Technology in Rehabilitation: Evaluating the Single Leg Squat Exercise with Wearable Inertial Measurement Units

被引:39
|
作者
Whelan, Darragh F. [1 ,2 ]
O'Reilly, Martin A. [1 ,2 ]
Ward, Tomas E. [3 ]
Delahunt, Eamonn [2 ]
Caulfield, Brian [1 ,2 ]
机构
[1] Univ Coll Dublin, Insight Ctr Data Analyt, Dublin, Ireland
[2] Univ Coll Dublin, Sch Publ Hlth Physiotherapy & Sports Sci, Dublin, Ireland
[3] Maynooth Univ, Insight Ctr Data Analyt, Maynooth, Kildare, Ireland
基金
爱尔兰科学基金会;
关键词
Exercise therapy; biomedical technology; lower extremity; physical therapy speciality; inertial measurement units; MOVEMENT QUALITY; AGREEMENT;
D O I
10.3414/ME16-02-0002
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Background: The single leg squat (SLS) is a common lower limb rehabilitation exercise. It is also frequently used as an evaluative exercise to screen for an increased risk of lower limb injury. To date athlete/patient SLS technique has been assessed using expensive laboratory equipment or subjective clinical judgement; both of which are not without shortcomings. Inertial measurement units (IMUs) may offer a low cost solution for the objective evaluation of athlete/patient SLS technique. Objectives: The aims of this study were to determine if in combination or in isolation IMUs positioned on the lumbar spine, thigh and shank are capable of: (a) distinguishing between acceptable and aberrant SLS technique; (b) identifying specific deviations from acceptable SLS technique. Methods: Eighty-three healthy volunteers participated (60 males, 23 females, age: 24.68 +/- 4.91 years, height: 1.75 +/- 0.09 m, body mass: 76.01 +/- 13.29 kg). All participants performed 10 SLSs on their left leg. IMUs were positioned on participants' lumbar spine, left shank and left thigh. These were utilized to record tri-axial accelerometer, gyroscope and magnetometer data during all repetitions of the SLS. SLS technique was labelled by a Chartered Physiotherapist using an evaluation framework. Features were extracted from the labelled sensor data. These features were used to train and evaluate a variety of random-forests classifiers that assessed SLS technique. Results:A three IMU system was moderately successful in detecting the overall quality of SLS performance (77% accuracy, 77% sensitivity and 78% specificity). A single IMU worn on the shank can complete the same analysis with 76% accuracy, 75% sensitivity and 76% specificity. Single sensors also produce competitive classification scores relative to multi-sensor systems in identifying specific deviations from acceptable SLS technique. Conclusions:A single IMU positioned on the shank can differentiate between acceptable and aberrant SLS technique with moderate levels of accuracy. It can also capably identify specific deviations from optimal SLS performance. IMUs may offer a low cost solution for the objective evaluation of SLS performance. Additionally, the classifiers described may provide useful input to an exercise biofeedback application.
引用
收藏
页码:88 / 94
页数:7
相关论文
共 50 条
  • [1] Classification of Squat Quality with Inertial Measurement Units in the Single Leg Squat Mobility Test
    Kianifar, Rezvan
    Lee, Alex
    Raina, Sachin
    Kulic, Dana
    [J]. 2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 6273 - 6276
  • [2] Technology in Rehabilitation: Comparing Personalised and Global Classification Methodologies in Evaluating the Squat Exercise with Wearable IMUs
    Whelan, Darragh F.
    O'Reilly, Martin A.
    Ward, Tomas E.
    Delahunt, Eamonn
    Caulfield, Brian
    [J]. METHODS OF INFORMATION IN MEDICINE, 2017, 56 (05) : 361 - 369
  • [3] Evaluating Squat Performance with a Single Inertial Measurement Unit
    O'Reilly, Martin
    Whelan, Darragh
    Chanialidis, Charalampos
    Friel, Nial
    Delahunt, Eamonn
    Ward, Tomas
    Caulfield, Brian
    [J]. 2015 IEEE 12TH INTERNATIONAL CONFERENCE ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS (BSN), 2015,
  • [4] Evaluating Rehabilitation Exercise Performance Using a Single Inertial Measurement Unit
    Giggins, Oonagh
    Kelly, Daniel
    Caulfield, Brian
    [J]. PROCEEDINGS OF THE 2013 7TH INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING TECHNOLOGIES FOR HEALTHCARE AND WORKSHOPS (PERVASIVEHEALTH 2013), 2013, : 49 - 56
  • [5] Children's Rehabilitation with Humanoid Robots and Wearable Inertial Measurement Units
    Guneysu, Arzu
    Arnrich, Bert
    Ersoy, Cem
    [J]. PROCEEDINGS OF THE 2015 9TH INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING TECHNOLOGIES FOR HEALTHCARE (PERVASIVEHEALTH), 2015, : 249 - 252
  • [6] THE BIOMECHANICAL CHALLENGE OF SINGLE LEG SQUAT EXERCISE AND IMPLICATIONS FOR EXERCISE PROGRESSION
    Button, K.
    Roos, P. E.
    Rimmer, P.
    van Deursen, R. W.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2014, 22 : S111 - S111
  • [7] Classification of deadlift biomechanics with wearable inertial measurement units
    O'Reilly, Martin A.
    Whelan, Darragh F.
    Ward, Tomas E.
    Delahunt, Eamonn
    Caulfield, Brian M.
    [J]. JOURNAL OF BIOMECHANICS, 2017, 58 : 155 - 161
  • [8] Synchronisation of wearable inertial measurement units based on magnetometer data
    Spilz, Andreas
    Munz, Michael
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2023, 68 (03): : 263 - 273
  • [9] Reliability of Evaluating the Single Leg Squat Using Multiple Assessment Methods
    Dartt, Carolyn
    De La Motte, Sarah
    Deuster, Patricia
    Gribbin, Timothy
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 513 - 513
  • [10] A least-squares identification algorithm for estimating squat exercise mechanics using a single inertial measurement unit
    Bonnet, Vincent
    Mazza, Claudia
    Fraisse, Philippe
    Cappozzo, Aurelio
    [J]. JOURNAL OF BIOMECHANICS, 2012, 45 (08) : 1472 - 1477