INNOVATIVE METHODS USING OF 2-D THERMOLUMINESCENT DOSIMETRY

被引:0
|
作者
Kopec, Renata [1 ]
机构
[1] Inst Nucl Phys Polish Acad Sci IFJ PAN, Krakow, Poland
关键词
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Nowadays the main thermoluminescence dosimetry systems for measurements of individual and environmental doses are based on thermoluminescent (TLD) detectors. In 2005 at the IFJ PAN a new system of 2-D measurements with specially prepared planar thermoluminescent dosemeter was built. The system contains TL detector (special developed planar TL foil with different size or normal pellets - 0.9 thickness and 2.4 diameter) and a special TL reader where CCD camera is measuring TL signal. The result from that system is 2-D image of TL lighting. The new system has found a few practical applications. Historically first use of TL foils was for measurements of dose distribution around anode like X-ray tube. Next use was for check in doses using radiotherapy procedures and finally to distinguish between static and dynamic exposure in individual dosimetry. During last two years TL foils were tested in interventional radiology procedures. In this work the results of different studies on the two-dimensional technique, both using TL pellets (to distinguish static or dynamic exposure) as well as the TL planar foils will be presented.
引用
收藏
页码:180 / 180
页数:1
相关论文
共 50 条
  • [1] Energy dependence of the sensitivity of a europium doped barium sulphate thermoluminescent sheet for 2-D radiation dosimetry
    Iwata, K
    Yue, N
    Nath, R
    MEDICAL PHYSICS, 2004, 31 (06) : 1838 - 1838
  • [2] PERSONNEL DOSIMETRY USING THERMOLUMINESCENT DOSIMETERS
    CUSIMANO, JP
    CIPPERLEY, FV
    HEALTH PHYSICS, 1968, 14 (04): : 339 - +
  • [3] RADIOIMMUNOTHERAPY DOSIMETRY USING THERMOLUMINESCENT DOSIMETERS
    SULLIVAN, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (06): : 734 - 735
  • [4] REACTOR FLUX MEASUREMENTS USING THERMOLUMINESCENT DOSIMETRY
    MCKLVEEN, JW
    SCHWENK, M
    NUCLEAR TECHNOLOGY, 1976, 31 (02) : 257 - 263
  • [5] New 2-D dosimetric technique for radiotherapy based on planar thermoluminescent detectors
    Olko, P.
    Marczewska, B.
    Czopyk, L.
    Czermak, M. A.
    Klosowski, M.
    Waligorski, M. P. R.
    RADIATION PROTECTION DOSIMETRY, 2006, 118 (02) : 213 - 218
  • [6] Identifying Singular 2-D Systems Using 1-D Methods
    Shafiee, Masoud
    Azarakhsh, Kamyar
    2024 32ND INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, ICEE 2024, 2024, : 1171 - 1177
  • [7] ULTRAVIOLET DOSIMETRY USING THERMOLUMINESCENT PHOSPHORUS RATE DEPENDENCE
    NAGPAL, JS
    RADIATION EFFECTS LETTERS, 1979, 43 (4-5): : 173 - 176
  • [8] THERMOLUMINESCENT DOSIMETRY USING LITHIUM FLUORIDE IN AQUEOUS SUSPENSION
    SPURNY, Z
    NOVOTNY, J
    HEDVICAKOVA, L
    PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (02): : 295 - +
  • [9] A Simple Method for 2-D In Vivo Dosimetry by Portal Imaging
    Peca, Stefano
    Brown, Derek Wilson
    Smith, Wendy Lani
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2017, 16 (06) : 944 - 955
  • [10] NEUTRON DOSIMETRY WITH THERMOLUMINESCENT NATURAL CAF2
    WATANABE, S
    MUCCILLO, R
    HEALTH PHYSICS, 1970, 19 (02): : 330 - +