REQUIREMENTS ON TENDONS FOR EXTRADOSED BRIDGES

被引:0
|
作者
Glaeser, Christian [1 ]
Brand, Werner [1 ]
机构
[1] DYWIDAG Syst Int GmbH, Reg Headquarter Europe, Siemensstr 8, D-85716 Unterschleissheim, Germany
关键词
Extradosed; Tendon; Stay Cable; Durability; Testing;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Extradosed bridges are getting more popular in all countries. After a successful start in Japan also in Europe a lot of projects are realized. For extradosed bridges the tendon layout is similar to cable stayed bridges, but due to the increased stiffness of the superstructure and the flat inclination of the tendon the actions on the tendons (especially fatigue loads) are much lower. Special care has to be taken on the properties of the tendons used. Due to the environmental exposure especially for the corrosion protection and leak tightness identical requirements are essential for both bridge types. On basis of theoretical considerations it was verified that a stay cable tested according to fib-bulletin 30 also fulfills the requirements for extradosed tendons. As usually the fatigue resistance for external tendons is only shown for a stress range of Delta sigma=80 MPa, fatigue tests with higher stress range have to be performed on external tendons to guarantee the usage in extradosed bridges. In the article the requirements regarding static and fatigue behaviour, the transfer of load differences to the pylon at the saddle, the exchangeability of tendons and durability aspects are discussed.
引用
收藏
页码:439 / 442
页数:4
相关论文
共 50 条
  • [42] Vibrational tension measurement of external tendons in segmental posttensioned bridges
    Sagues, A. A.
    Kranc, S. C.
    Eason, T. G.
    JOURNAL OF BRIDGE ENGINEERING, 2006, 11 (05) : 582 - 589
  • [43] Polyethylene duct cracking on posttensioning tendons in Florida segmented bridges
    Suarez, Jorge
    Zhang, Jingyu
    Hsuan, Grace
    Hartt, William
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2006, 18 (04) : 581 - 587
  • [44] DEFORMATION OF SEGMENTAL POSTTENSIONED PRECAST BRIDGES AS A RESULT OF CORROSION OF THE TENDONS
    WOODWARD, RJ
    WILSON, DLS
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 1-DESIGN AND CONSTRUCTION, 1991, 90 : 397 - 419
  • [45] Tendons with Plastic Ducts for Bridges without Mild Steel Reinforcement
    Berger, Johannes
    Kollegger, Johann
    BETON- UND STAHLBETONBAU, 2009, 104 (06) : 349 - 356
  • [46] SQUID system for magnetic inspection of prestressed tendons on concrete bridges
    Krause, HJ
    Wolf, W
    Glaas, W
    Zimmermann, E
    Faley, MI
    Sawade, G
    Neudert, G
    Gampe, U
    Krieger, J
    INSIGHT, 2001, 43 (07) : 458 - 461
  • [47] Damage Detection in External Tendons of Post-Tensioned Bridges
    Tabiatnejad, Dariya
    Tabiatnejad, Bardia
    Dolati, Seyed Saman Khedmatgozar
    Mehrabi, Armin
    INFRASTRUCTURES, 2024, 9 (07)
  • [48] REALISTIC REQUIREMENTS FOR UNBONDED POST-TENSIONING TENDONS
    BONDY, KB
    JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1970, 15 (01): : 50 - &
  • [49] REALISTIC REQUIREMENTS FOR UNBONDED POST-TENSIONING TENDONS
    BONDY, KB
    KOURKENE, JP
    JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1971, 16 (01): : 63 - &
  • [50] Optimization for cable-force of extradosed cable-stayed bridges based on minimal cost principle
    Chen, Cong-Chun
    Gongcheng Lixue/Engineering Mechanics, 2012, 29 (05): : 141 - 146