Optimal Adaptive Statistical Iterative Reconstruction Percentage in Dual-energy Monochromatic CT Portal Venography

被引:14
|
作者
Zhao, Liqin [1 ]
Winklhofer, Sebastian [2 ]
Yang, Zhenghan [1 ]
Wang, Keyang [1 ]
He, Wen [1 ]
机构
[1] Capital Med Univ, Beijing Friendship Hosp, Dept Radiol, 95 Yong An Rd, Beijing 100050, Peoples R China
[2] Univ Zurich Hosp, Inst Diagnost & Intervent Radiol, CH-8091 Zurich, Switzerland
基金
中国国家自然科学基金;
关键词
Dual-energy CT; ASIR; key; BMI; Portal vein; FILTERED BACK-PROJECTION; ROUTINE-DOSE CT; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; OPTIMAL CONTRAST; GASTRIC VARICES; ANGIOGRAPHY; EXPERIENCE; REDUCTION; ABDOMEN;
D O I
10.1016/j.acra.2015.11.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The aim of this article was to study the influence of different adaptive statistical iterative reconstruction (ASIR) percentages on the image quality of dual-energy computed tomography (DECT) portal venography in portal hypertension patients. Materials and Methods: DECT scans of 40 patients with cirrhosis (mean age, 56 years) at the portal venous phase were retrospectively analyzed. Monochromatic images at 60 and 70 keV were reconstructed with four ASIR percentages: 0%, 30%, 50%, and 70%. Computed tomography (CT) numbers of the portal veins (PVs), liver parenchyma, and subcutaneous fat tissue in the abdomen were measured. The standard deviation from the region of interest of the liver parenchyma was interpreted as the objective image noise (IN). The contrast-noise ratio (CNR) between PV and liver parenchyma was calculated. The diagnostic acceptability (DA) and sharpness of PV margins were obtained using a 5-point score. The IN, CNR, DA, and sharpness of PV were compared among the eight groups with different keV + ASIR level combinations. Results: The IN, CNR, DA, and sharpness of PV of different keV + ASIR groups were all statistically different (P < 0.05). In the eight groups, the best and worst CNR were obtained in the 60 keV + 70% ASIR and 70 keV + 0% ASIR (filtered back-projection [FBP]) combination, respectively, whereas the largest and smallest objective IN were obtained in the 60 keV + 0% ASIR (FBP) and 70 keV + 70% combination. The highest DA and sharpness values of PV were obtained at 50% ASIR for 60 keV. Conclusions: An optimal ASIR percentage (50%) combined with an appropriate monochromatic energy level (60 keV) provides the highest DA in portal venography imaging, whereas for the higher monochromatic energy (70 keV) images, 30% ASIR provides the highest image quality, with less IN than 60 keV with 50% ASIR.
引用
收藏
页码:337 / 343
页数:7
相关论文
共 50 条
  • [1] Iodine load reduction in dual-energy spectral CT portal venography with low energy images combined with adaptive statistical iterative reconstruction
    Han, Dong
    Chen, Xiaoxia
    Lei, Yuxin
    Ma, Chunling
    Zhou, Jieli
    Xiao, Yingcong
    Yu, Yong
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1100):
  • [2] Dual-Energy Spectral Computed Tomography With Adaptive Statistical Iterative Reconstruction for Improving Image Quality of Portal Venography
    Wang, Weibing
    Huang, Jinbai
    Wang, Ai
    Li, Yun
    Peng, Jie
    Hu, Xinjie
    Liu, Yingjun
    Zhang, Haiyan
    Li, Xiaohu
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 954 - 958
  • [3] Dual Energy CT (DECT) Monochromatic Imaging: Added Value of Adaptive Statistical Iterative Reconstructions (ASIR) in Portal Venography
    Zhao, Liqin
    Winklhofer, Sebastian
    Jiang, Rong
    Wang, Xinlian
    He, Wen
    PLOS ONE, 2016, 11 (06):
  • [4] Clinical value of dual-energy spectral imaging with adaptive statistical iterative reconstruction for reducing contrast medium dose in CT portal venography: in comparison with standard 120-kVp imaging protocol
    Ma, Chun-Ling
    Chen, Xiao-Xia
    Lei, Yu-Xin
    Zhang, Xi-Rong
    Jia, Yong-Jun
    Tian, Xin
    Tian, Qian
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1062):
  • [5] Dual-energy CT Portal Venography: Clinical Application Values and Future Opportunities
    Peng, Yu Yang
    Yan, Jing
    Li, Yu Ru
    Lu, Xiao Rui
    Wang, Lu Yao
    Jia, Ping Fan
    Guo, Xing
    CURRENT MEDICAL IMAGING, 2024, 20
  • [6] An iterative reconstruction method based on monochromatic images for dual energy CT
    Zhang, Weibin
    Zhao, Shusen
    Pan, Huiying
    Zhao, Yunsong
    Zhao, Xing
    MEDICAL PHYSICS, 2021, 48 (10) : 6437 - 6452
  • [7] Motion-compensated scheme for sequential scanned statistical iterative dual-energy CT reconstruction
    Ge, Tao
    Liao, Rui
    Medrano, Maria
    Politte, David G.
    Whiting, Bruce R.
    Williamson, Jeffrey F.
    O'Sullivan, Joseph A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (14):
  • [8] Iterative Reconstruction for Quantitative Tissue Decomposition in Dual-Energy CT
    Magnusson, Maria
    Malusek, Alexandr
    Muhammad, Arif
    Carlsson, Gudrun Alm
    IMAGE ANALYSIS: 17TH SCANDINAVIAN CONFERENCE, SCIA 2011, 2011, 6688 : 479 - 488
  • [9] Optimal Contrast of Computed Tomography Portal Venography Using Dual-Energy Computed Tomography
    Wang, Qi
    Shi, Gaofeng
    Liu, Xiang
    Wu, Runze
    Wang, Shijie
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (02) : 142 - 148
  • [10] The optimal energy level of virtual monochromatic imaging in dual-energy CT arthrography of the wrist
    Chung, Bo Mi
    Lee, Guen Young
    Kim, Sujin
    BRITISH JOURNAL OF RADIOLOGY, 2024, 98 (1166): : 305 - 311