The Electromagnetic Interference of Mobile Phones on the Function of a γ-Camera

被引:3
|
作者
Javadi, Hamid [1 ]
Azizmohammadi, Zahra [2 ]
Pashazadeh, Ali Mahmoud [3 ]
Asli, Isa Neshandar [2 ]
Moazzeni, Taleb [4 ]
Baharfar, Nastaran [2 ]
Shafiei, Babak [2 ]
Nabipour, Iraj [3 ]
Assadi, Majid [3 ]
机构
[1] Golestan Univ Med Sci, Golestan Res Ctr Gastroenterol & Hepatol, Gorgan, Iran
[2] Shahid Beheshti Univ Med Sci, Taleghani Hosp, Dept Nucl Med, Tehran, Iran
[3] Bushehr Univ Med Sci, Persian Gulf Nucl Med Res Ctr, Bushehr, Iran
[4] Univ Nevada, Dept Elect & Comp Engn, Las Vegas, NV 89154 USA
关键词
electromagnetic interference; mobile phones; gamma-camera; SPECT; COMMUNICATION;
D O I
10.1097/RLU.0000000000000355
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of the present study is to evaluate whether or not the electromagnetic field generated by mobile phones interferes with the function of a SPECT gamma-camera during data acquisition. Methods: We tested the effects of 7 models of mobile phones on 1 SPECT gamma-camera. The mobile phones were tested when making a call, in ringing mode, and in standby mode. The gamma-camera function was assessed during data acquisition from a planar source and a point source of Tc-99m with activities of 10 mCi and 3 mCi, respectively. A significant visual decrease in count number was considered to be electromagnetic interference ( EMI). Results: The percentage of induced EMI with the gamma-camera per mobile phone was in the range of 0% to 100%. The incidence of EMI was mainly observed in the first seconds of ringing and then mitigated in the following frames. Conclusions: Mobile phones are portable sources of electromagnetic radiation, and there is interference potential with the function of SPECT gamma-cameras leading to adverse effects on the quality of the acquired images.
引用
收藏
页码:232 / 236
页数:5
相关论文
共 50 条
  • [1] The electromagnetic interference of mobile phones on the function of a gamma camera
    Assadi, M.
    Javadi, H.
    Azizmohammadi, Z.
    Pashazadeh, A. Mahmoud
    Moazzeni, T.
    Baharfar, N.
    Shafiei, B.
    Delavari, S.
    Nabipour, I.
    Babaei, A.
    Asli, I. Neshandar
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S299 - S299
  • [2] Electromagnetic interference of pacemakers by mobile phones
    Irnich, W
    Batz, L
    Muller, R
    Tobisch, R
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (10): : 1431 - 1446
  • [4] Interference of pacemaker function by mobile phones
    Maity, AK
    Roychoudhury, GK
    Das Biswas, A
    Chatterjee, SS
    Biswas, A
    Biswas, P
    Mitra, K
    VI ASIAN-PACIFIC SYMPOSIUM ON CARDIAC PACING AND ELECTROPHYSIOLOGY, 1997, : 49 - 53
  • [5] Mobile Phones Electromagnetic Interference in Medical Environments: a Review
    Fernandez-Chimeno, Mireya
    Silva, Ferran
    2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC 2010), 2010, : 311 - 316
  • [6] Electromagnetic interference of mobile phones: insight into heart rate variability
    Mert, Kadir Ugur
    Dural, Muhammet
    Mert, Gurbet Ozge
    Iskenderov, Kemal
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2017, 17 (03): : 248 - 248
  • [7] Electromagnetic interference with infusion pumps from GSM mobile phones
    Calcagnini, G
    Floris, M
    Censi, F
    Cianfanelli, P
    Scavino, G
    Bartolini, P
    HEALTH PHYSICS, 2006, 90 (04): : 357 - 360
  • [8] Electromagnetic interference to infusion pumps from GSM mobile phones
    Calcagnini, G
    Bartolini, P
    Floris, M
    Triventi, M
    Cianfanelli, P
    Scavino, G
    Proietti, L
    Barbaro, V
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3515 - 3518
  • [9] Modeling of electromagnetic interference to an implanted cardiac pacemaker due to mobile phones
    Wang, JQ
    Fujiwara, O
    2000 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1 AND 2, SYMPOSIUM RECORD, 2000, : 209 - 212
  • [10] INTERFERENCE OF MOBILE PHONES WITH FUNCTION OF IMPLANTED PACEMAKERS - HOW SIGNIFICANT IS THE RISK
    MEISEL, E
    KOPSCEK, H
    KLINGHAMMER, L
    DANIEL, WG
    CIRCULATION, 1995, 92 (08) : 3546 - 3546