Design and characterization of the XUV monochromator for ultrashort pulses at the ARTEMIS facility

被引:10
|
作者
Frassetto, F. [1 ]
Bonora, S. [1 ]
Villoresi, P. [1 ]
Poletto, L. [1 ]
Springate, E. [2 ]
Froud, C. A. [2 ]
Turcu, I. C. E. [2 ]
Langley, A. J. [2 ]
Wolff, D. S. [2 ]
Collier, J. L. [2 ]
Dhesi, S. S. [3 ]
Cavalleri, A. [4 ]
机构
[1] INFM, Lab UV & Xray Opt Res, Dept Informat Engn, Padua, Italy
[2] Rutherford Appleton Lab, Cent Laser Fac, Harwell, England
[3] Rutherford Appleton Lab, Diamond Light Source, Harwell, England
[4] Univ Oxford, Oxford, England
关键词
high-order harmonics; grating monochromator; off-plane mount;
D O I
10.1117/12.793009
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
ARTEMIS, a multi-partner and multidisciplinary project, will be a users-dedicated facility that will provide ultrashort XUV pulses through high harmonic generation in a gas target. This high repetition rate synchronized source will allow new science in research fields spanning from the material science to the molecular physics and chemistry. The XUV radiation is expected to cover the range 10 - 100 nm with an estimated photons flux up to 10 (11) photons/s per harmonic. In this work we present the design and characterization of the monochromator that will be used in the beamline for the experiments requiring wavelength and bandwidth selection. The working principle is based on a plane grating operated at grazing incidence in the off-plane mount. This geometry has been selected because of the high diffraction efficiency, expected to be about 30%. To cover the entire spectral range four gratings can be selected which span over different regions and with different spectral resolution. When the appropriate grating is chosen, the wavelength scanning is performed by rotating the grating around an axis passing through the grating center and parallel to the grooves direction. The off-plane mount requires the grating to be used in collimated light, consequently the optical scheme is completed by two toroidal mirrors, the first in front of the source that collimates the XUV radiation before the grating and the second after the grating to focalize the spectrally dispersed photons on the exit slit. Using a single grating, the configuration is not time-delay-compensated, nevertheless the time broadening (depending on the source divergence, the wavelength, and the grating) is less than 50 fs.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Characterization of partially coherent ultrashort XUV pulses
    Bourassin-Bouchet, Charles
    Couprie, Marie-Emmanuelle
    ADVANCES IN X-RAY FREE-ELECTRON LASERS INSTRUMENTATION III, 2015, 9512
  • [2] Characterization of Partially Coherent Ultrashort XUV Pulses
    Bourassin-Bouchet, Charles
    X-RAY LASERS 2016, 2018, 202 : 79 - 84
  • [3] A High Resolution XUV Grating Monochromator for the Spectral Selection of Ultrashort Harmonic Pulses
    Fabris, Nicola
    Miotti, Paolo
    Frassetto, Fabio
    Poletto, Luca
    APPLIED SCIENCES-BASEL, 2019, 9 (12):
  • [4] Single-shot temporal characterization of ultrashort XUV pulses
    Bourassin-Bouchet, Charles
    Chopineau, Ludovic
    Bomme, Cedric
    Quere, Fabien
    Sinyakova, Tatyana
    Dakroub, Laila
    Cubaynes, Denis
    Klisnick, Annie
    X-RAY LASERS AND COHERENT X-RAY SOURCES: DEVELOPMENT AND APPLICATIONS XIII, 2019, 11111
  • [5] XUV monochromator for novel application of ultrafast pulses
    Poletto, L.
    Villoresi, P.
    PROCEEDINGS OF INTERNATIONAL SYMPOSIUM ON BIOPHOTONICS, NANOPHOTONICS AND METAMATERIALS, 2006, : 377 - +
  • [6] Collinear generation of ultrashort UV and XUV pulses
    Bothschafter, E. M.
    Schiffrin, A.
    Yakovlev, V. S.
    Azzeer, A. M.
    Krausz, F.
    Ernstorfer, R.
    Kienberger, R.
    OPTICS EXPRESS, 2010, 18 (09): : 9173 - 9180
  • [7] INTERACTION OF INTENSE ULTRASHORT XUV PULSES WITH SILICON
    Sobierajski, R.
    Klinger, D.
    Jurek, M.
    Pelka, J. B.
    Juha, L.
    Chalupsky, J.
    Cihelka, J.
    Hajkova, V.
    Vysin, L.
    Jastrow, U.
    Stojanovic, N.
    Toleikis, S.
    Wabnitz, H.
    Krzywinski, J.
    Hau-Riege, S.
    London, R.
    DAMAGE TO VUV, EUV, AND X-RAY OPTICS II, 2009, 7361
  • [8] Photoionization of helium with ultrashort XUV laser pulses
    I. F. Barna
    J. M. Rost
    The European Physical Journal D - Atomic, Molecular, Optical and Plasma Physics, 2003, 27 : 287 - 290
  • [9] Photoionization of helium with ultrashort XUV laser pulses
    Barna, IF
    Rost, JM
    EUROPEAN PHYSICAL JOURNAL D, 2003, 27 (03): : 287 - 290
  • [10] A Novel monochromator for ultrashort soft X-ray pulses
    Brzhezinskaya, Maria
    Firsov, Alexander
    Holldack, Karsten
    Kachel, Torsten
    Mitzner, Rolf
    Pontius, Niko
    Stamm, Christian
    Schmidt, Jan-Simon
    Foehlisch, Alexander
    Erko, Alexei
    DAMAGE TO VUV, EUV, AND X-RAY OPTICS IV; AND EUV AND X-RAY OPTICS: SYNERGY BETWEEN LABORATORY AND SPACE III, 2013, 8777