Characterization of two modes in a dielectric barrier discharge probe by optical emission spectroscopy and time-of-flight mass spectrometry

被引:17
|
作者
Bierstedt, Andreas [1 ]
Panne, Ulrich [1 ,2 ]
Rurack, Knut [1 ]
Riedel, Jens [1 ]
机构
[1] Fed Inst Mat Res & Testing, BAM, D-12489 Berlin, Germany
[2] Humboldt Univ, Dept Chem, D-12489 Berlin, Germany
关键词
TEMPERATURE PLASMA PROBE; ATMOSPHERIC-PRESSURE; AMBIENT IONIZATION; ION FORMATION; OPTIMIZATION; MOLECULES; MERCURY; AIR;
D O I
10.1039/c5ja00332f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Among the large number of new ambient ionization schemes in the last few years, dielectric barrier discharge (DBD) has witnessed special attention. In this contribution a versatile dual mode DBD is introduced and characterized by means of optical emission spectroscopy and time-of-flight mass spectrometry. A direct comparison of the individual results from spectroscopy, spectrometry and transient current/voltage consumption gives evidence for the existence of two individual operational mechanisms. The first is driven by rapid transient changes in the potential difference between the two electrodes over time (usually denoted as the homogeneous mode), while the second is caused at high static potential differences (leading to filamentary discharges). The transient versus steady-state characteristics of the individual discharge origin suggest the driving force for the current flow to be inductive and capacitive, respectively. In most cases of dielectric barrier plasmas both discharge types coexist as competitive ion formation channels, however, detailed plasma characteristics of DBDs operated under different conditions allow for a clear distinction of the individual contributions. In this way, two characteristic product channels for the ionization of ambient water could be observed resulting in the generation of either preferentially protonated water clusters or ammonium water clusters. Careful tuning of the operation parameters of the discharge device allows an operation predominated by either of the two modes. As a consequence, facile switching into the desired operational mode results in either protonated molecules or ammoniated molecules of the analyte. Plasma characteristics for both moieties were evaluated and cross-correlated on the basis of several factors including: the production of reagent ions, the individual appearance of current/voltage profiles, UV/Vis spectroscopy, voltage and flux dependence and the individual response to test compounds. Although the filamentary mode has been already discussed in the literature to induce fragmentation processes, no experimental evidence for analyte dissociation could be found in the case of the test compounds used.
引用
收藏
页码:2496 / 2506
页数:11
相关论文
共 50 条
  • [1] Pulsed glow discharge time-of-flight mass spectrometry
    Harrison, WW
    Hang, W
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) : 835 - 840
  • [2] Pulsed Radiofrequency Glow Discharge Time-of-Flight Mass Spectrometry for Nanostructured Materials Characterization
    Bustelo, Marta
    Fernandez, Beatriz
    Pisonero, Jorge
    Pereiro, Rosario
    Bordel, Nerea
    Vega, Victor
    Prida, Victor M.
    Sanz-Medel, Alfredo
    ANALYTICAL CHEMISTRY, 2011, 83 (01) : 329 - 337
  • [3] QUANTITATIVE MICROANALYSIS BY TIME-OF-FLIGHT LASER PROBE MASS-SPECTROMETRY
    ELOY, JF
    SCANNING ELECTRON MICROSCOPY, 1986, 1986 : 1243 - 1253
  • [4] Polymer screening by radiofrequency glow discharge time-of-flight mass spectrometry
    Lobo, L.
    Tuccitto, N.
    Bordel, N.
    Pereiro, R.
    Pisonero, J.
    Licciardello, A.
    Tempez, A.
    Chapon, P.
    Sanz-Medel, A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (08) : 2863 - 2869
  • [5] Polymer screening by radiofrequency glow discharge time-of-flight mass spectrometry
    L. Lobo
    N. Tuccitto
    N. Bordel
    R. Pereiro
    J. Pisonero
    A. Licciardello
    A. Tempez
    P. Chapon
    A. Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2010, 396 : 2863 - 2869
  • [6] Time-of-flight mass spectrometry with a pulsed glow discharge ionization source
    Steiner, RE
    Lewis, CL
    King, FL
    ANALYTICAL CHEMISTRY, 1997, 69 (09) : 1715 - 1721
  • [7] Time-of-flight mass analyser for anion mass spectrometry and anion photoelectron spectroscopy
    Boesl, U
    Bässmann, C
    Käsmeier, R
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 206 (03) : 231 - 244
  • [8] Characterization of the chicken telokin heterogeneity by time-of-flight mass spectrometry
    Rusconi, F
    Potier, MC
    LeCaer, JP
    Schmitter, JM
    Rossier, J
    BIOCHEMISTRY, 1997, 36 (36) : 11021 - 11026
  • [9] Diagnosis of the electron temperature in dielectric barrier discharge by optical emission spectroscopy
    Ran, JX
    Dong, LF
    Mao, ZG
    Liu, SH
    Optical Design and Testing II, Pts 1 and 2, 2005, 5638 : 561 - 566
  • [10] Impact of homogeneous and filamentary discharge modes on the efficiency of dielectric barrier discharge ionization mass spectrometry
    Meyer, Cordula
    Mueller, Saskia
    Gilbert-Lopez, Bienvenida
    Franzke, Joachim