EVALUATION AND COMPARISON OF SPRAY EQUIPMENT FOR INDOOR RESIDUAL SPRAYING

被引:0
|
作者
Correa-Morales, Fabian [1 ]
Dunbar, Mike W. [2 ]
Dzul-Manzanilla, Felipe [2 ]
Medina-Barreiro, Anuar [3 ]
Morales-Rios, Evaristo [3 ]
Bibiano-marin, Wilbert [3 ]
Che-Mendoza, Azael [3 ]
Manrique-Saide, Pablo [3 ]
Vazquez-Prokopec, Gonzalo M. [2 ]
机构
[1] Secretaria Salud Mexico, Ctr Nacl Programas Preventivos & Control Enfermed, Ciudad De Mexico 11800, Mexico
[2] Emory Univ, Dept Environm Sci, Atlanta, GA 30322 USA
[3] Univ Autonoma Yucatan, Unidad Colaborat Bioensayos Entomol, Merida 97100, Mexico
关键词
Aedes aegypti; hand compression pump; insecticide; spray equipment;
D O I
10.2987/18-6810.1
中图分类号
Q96 [昆虫学];
学科分类号
摘要
The World Health Organization (WHO) has recently recommended indoor residual spraying (IRS) as part of a vector control strategy to combat Aedes-borne diseases, including dengue, chikungunya, and Zika viruses. Hand compression sprayers have been used in malaria prevention and control programs worldwide since the 1950s and are a standard for IRS application. However, there are technological advances that should be considered to improve IRS application (e.g., flow-control valves, rechargeable-battery equipment, reduced-drift nozzles, etc.), particularly if interventions are performed in urban areas to target Aedes aegypti. Using WHO guidelines, we contrasted technical characteristics of potential IRS equipment including hand compression sprayers (Hudson X-pert, Goizper IK Vector Control Super), rechargeable-battery sprayers (Solo 416, Birchmeier REC 15ABZ, Hudson NeverPump), and motorized sprayers (Honda WJR 2525, Kawashima AK35GX). Measurements included flow rate, droplet size, battery/fuel life, and technical/physical characteristics. Flow rate, the most important parameter, of the Hudson X-pert was stabilized at 550 ml/min by the use of a control flow valve (CFV). The IK Vector Control Super had integrated CFVs and produced a similar flow as the Hudson X-pert. Rechargeable-battery equipment provided consistent flow as well as negligible noise. Motorized sprayers also produced consistent flow, but their weight, high noise pollution when used indoors, and high engine temperature made them highly unpleasant for technicians. We identify alternatives to the more traditional hand compression Hudson X-pert sprayer with technical and operational considerations for performing IRS.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 50 条
  • [1] COMPARISON OF INDOOR RESIDUAL SPRAY EQUIPMENT FOR MALARIA CONTROL IN LIBERIA
    Obenauer, Peter J.
    Farooq, Mohammad
    Knapp, Jennifer A.
    Yans, Matthew W.
    Santana, Luis A.
    Richardson, Alec G.
    Nador, Nadoris N.
    Diclaro, Joseph W., II
    JOURNAL OF THE AMERICAN MOSQUITO CONTROL ASSOCIATION, 2015, 31 (04) : 388 - 391
  • [2] Indoor residual spraying for preventing malaria
    Pluess, Bianca
    Tanser, Frank C.
    Lengeler, Christian
    Sharp, Brian L.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2010, (04):
  • [3] Indoor residual spraying for prevention of malaria
    N'Guessan, Raphael
    Rowland, Mark
    LANCET INFECTIOUS DISEASES, 2012, 12 (08): : 581 - 582
  • [4] Wall-type and indoor residual spraying application quality affect the residual efficacy of indoor residual spray against wild malaria vector in southwest Ethiopia
    Desalegn, Zerihun
    Wegayehu, Teklu
    Massebo, Fekadu
    MALARIA JOURNAL, 2018, 17
  • [5] Wall-type and indoor residual spraying application quality affect the residual efficacy of indoor residual spray against wild malaria vector in southwest Ethiopia
    Zerihun Desalegn
    Teklu Wegayehu
    Fekadu Massebo
    Malaria Journal, 17
  • [6] Indoor low-volume spray trials: Handheld equipment evaluation
    Brown, JR
    Williams, DC
    Gwinn, TA
    Presley, SH
    Beavers, GM
    JOURNAL OF THE AMERICAN MOSQUITO CONTROL ASSOCIATION, 2002, 18 (03) : 232 - 235
  • [7] INDOOR RESIDUAL SPRAYING OF DDT FOR MALARIA CONTROL
    Chen, Hsi Hsuan
    Chen, Anthony L-T
    AMERICAN JOURNAL OF PUBLIC HEALTH, 2009, 99 (08) : 1350 - 1351
  • [8] USING MULTI CRITERIA EVALUATION TO IDENTIFY PRIORITY AREA FOR INDOOR RESIDUAL SPRAYING, MADAGASCAR
    Rakotoarison, Anthonio H.
    Rasamimalala, Mampionona
    Rakotondramanga, Jean-Marius
    Ramiranirina, Brune
    Franchard, Thierry
    Kapesa, Laurent
    Razafindrakoto, Jocelyn
    Baril, Laurence
    Piola, Patrice
    Rakotomanana, Fanjasoa
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2017, 97 (05): : 330 - 331
  • [9] User friendliness, efficiency & spray quality of stirrup pumps versus hand compression pumps for indoor residual spraying
    Kumar, Vijay
    Kesari, Shreekant
    Chowdhury, Rajib
    Kumar, Sanjiv
    Sinha, Gunjan
    Hussain, Saddam
    Huda, M. Mamun
    Kroeger, Axel
    Das, Pradeep
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2013, 138 : 239 - 243
  • [10] Evaluation of the residual efficacy of indoor residual spraying with bendiocarb (FICAM WP 80) in six health districts in Senegal
    Cheikh Lo
    Abdoulaye Kane Dia
    Ibrahima Dia
    El Hadji Amadou Niang
    Lassana Konaté
    Ousmane Faye
    Malaria Journal, 18