1-3 / SUPPLEMENTARY PROCEEDINGS: COASTAL OCEAN - PROSPECTS FOR THE 21ST CENTURY, 1996, : 763 - 766
  • [9] Dual-mode 5-element transducer for image-guided interstitial ultrasound therapy: In vitro evaluation
    Owen, N. R.
    Bouchoux, G.
    Murillo-Rincon, A.
    Merouche, S.
    Birer, A.
    Chapelon, J. Y.
    Berriet, R.
    Fleury, G.
    Lafon, C.
    8TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2009, 1113 : 347 - +
  • [10] Validation of an intracardiac ultrasonic therapy-imaging dual mode transducer
    Kwiecinski, W.
    Provost, J.
    Dubois, R.
    Sacher, F.
    Haissaguerre, M.
    Legros, M.
    Nguyen-Dinh, A.
    Dufait, R.
    Tanter, M.
    Pernot, M.
    IRBM, 2015, 36 (06) : 351 - 354