Gadolinium Retention in the Brain: An MRI Relaxometry Study of Linear and Macrocyclic Gadolinium-Based Contrast Agents in Multiple Sclerosis

被引:27
|
作者
Forslin, Y. [1 ,2 ]
Martola, J. [1 ,2 ]
Bergendal, A. [1 ]
Fredrikson, S. [1 ,3 ]
Wiberg, M. K. [1 ,2 ,4 ]
Granberg, T. [1 ,2 ]
机构
[1] Karolinska Inst, Dept Clin Neurosci, Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Radiol, C1-46, S-14186 Stockholm, Sweden
[3] Karolinska Univ Hosp, Dept Neurol, Stockholm, Sweden
[4] Linkoping Univ, Dept Med & Hlth Sci, Div Radiol Sci, Linkoping, Sweden
关键词
DENTATE NUCLEUS; SIGNAL-INTENSITY; MAGNETIC-RESONANCE; GLOBUS-PALLIDUS; HEALTHY RATS; ADMINISTRATIONS; GADOBUTROL; IMAGES; ASSOCIATION; GADODIAMIDE;
D O I
10.3174/ajnr.A6112
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Brain gadolinium retention is consistently reported for linear gadolinium-based contrast agents, while the results for macrocyclics are contradictory and potential clinical manifestations remain controversial. Furthermore, most previous studies are based on conventional T1-weighted MR imaging. We therefore aimed to quantitatively investigate longitudinal and transversal relaxation in the brain in relation to previous gadolinium-based contrast agent administration and explore associations with disability in multiple sclerosis. MATERIALS AND METHODS: Eighty-five patients with MS and 21 healthy controls underwent longitudinal and transverse relaxation rate (R-1 and R-2) relaxometry. Patients were divided into linear, mixed, and macrocyclic groups based on previous gadolinium-based contrast agent administration. Neuropsychological testing was performed in 53 patients. The dentate nucleus, globus pallidus, caudate nucleus, and thalamus were manually segmented. Repeatability measures were also performed. RESULTS: The relaxometry was robust (2.0% scan-rescan difference) and detected higher R-1 (dentate nucleus, globus pallidus, caudate nucleus, thalamus) and R-2 (globus pallidus, caudate nucleus) in patients receiving linear gadolinium-based contrast agents compared with controls. The number of linear gadolinium-based contrast agent administrations was associated with higher R-1 and R-2 in all regions (except R-2 in the thalamus). No similar differences and associations were found for the macrocyclic group. Higher relaxation was associated with lower information-processing speed (dentate nucleus, thalamus) and verbal fluency (caudate nucleus, thalamus). No associations were found with physical disability or fatigue. CONCLUSIONS: Previous linear, but not macrocyclic, gadolinium-based contrast agent administration is associated with higher relaxation rates in a dose-dependent manner. Higher relaxation in some regions is associated with cognitive impairment but not physical disability or fatigue in MS. The findings should be interpreted with care but encourage studies into gadolinium retention and cognition.
引用
收藏
页码:1265 / 1273
页数:9
相关论文
共 50 条
  • [1] Linear Gadolinium-Based Contrast Agents Are Associated With Brain Gadolinium Retention in Healthy Rats
    Robert, Philippe
    Violas, Xavier
    Grand, Sylvie
    Lehericy, Stephane
    Idee, Jean-Marc
    Ballet, Sebastien
    Corot, Claire
    INVESTIGATIVE RADIOLOGY, 2016, 51 (02) : 73 - 82
  • [2] Gadolinium Deposition in the Brain in a Large Animal Model Comparison of Linear and Macrocyclic Gadolinium-Based Contrast Agents
    Radbruch, Alexander
    Richter, Henning
    Fingerhut, Stefanie
    Martin, Louise Francoise
    Xia, Anna
    Henze, Niklas
    Paulus, Werner
    Sperling, Michael
    Karst, Uwe
    Jeibinann, Astrid
    INVESTIGATIVE RADIOLOGY, 2019, 54 (09) : 531 - 536
  • [3] Gadolinium Mapping in the Pig Brain by LA-ICP-MS After Multiple Administrations of Linear or Macrocyclic Gadolinium-Based Contrast Agents
    Boyken, J.
    Jost, G.
    Frenzel, T.
    Pietsch, H.
    INVESTIGATIVE RADIOLOGY, 2019, 54 (12) : 794 - 794
  • [4] Histology and Gadolinium Distribution in the Rodent Brain After the Administration of Cumulative High Doses of Linear and Macrocyclic Gadolinium-Based Contrast Agents
    Lohrke, Jessica
    Frisk, Anna-Lena
    Frenzel, Thomas
    Schoeckel, Laura
    Rosenbruch, Martin
    Jost, Gregor
    Lenhard, Diana Constanze
    Sieber, Martin A.
    Nischwitz, Volker
    Kueppers, Astrid
    Pietsch, Hubertus
    INVESTIGATIVE RADIOLOGY, 2017, 52 (06) : 324 - 333
  • [5] Post-contrast MRI in multiple sclerosis: Towards a judicious use of gadolinium-based contrast agents
    Gentili, Lucia
    Capuano, Rocco
    Gaetani, Lorenzo
    Fiacca, Andrea
    Bisecco, Alvino
    D'Ambrosio, Alessandro
    Mancini, Andrea
    Guercini, Giorgio
    Tedeschi, Gioacchino
    Parnetti, Lucilla
    Gallo, Antonio
    Di Filippo, Massimiliano
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2022, 442
  • [6] Brain gadolinium deposition after administration of gadolinium-based contrast agents
    Tomonori Kanda
    Hiroshi Oba
    Keiko Toyoda
    Kazuhiro Kitajima
    Shigeru Furui
    Japanese Journal of Radiology, 2016, 34 : 3 - 9
  • [7] Brain gadolinium deposition after administration of gadolinium-based contrast agents
    Kanda, Tomonori
    Oba, Hiroshi
    Toyoda, Keiko
    Kitajima, Kazuhiro
    Furui, Shigeru
    JAPANESE JOURNAL OF RADIOLOGY, 2016, 34 (01) : 3 - 9
  • [8] Retention of Gadolinium-Based Contrast Agents in Multiple Sclerosis: Retrospective Analysis of an 18-Year Longitudinal Study
    Forslin, Y.
    Shams, S.
    Hashim, F.
    Aspelin, P.
    Bergendal, G.
    Martola, J.
    Fredrikson, S.
    Kristoffersen-Wiberg, M.
    Granberg, T.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (07) : 1311 - 1316
  • [9] Copper responsive gadolinium-based MRI contrast agents
    Paranawithana, Namini
    Martins, Andre
    Meloni, Gabriele
    Chirayil, Sara
    Zhao, Piyu
    Sherry, A. Dean
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [10] In vivo dentate nucleus MRI relaxometry correlates with previous administration of Gadolinium-based contrast agents
    Tedeschi, Enrico
    Palma, Giuseppe
    Canna, Antonietta
    Cocozza, Sirio
    Russo, Carmela
    Borrelli, Pasquale
    Lanzillo, Roberta
    Angelini, Valentina
    Postiglione, Emanuela
    Morra, Vincenzo Brescia
    Salvatore, Marco
    Brunetti, Arturo
    Quarantelli, Mario
    EUROPEAN RADIOLOGY, 2016, 26 (12) : 4577 - 4584