Background: The latest methacholine challenge testing (MCT) guidelines published by the European Respiratory Society recommend the characterization of nebulizers before their use in clinics and research. Such investigations are necessary for accurately determining the provocative dose of methacholine causing a 20% fall in FEV1 (PD20) delivered by a given device. The standard English Wright (Wright) jet nebulizer recommended in the 1999 guidelines by the American Thoracic Society has become difficult to obtain and possesses some characteristics that complicate the calculation of dose delivery from this device (e.g. evaporation). Our objective was to determine if the Aerogen (R) Solo (Solo) vibrating mesh nebulizer provides similar methacholine challenge test results compared to the currently used Wright jet nebulizer. Methods: Sixty mild-to-moderate asthmatics were studied across three research sites in a randomized crossover study. Bothmethacholine challenges were completed at least 24 hours apart within a 2-week period. Testingwith the Wright device was performed as per the 2-minute tidal breathing protocol. The Solo study arm followed the same procedure except for a shorter inhalation time of 1minute. The provocative concentration ofmethacholine causing a 20% fall in FEV1 (PC20) and the methacholine PD20 were calculated following each methacholine challenge. Results: The geometric mean methacholine PC20 values for the Solo and the Wright differed statistically (0.65 mg/mL vs. 2.58 mg/mL, respectively, p < 0.00001) and clinically. Between-nebulizer geometric mean methacholine PD20 results are comparable by clinical standards [81.7 mu g (Solo) vs. 64.7 mu g (Wright)], although the slight difference in dose was statistically significant (p = 0.018). Conclusions: The comparability of PD20 values between the Solo and the Wright validates the importance of reporting airway responsiveness to methacholine in terms of dose and not concentration, as stressed in the latest testing guidelines. This finding along with several benefits associated with the Solo make it a promising nebulizer for performing MCT.
机构:
Air Liquide Sante Int, Med Gases Grp, Les Loges En Josas, FranceAir Liquide Sante Int, Med Gases Grp, Les Loges En Josas, France
Finlay, P.
Martin, A. R.
论文数: 0引用数: 0
h-index: 0
机构:
Amer Air Liquide, Delaware Res & Technol Ctr, Newark, DE USAAir Liquide Sante Int, Med Gases Grp, Les Loges En Josas, France
Martin, A. R.
Katz, I. M.
论文数: 0引用数: 0
h-index: 0
机构:
Air Liquide Sante Int, Med Gases Grp, Les Loges En Josas, France
Lafayette Coll, Easton, PA 18042 USAAir Liquide Sante Int, Med Gases Grp, Les Loges En Josas, France
Katz, I. M.
Vecellio, L.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Tours, Fac Med, INSERM 1100, CEPR,EA6305, Tours, FranceAir Liquide Sante Int, Med Gases Grp, Les Loges En Josas, France
Vecellio, L.
Caillibotte, G.
论文数: 0引用数: 0
h-index: 0
机构:
Air Liquide Sante Int, Med Gases Grp, Les Loges En Josas, FranceAir Liquide Sante Int, Med Gases Grp, Les Loges En Josas, France
Caillibotte, G.
Venegas, J. G.
论文数: 0引用数: 0
h-index: 0
机构:
MGH Harvard, Dept Anesthesia Bioengn, Boston, MA USAAir Liquide Sante Int, Med Gases Grp, Les Loges En Josas, France