Stearic Acid Coating Material Loading Effect to Quartz Crystal Microbalance Sensor

被引:0
|
作者
Sakti, Setyawan Purnomo [1 ,2 ]
Masruroha [2 ]
Kamasi, Daniel Dwipaskawijaya [1 ]
Khusnah, Nike Fitayatul [1 ]
机构
[1] Brawijaya Univ, Dept Phys, Jl Vet, Malang 65145, Indonesia
[2] Brawijaya Univ, Colaborat Res Ctr Adv Syst & Mat Technol, Jl Vet, Malang 65145, Indonesia
关键词
QCM sensor; loading effect; stearic acid; thick coating; impedance spectrum; RESONATOR; FILMS;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The coating layer was a crucial aspect for the selectivity of the Quartz Crystal Microbalance sensor. The coating layer can contribute to the loading effect of the sensor. The loading effect of the polystyrene film to the sensor is negligible, whilst the stearic acid coating layer contributes high damping. The calculated film thickness of the stearic acid using an assumption of the rigid was different from the measured film thickness using profilometer. The thickness difference between the measured film and Butterworth van Dyke model calculation indicated that the stearic acid film could be considered as a nonrigid film. (c) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [1] Ultra thick polystyrene coating on quartz crystal microbalance sensor
    Sakti, Setyawan P.
    Masruroh
    Istiroyah
    Kamasi, Daniel D.
    Zafirah, Tyas N.
    MATERIALS TODAY-PROCEEDINGS, 2021, 44 : 3217 - 3220
  • [2] A quartz crystal microbalance sensor for the detection of formic acid vapors
    C. García-Verdugo-Caso
    J. L. Hidalgo-Hidalgo-de-Cisneros
    I. Naranjo-Rodríguez
    D. Bellido-Milla
    Fresenius' Journal of Analytical Chemistry, 2001, 370 : 393 - 398
  • [3] A quartz crystal microbalance sensor for the detection of formic acid vapors
    García-Verdugo-Caso, C
    Hidalgo-Hidalgo-de-Cisneros, JL
    Naranjo-Rodríguez, I
    Bellido-Milla, D
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (04): : 393 - 398
  • [4] A Simple Quartz Crystal Microbalance Nucleic Acid Sensor for Detection of Telomerase
    Oeztuerk, K.
    Durusoy, M.
    Piskin, E.
    JOURNAL OF BIOACTIVE AND COMPATIBLE POLYMERS, 2008, 23 (06) : 579 - 593
  • [5] Chitosan Coating on Quartz Crystal Microbalance Gas Sensor for Isopropyl Alcohol and Acetone Detection
    Hekiem, Nurul Liyana Lukman
    Ralib, Aliza Aini Md
    Akmal, M. H. Maziati
    Ahmad, Farah B.
    Ab Rahim, Rosminazuin
    Za'bah, Nor Farahidah
    Sugandi, Gandi
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2022, 14 (03): : 241 - 249
  • [6] QUARTZ-CRYSTAL MICROBALANCE SENSOR IN LIQUIDS
    AUGE, J
    HAUPTMANN, P
    EICHELBAUM, F
    ROSLER, S
    SENSORS AND ACTUATORS B-CHEMICAL, 1994, 19 (1-3) : 518 - 522
  • [7] Determination of microorganisms with a quartz crystal microbalance sensor
    Bao, LL
    Deng, L
    Nie, LH
    Yao, SZ
    Wei, WZ
    ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) : 97 - 101
  • [8] Is quartz crystal microbalance really a mass sensor?
    Mecea, VM
    SENSORS AND ACTUATORS A-PHYSICAL, 2006, 128 (02) : 270 - 277
  • [9] Quartz crystal microbalance based histidine sensor
    Sonmezler, Merve
    Ozgur, Erdogan
    Yavuz, Handan
    Denizli, Adil
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2019, 47 (01) : 221 - 227
  • [10] Method for measuring the losses and loading of a quartz crystal microbalance
    Kankare, J
    Loilkas, K
    Salomäki, M
    ANALYTICAL CHEMISTRY, 2006, 78 (06) : 1875 - 1882