Comparison of biomechanical effects of small-incision lenticule extraction and laser in situ keratomileusis: Finite-element analysis

被引:149
|
作者
Roy, Abhijit Sinha [1 ]
Dupps, William J., Jr. [1 ,2 ,3 ]
Roberts, Cynthia J. [4 ,5 ]
机构
[1] Case Western Reserve Univ, Cole Eye Inst, Cleveland Clin Fdn, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Lerner Res Inst, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[4] Ohio State Univ, Dept Ophthalmol, Columbus, OH 43210 USA
[5] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
来源
关键词
COHESIVE TENSILE-STRENGTH; FEMTOSECOND LASER; REFRACTIVE SURGERY; FLAP THICKNESS; LASIK; MICROKERATOME; MYOPIA; ECTASIA; RELEX;
D O I
10.1016/j.jcrs.2013.08.065
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To theoretically compare the corneal stress distribution of laser in situ keratomileusis (LASIK) with the stress distribution of small-incision lenticule extraction. SETTING: Cleveland Clinic Cole Institute, Cleveland, and The Ohio State University, Columbus, Ohio, USA. DESIGN: Computational modeling study. METHODS: A finite-element anisotropic collagen fiber-dependent model of myopic surgery using patient-specific corneal geometry was constructed for LASIK, small-incision lenticule extraction, and a geometry analog model with unaltered material properties from preoperative but with postoperative geometry including thickness. Surgical parameters, magnitude of myopic correction, LASIK flap thickness, and lenticule depth in small-incision lenticule extraction were varied. Two sets of models, 1 with uniform and 1 with depth-dependent material properties, were constructed. RESULTS: Stress distribution between small-incision lenticule extraction simulations and the geometry analog model were similar. In contrast, LASIK consistently reduced stress in the flap and increased stress in the residual stromal bed (RSB) compared with the geometry analog model. An increase in flap thickness or lenticule depth resulted in a greater increase in RSB stress in the LASIK model than in the small-incision lenticule extraction model. CONCLUSIONS: Small-incision lenticule extraction may present less biomechanical risk to the residual bed of susceptible corneas than comparable corrections involving LASIK flaps. Deeper corrections in the stroma may be possible in small-incision lenticule extraction without added risk for ectasia. (C) 2014 ASCRS and ESCRS
引用
收藏
页码:971 / 980
页数:10
相关论文
共 50 条
  • [1] Effects of Laser In Situ Keratomileusis and Small-Incision Lenticule Extraction on Corneal Biomechanical Behavior: A Finite Element Analysis
    Wang, Chenyan
    Li, Xiaona
    Guo, Yuan
    He, Rui
    Guo, Hongmei
    Chen, Weiyi
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [2] Comparison of Biomechanical Effects of Small Incision Lenticule Extraction (SMILE) and Laser in situ Keratomileusis (LASIK): A Finite Element Analysis Study
    Roy, Abhijit Sinha
    Dupps, William
    Roberts, Cynthia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [3] Corneal biomechanical effects: Small-incision lenticule extraction versus femtosecond laser-assisted laser in situ keratomileusis
    Wu, Di
    Wang, Yan
    Zhang, Lin
    Wei, Shengsheng
    Tang, Xin
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (06): : 954 - 962
  • [4] Comparison of Perioperative Contrast Sensitivity between Laser in situ Keratomileusis and Small-incision Lenticule Extraction
    Park, Se Young
    Kwag, Joo Young
    Hyun, Joo
    Pak, Kyu Hong
    Chung, Sung Kun
    Choi, Jin Seok
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (08): : 890 - 896
  • [5] Corneal sensitivity after small-incision lenticule extraction and laser in situ keratomileusis
    Reinstein, Dan Z.
    Archer, Timothy J.
    Gobbe, Marine
    Bartoli, Elena
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (08): : 1580 - 1587
  • [6] Comparison of biomechanical effects of small incision lenticule extraction and laser-assisted subepithelial keratomileusis
    Chen, Minjie
    Yu, Manrong
    Dai, Jinhui
    ACTA OPHTHALMOLOGICA, 2016, 94 (07) : E586 - E591
  • [7] Comparison of biomechanical effects of small incision lenticule extraction and laser-assisted subepithelial keratomileusis
    Chen, Minjie
    Dai, Jinhui
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [8] Corneal biomechanical changes in eyes with small incision lenticule extraction and laser assisted in situ keratomileusis
    Osman, Ihab Mohamed
    Helaly, Hany Ahmed
    Abdalla, Moones
    Abou Shousha, Mohsen
    BMC OPHTHALMOLOGY, 2016, 16
  • [9] Corneal biomechanical changes in eyes with small incision lenticule extraction and laser assisted in situ keratomileusis
    Ihab Mohamed Osman
    Hany Ahmed Helaly
    Moones Abdalla
    Mohsen Abou Shousha
    BMC Ophthalmology, 16
  • [10] Comparing Patient-Reported Outcomes of Laser In Situ Keratomileusis and Small-Incision Lenticule Extraction: A Review
    Chiam, Nathalie P. Y.
    Mehta, Jodhbir S.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2019, 8 (05): : 377 - 384