Non-scanning optical coherence tomography using off-axis interferometry with an angular-dispersion imaging scheme

被引:2
|
作者
Umetsu, E
Chan, KP
Tanno, N
机构
[1] Yamagata Univ, Grad Program Human Sensing & Funct Sensor Engn, Yonezawa, Yamagata 9928510, Japan
[2] Japan Sci & Technol Corp, Joint Res Project Yamagata Prefecture, Yamagata 9902473, Japan
关键词
biomedical imaging; optical coherence tomography; interferometric imaging; angular dispersion;
D O I
10.1007/s10043-002-0070-8
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a non-scanning approach for real-time optical coherence tomography (OCT). Our approach is based on an off-axis interferometer that laterally projects the time-of-flight or depth information of the sample onto an image sensor, To facilitate the use of an off-axis interferometer in OCT, an angular-dispersion imaging method has been developed. Theoretical analysis and experimental results are presented to demonstrate that this method is capable of demodulating the interferogram and thus permits a direct inspection of the depth-resolved image. Depth resolution and detection range of the present method are also studied.
引用
收藏
页码:70 / 74
页数:5
相关论文
共 50 条
  • [1] Non-Scanning Optical Coherence Tomography Using Off-Axis Interferometry with an Angular-Dispersion Imaging Scheme
    Eriko Umetsu
    Kin Pui Chan
    Naohiro Tanno
    Optical Review, 2002, 9 : 70 - 74
  • [2] Optical detection scheme for non-scanning optical coherence tomography based on off-axis interferometry
    Umetsu, E
    Akiba, M
    Chan, KP
    Tanno, N
    CLEO(R)/PACIFIC RIM 2001, VOL I, TECHNICAL DIGEST, 2001, : 352 - 353
  • [3] Non-scanning optical coherence tomography by an angular dispersion imaging method
    Umetsu, E
    Akiba, M
    Chan, KP
    Tanno, N
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2003, 42 (10B): : L1285 - L1287
  • [4] Optical tomography in coherent off-axis scanning holography
    Yao, Yongwei
    Zhang, Yaping
    Poon, Ting-Chung
    HOLOGRAPHY, DIFFRACTIVE OPTICS, AND APPLICATIONS XII, 2022, 12318
  • [5] Quantitative phase microscopy with off-axis optical coherence tomography
    Rinehart, Matthew T.
    Jaedicke, Volker
    Wax, Adam
    OPTICS LETTERS, 2014, 39 (07) : 1996 - 1999
  • [6] Off-axis optical coherence tomography imaging of the crystalline lens to reconstruct the gradient refractive index using optical methods
    de Castro, Alberto
    Birkenfeld, Judith
    Heilman, Bianca Maceo
    Ruggeri, Marco
    Arrieta, Esdras
    Parel, Jean-Marie
    Manns, Fabrice
    Marcos, Susana
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (07) : 3622 - 3634
  • [7] Optimized off-axis cylindrical mirror-focused line-scanning system for optical coherence tomography imaging applications
    Kamal, Mohammad
    Narayanswamy, Sivakumar
    Packirisamy, Muthukumaran
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (05)
  • [8] Off-axis low coherence digital holographic interferometry for quantitative phase imaging with an LED
    Guo, Rongli
    Wang, Fan
    Hu, Xiaoying
    Yang, Wenqian
    JOURNAL OF OPTICS, 2017, 19 (11)
  • [9] Low coherence off-axis digital holography based on scanning the optical path difference
    Deng, Li-Jun
    Yang, Yong
    Shi, Bing-Chuan
    Ma, Zhong-Hong
    Ge, Qi
    Zhai, Hong-Chen
    Guangzi Xuebao/Acta Photonica Sinica, 2014, 43 (10):
  • [10] Single-shot off-axis full-field optical coherence tomography
    Seromenho, Emmanuel Martins
    Marmin, Agathe
    Facca, Sybille
    Bahlouli, Nadia
    Perrin, Stephane
    Nahas, Amir
    APPLIED PHYSICS LETTERS, 2022, 121 (11)