Long-term stability of a TLD-based individual monitoring system

被引:6
|
作者
Alves, J. G. [1 ]
Abrantes, J. N. [1 ]
Margo, O. [1 ]
Rangel, S. [1 ]
Santos, L. [1 ]
机构
[1] Inst Tecnol & Nucl, Dept Proteccao Radiol & Seguranca Nucl, P-2686953 Sacavem, Portugal
关键词
D O I
10.1093/rpd/nci520
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The thermoluminescence dosemeter (TLD) system at the Individual Monitoring Service (IMS) of the Nuclear Technology Institute (ITN) at the Radiological Protection and Nuclear Safety Department (DPRSN) comprises two 6600 Harshaw readers and the Harshaw 8814 TL card and the holder containing two LiF:Mg,Ti (TLD-100) dosemeters for the evaluation of H-p(10) and H-p(0.07). The readers are calibrated on a monthly basis and as part of the quality assurance programme implemented at the IMS a set of dosemeters is issued monthly to the DPRSN's Standard Dosimetry Laboratory for linearity measurements. The results obtained since November 2001 are presented. Fading and sensitivity change experiments are carried out every month covering 8 week periods so that enough time is given to simulate issuing, integrating and receiving times and respective delays. A set of 96 dosemeters organised in eight subsets of 12 are used. In each subset, four dosemeters are irradiated and stored at room temperature (RT), four are not irradiated at all and the last four are irradiated after storage. The 12 dosemeters of each subset are readout at the same time, one per week, covering the 8 week period. The results from the sets irradiated and stored at different periods allowed for the evaluation of fading and sensitivity changes experienced over the whole monitoring period and respective preparation time and readout delays. Time evolution charts of the reader calibration factors, of the linearity parameters and of the evolution of the integrated area in the region of dosimetric interest with storage at RT were obtained. This paper aims to quantify the long-term stability of the TLD system in use at the IMS.
引用
收藏
页码:289 / 292
页数:4
相关论文
共 50 条
  • [1] A TLD-based personal dosemeter system for aircrew monitoring
    Hajek, M
    Berger, T
    Vana, N
    [J]. RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 337 - 341
  • [2] A TLD-based ten channel system for the spectrometry of bremsstrahlung generated by laser-matter interaction
    Horst, Felix
    Fehrenbacher, Georg
    Radon, Torsten
    Kozlova, Ekaterina
    Rosmej, Olga
    Czarnecki, Damian
    Schrenk, Oliver
    Breckow, Joachim
    Zink, Klemens
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 782 : 69 - 76
  • [3] Quality assurance for a TLD based individual monitoring service
    Julius, HW
    van Dijk, JWE
    [J]. RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 1 - 6
  • [4] Stability analysis of abutment slopes based on long-term monitoring and numerical simulation
    Yu, Yang
    Wang, Enzhi
    Zhong, Jianwen
    Liu, Xiaoli
    Li, Penghui
    Shi, Mei
    Zhang, Zhiguo
    [J]. ENGINEERING GEOLOGY, 2014, 183 : 159 - 169
  • [5] Long-Term Stability Monitoring of Printed Proteins on Paper-Based Membranes
    Koh, Byumseok
    Kim, Kwang Rok
    [J]. ACS OMEGA, 2019, 4 (12): : 15134 - 15138
  • [6] LONG-TERM STABILITY MONITORING IN THE PRAGUE CASTLE AREA
    Prochazka, Jaromir
    Zalesky, Jan
    Jirikovsky, Tomas
    Salak, Jan
    [J]. ACTA GEODYNAMICA ET GEOMATERIALIA, 2010, 7 (04): : 411 - +
  • [7] Long-term stability of individual differences in electrodermal activity (EDA)
    Kronholm, E
    Hyyppa, MT
    [J]. INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 1997, 25 (01) : 37 - 38
  • [8] A PC-based system for long-term monitoring of animal activity
    Wu, BM
    Chan, FHY
    Lam, FK
    Lam, MC
    Poon, PWF
    Poon, AMS
    [J]. PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 1910 - 1913
  • [9] LONG-TERM STABILITY OF INDIVIDUAL DIFFERENCES IN EXPLORATORY BEHAVIOUR OF DOGS
    MARTINEK, Z
    LAT, J
    [J]. PHYSIOLOGIA BOHEMOSLOVACA, 1968, 17 (05): : 475 - &
  • [10] Study on quality control parameters of a TLD system for individual monitoring
    Alves, JG
    Montezuma, R
    Margo, O
    Santos, L
    [J]. RADIATION PROTECTION DOSIMETRY, 2004, 111 (01) : 21 - 25