A prospective, randomised comparison of single and three piece acrylic foldable intraocular lenses

被引:49
|
作者
Nejima, R
Miyata, K
Honbou, M
Tokunaga, T
Tanabe, T
Sato, M
Oshika, T
机构
[1] Univ Tsukuba, Inst Clin Med, Dept Ophthalmol, Tsukuba, Ibaraki 3058575, Japan
[2] Miyata Eye Hosp, Miyazaki, Japan
关键词
D O I
10.1136/bjo.2003.037663
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims: To compare the postoperative performance of single and three piece acrylic foldable intraocular lenses (IOLs). Methods: 20 patients underwent bilateral cataract surgery with a single piece SA30AL IOL in one eye and a three piece MA30BA IOL in the other eye. The eyes were randomly assigned to either a single or three piece lens. The amount of IOL decentration and tilt, area of anterior capsule opening, and degree of posterior capsule opacification were measured using the Scheimpflug anterior segment analysis system (Nidek EAS-1000). Visual acuity and contrast sensitivity were examined. Measurements were performed by masked examiners before and 1 day, 1 week, 1, 3, 6, and 18 months after surgery. Results: There were no significant differences between the two groups (p>0.05, paired t test) in the amount of IOL decentration, IOL tilt, area of anterior capsule opening, degree of posterior capsule opacification, best corrected visual acuity, and contrast sensitivity throughout the 18 month follow up period. Conclusion: The single and three piece acrylic foldable IOLs are equally stable in the eye after surgery.
引用
收藏
页码:746 / 749
页数:4
相关论文
共 50 条
  • [1] A clinical comparison of single-piece and three-piece truncated hydrophobic acrylic intraocular lenses
    Wallin, TR
    Hinckley, M
    Nilson, C
    Olson, RJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (04) : 614 - 619
  • [2] Anterior segment parameters: Comparison of 1-piece and 3-piece acrylic foldable intraocular lenses
    Behrouz, Mahmoud Jabbarvand
    Kheirkhah, Ahmad
    Hashemian, Hesam
    Nazari, Rahman
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10): : 1650 - 1655
  • [3] In vivo comparison of silicone and acrylic foldable intraocular lenses
    Smith, JH
    Hwang, DG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 2540 - 2540
  • [4] A simple technique of intraocular lenses explantation for single-piece foldable lenses
    Bhaumik, Arup
    Mitra, Santanu
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (12) : 1428 - 1430
  • [5] Foldable acrylic intraocular lenses in children
    Smith, DS
    Stager, DR
    Stager, DR
    Wilson, ME
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4517 - 4517
  • [6] Prospective intrapatient comparison of 6.0-millimeter optic single-piece and 3-piece hydrophobic acrylic foldable intralocular lenses
    Nejima, R
    Miyai, T
    Kataoka, Y
    Miyata, K
    Honbou, M
    Tokunaga, T
    Kawana, K
    Kiuchi, T
    Oshika, T
    OPHTHALMOLOGY, 2006, 113 (04) : 585 - 590
  • [7] Sulcus placement of single-piece acrylic intraocular lenses
    Mamalis, Nick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (08): : 1327 - 1328
  • [8] Nanosurface Properties of Foldable Acrylic Intraocular Lenses
    Goldberg, E. P.
    Martin, P.
    Lee, H. -Y.
    Elachchabi, A.
    Mentak, K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [9] Glistenings in the single-piece, hydrophobic, acrylic intraocular lenses
    Waite, Aaron
    Faulkner, Nathan
    Olson, Randall J.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (01) : 143 - 144
  • [10] The materials for intraocular lenses. Part III: acrylic foldable intraocular lenses
    Legeais, JM
    Werner, L
    Werner, L
    Renard, G
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2001, 24 (03): : 309 - 318