Analysis of urinary methylated nucleosides of patients with coronary artery disease by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry

被引:13
|
作者
Li, Yanru [1 ]
Yu, Haiyi [2 ,3 ,4 ]
Zhao, Wei [2 ,3 ,4 ]
Xu, Xinye [2 ,3 ,4 ]
Zhou, Jiang [1 ]
Xu, Ming [2 ,3 ,4 ]
Gao, Wei [2 ,3 ,4 ]
Yuan, Gu [1 ]
机构
[1] Peking Univ, Coll Chem & Mol Engn, Beijing Natl Lab Mol Sci, Beijing 100871, Peoples R China
[2] Peking Univ Third Hosp, Key Lab Mol Cardiovasc Sci, Minist Educ, Dept Cardiol, Beijing, Peoples R China
[3] Peking Univ Third Hosp, Key Lab Mol Cardiovasc Sci, Minist Educ, Inst Vasc Med, Beijing, Peoples R China
[4] Minist Hlth, Key Lab Mol Cardiovasc Mol Biol & Regulatory Pept, Beijing, Peoples R China
关键词
POTENTIAL TUMOR-MARKERS; CANCER-PATIENTS; BREAST-CANCER; HEART-FAILURE; CLINICAL-DIAGNOSIS; COLORECTAL-CANCER; MS ANALYSIS; IDENTIFICATION; ANGIOTENSIN; PHENOTYPE;
D O I
10.1002/rcm.6986
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE: In recent years, methylated nucleosides have been considered to be potential biomarkers to human diseases. The early diagnosis of coronary artery disease (CAD) is an unsolved problem in clinical cardiology. The aim of our study is to evaluate whether urinary methylated nucleosides can serve as useful biomarkers for CAD. METHODS: A solid-phase extraction (SPE) column was used for extraction and purification of methylated nucleosides in urine, and high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) was employed for specific, sensitive and rapid determination of the urinary methylated nucleosides from patients with cardiac events. RESULTS: We have analyzed six methylated nucleosides (N-3-methylcytidine, N-1-methyladenosine, N-6-methyladenosine, N-2-methylguanosine, N-1-methylguanosine and N-2, N-2-dimethylguanosine) in urine from 51 patients with CAD and 25 non-CADcontrols byHPLC/ESI-MS/MS using selective reactionmonitoring (SRM). Our results have shown that there were significant differences in the N-6-methyladenosine levels from the patients and the non-CAD controls in the urine analyzed. CONCLUSIONS: The results have indicated that HPLC/ESI-MS/MS is a highly specific and sensitive tool to measure urinary methylated nucleosides for analysis of CAD. Our result has revealed that the evaluation of urinary methylated nucleosides might be helpful in the analysis of CAD by liquid chromatography/mass spectrometry. Therefore, this N-6-methyladenosine is worthy of further studies in the near future. Copyright (C) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:2054 / 2058
页数:5
相关论文
共 50 条
  • [1] Analysis of urinary nucleosides as potential tumor markers in human colorectal cancer by high performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Hsu, Wei-Yi
    Chen, William Tzu-Liang
    Lin, Wei-De
    Tsai, Fuu-Jen
    Tsai, Yuhsin
    Lin, Ching-Tsung
    Lo, Wan-Yu
    Jeng, Long-Bin
    Lai, Chien-Chen
    CLINICA CHIMICA ACTA, 2009, 402 (1-2) : 31 - 37
  • [2] Analysis of urinary nucleosides as potential tumor markers in human breast cancer by high performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Hsu, Wei-Yi
    Lin, Wei-De
    Tsai, Yuhsin
    Lin, Chiung-Tsung
    Wang, Hwei-Chung
    Jeng, Long-Bin
    Lee, Ching-Chih
    Lin, Yu-Chiang
    Lai, Chien-Chen
    Tsai, Fuu-Jen
    CLINICA CHIMICA ACTA, 2011, 412 (19-20) : 1861 - 1866
  • [3] Determination of Tripamide in human urine by high-performance liquid chromatography and high-performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Kim, Y
    Hwang, J
    Kim, M
    Lee, W
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (04) : 301 - 306
  • [4] Analysis of iridoid glucosides in Hedyotis diffusa by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Li, Cunman
    Xue, Xingya
    Zhou, Dayong
    Zhang, Feifang
    Xu, Qing
    Ren, Lingling
    Liang, Xinmiao
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (01) : 205 - 211
  • [5] Porphomethene inhibitor of uroporphyrinogen decarboxylase: analysis by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Danton, Malcolm
    Lim, Chang Kee
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (07) : 661 - 663
  • [6] Determination of urinary oligosaccharides by high-performance liquid chromatography/electrospray ionization-tandem mass spectrometry: Application to Hunter syndrome
    Nielsen, Timothy C.
    Rozek, Tomas
    Hopwood, John J.
    Fuller, Maria
    ANALYTICAL BIOCHEMISTRY, 2010, 402 (02) : 113 - 120
  • [7] ANALYSIS OF URINARY PORPHYRINS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION MASS SPECTROMETRY
    Li, Jinhua
    Cai, Zongwei
    Xu, Shoufang
    Liao, Chunyang
    Song, Xingliang
    Chen, Lingxin
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2011, 34 (15) : 1578 - 1593
  • [8] Determination of nalmefene by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry
    Fang, WB
    Andrenyak, DM
    Moody, DE
    Nuwayser, ES
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2005, 29 (03) : 169 - 174
  • [9] Identification of Ceftiofur Oxidation Products by High-Performance Liquid Chromatography/Electrospray Ionization/Tandem Mass Spectrometry
    Lim, Young-Hee
    Park, Deok-Hie
    Youn, Yeu Young
    Kim, Kyung Hoon
    Cho, Hye-Sung
    MASS SPECTROMETRY LETTERS, 2011, 2 (01) : 16 - 19
  • [10] Molecular species of sphingomyelin:: Determination by high-performance liquid chromatography mass spectrometry with electrospray and high-performance liquid chromatography tandem mass spectrometry with atmospheric pressure chemical ionization
    Karlsson, AÅ
    Michélsen, P
    Odham, G
    JOURNAL OF MASS SPECTROMETRY, 1998, 33 (12): : 1192 - 1198