A Comparison of Internet Monitoring with Continuous Glucose Monitoring in Insulin-Requiring Type 2 Diabetes Mellitus (Withdrawn Publication)

被引:10
|
作者
Tildesley, Hugh D. [1 ,2 ]
Wright, Anthony M. [3 ]
Chan, Jeremy H. M. [4 ]
Mazanderani, Adel B. [5 ]
Ross, Stuart A. [6 ]
Tildesley, Hamish G. [7 ]
Lee, Augustine M. [2 ]
Tang, Tricia S. [2 ]
White, Adam S. [1 ,2 ]
机构
[1] St Pauls Hosp, Dept Endocrinol & Metab, Vancouver, BC V6Z 1Y6, Canada
[2] Univ British Columbia, Vancouver, BC V5Z 1M9, Canada
[3] Univ Victoria, Victoria, BC, Canada
[4] Vanderbilt Univ, Sch Med, Nashville, TN 37212 USA
[5] St Georges Univ, St Georges, Grenada
[6] Univ Calgary, Calgary, AB, Canada
[7] Dartmouth Coll, Hanover, NH 03755 USA
关键词
Internet-based glucose monitoring; real-time continuous glucose monitoring; remote monitoring; type; 2; diabetes; BLOOD-GLUCOSE;
D O I
10.1016/j.jcjd.2013.05.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare the effects of real-time continuous glucose monitoring (RT-CGM) and an Internet blood glucose monitoring system (IBGMS) on glycated hemoglobin levels in patients with type 2 diabetes mellitus treated with insulin. Methods: Fifty-seven patients with type 2 diabetes treated with insulin were assigned randomly to 1 of 2 groups. Group 1 had the results of their self-monitoring of blood glucose level monitored biweekly using an IBGMS. Group 2 used RT-CGM and were monitored biweekly. Both groups used a secure website to upload data and to receive feedback from their endocrinologist. A1C and laboratory test results were collected at 0, 3 and 6 months. Results: The baseline parameters were not significantly different. After a 6-month follow-up period, both IBGMS and RT-CGM showed significant within-group improvements in A1C level. In the IBGMS group, the A1C level decreased from 8.79%+/- 1.25% to 7.96%+/- 1.30% (p<0.05). The RT-CGM group decreased from 8.80%+/- 1.37% to 7.49%+/- 0.70% (p<0.001). IBGMS and RT-CGM did not show significantly different A1C levels at baseline, 3 and 6 months (p>0.05). Conclusions: The use of both IBGMS and RT-CGM significantly improved A1C levels in patients with type 2 diabetes treated with insulin in a randomized trial over a 6-month period. There were no significant differences in A1C values between groups after 6 months. (C) 2013 Canadian Diabetes Association
引用
收藏
页码:305 / 308
页数:4
相关论文
共 50 条
  • [1] A Comparison of Internet Monitoring With Continuous Glucose Monitoring in Insulin-Requiring Type 2 DM
    Tildesley, Hugh D.
    White, Adam S.
    Wright, Anthony M.
    Chan, Jeremy H. S.
    Mazanderani, Adel B.
    Tang, Tricia
    Ross, Stuart A.
    Lee, Augustine M.
    Tildesley, Hamish G.
    [J]. DIABETES, 2013, 62 : A229 - A229
  • [2] Glucose monitoring in women with insulin-requiring gestational diabetes mellitus
    de Veciana, M
    [J]. DIABETES-METABOLISM REVIEWS, 1998, 14 : S25 - S30
  • [3] Role of Continuous Glucose Monitoring in Insulin-Requiring Patients with Diabetes
    Welsh, John B.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 : 42 - 49
  • [4] Self-monitoring of blood glucose in insulin-requiring type 2 diabetes
    Naik, Ramachandra G.
    Ellis, Samuel L.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2008, 10 : S67 - S71
  • [5] The effect of professional continuous glucose monitoring on glycaemic control and hypoglycaemia in insulin-requiring gestational diabetes mellitus
    Paramasivam, S. S.
    Tan, A. T. B.
    Chan, S. P.
    Tan, P. C.
    Omar, S. Z.
    Ratnasingam, J.
    Ibrahim, L.
    Lim, L. L.
    Razak, R. A.
    Shah, F. Z. M.
    Vethakkan, S. R.
    [J]. DIABETOLOGIA, 2014, 57 : S449 - S449
  • [6] The effect of professional continuous glucose monitoring on glycaemic control and hypoglycaemia in insulin-requiring gestational diabetes mellitus
    Paramasivam, S. S.
    Tan, A. T. B.
    Chan, S. P.
    Chinna, K.
    Ratnasingam, J.
    Ibrahim, L.
    Lim, L. L.
    Tan, P.
    Omar, S. Z.
    Vethakkan, S. R.
    [J]. DIABETOLOGIA, 2015, 58 : S74 - S75
  • [7] Early health technology assessment: Continuous glucose monitoring for the maintenance of glycemic control in insulin-requiring type 1 diabetes
    Marangos, PJ
    Seybold, P
    Papatheofanis, FJ
    [J]. VALUE IN HEALTH, 2006, 9 (03) : A31 - A31
  • [8] Real time continuous glucose monitoring in high-risk people with insulin-requiring type 2 diabetes: A randomised controlled trial
    Lever, Claire S.
    Williman, Jonathan A.
    Boucsein, Alisa
    Watson, Antony
    Sampson, Rachael S.
    Sergel-Stringer, Oscar T.
    Keesing, Celeste
    Chepulis, Lynne
    Wheeler, Benjamin J.
    de Bock, Martin I.
    Paul, Ryan G.
    [J]. DIABETIC MEDICINE, 2024, 41 (08)
  • [9] Combination insulin and sulfonylurea therapy in insulin-requiring type 2 diabetes mellitus
    Feinglos, MN
    Thacker, CR
    Lobaugh, B
    DeAtkine, DD
    McNeill, DB
    English, JS
    Bursey, DL
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 1998, 39 (03) : 193 - 199
  • [10] Continuous glucose monitoring in type 1 diabetes mellitus
    Pavlicek, Vojtech
    [J]. DIABETOLOGE, 2019, 15 (08): : 744 - 746