A γ calorimeter for the monitoring of the ELI-NP beam

被引:3
|
作者
Veltri, M. [2 ,8 ]
Adriani, O. [1 ,2 ]
Albergo, S. [3 ,4 ]
Andreotti, M. [6 ]
Borgheresi, R. [1 ,2 ]
Cappello, G. [4 ]
Cardarelli, P. [5 ,6 ]
Ciaranfi, R. [2 ]
Consoli, E. [5 ,6 ]
Di Domenico, G. [5 ,6 ]
Evangelisti, F. [6 ]
Gambaccini, M. [5 ,6 ]
Graziani, G. [2 ]
Lenzi, M. [2 ]
Maletta, F. [2 ]
Marziani, M. [5 ,6 ]
Passaleva, G. [2 ]
Paterno, G. [6 ]
Serban, A. [2 ]
Squerzanti, S. [6 ]
Starodubtsev, O. [2 ]
Tricomi, A. [3 ,4 ]
Variola, A. [7 ]
机构
[1] Univ Firenze, Dipartimento Fis & Astron, Florence, Italy
[2] Ist Nazl Fis Nucl, Sez Firenze, Florence, Italy
[3] Univ Catania, Dipartimento Fis & Astron, Catania, Italy
[4] Ist Nazl Fis Nucl, Sez Catania, Catania, Italy
[5] Univ Ferrara, Dipartimento Fis & Sci Terra, Ferrara, Italy
[6] Ist Nazl Fis Nucl, Sez Ferrara, Ferrara, Italy
[7] Ist Nazl Fis Nucl, Lab Nazl Frascati, Frascati, Italy
[8] Univ Urbino, Dipartimento Sci Pure & Applicate, Urbino, Italy
关键词
Calorimeters; Beam characteristics; FACILITY;
D O I
10.1016/j.nima.2018.10.001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The ELI-NP facility will provide a monochromatic, high brilliance y beam with tunable energy up to 19.5 MeV. The time structure of the beam consists of 32 pulses of 10(5) photons separated by 16 ns and delivered at repetition rate of 100 Hz. In order to match such unprecedented beam specifications and to measure its energy spectrum, intensity and space profile, a characterization system has been developed. This paper will focus on the working principle, the expected performances and the results of tests carried out on a low-Z sampling calorimeter, made of silicon detectors and polyethylene absorbers, which will measure the average beam energy and its intensity. The results of tests performed with an infrared pulsed laser have shown the capability of the detector to cope with the time structure of ELI-NP beam. Further tests carried out at the LABEC facility in Firenze have shown the excellent linearity of the silicon detectors in the energy range relevant to ELI-NP beam.
引用
收藏
页码:82 / 85
页数:4
相关论文
共 50 条
  • [1] Gamma Beam Characterization System for ELI-NP: The Gamma Absorption Calorimeter
    Borgheresi, R.
    Adriani, O.
    Albergo, S.
    Andreotti, M.
    Berto, D.
    Cappello, G.
    Cardarelli, P.
    Ciaranfi, R.
    Consoli, E.
    Di Domenico, G.
    Evangelisti, F.
    Gambaccini, M.
    Graziani, G.
    Lenzi, M.
    Maletta, F.
    Marziani, M.
    Palumbo, L.
    Passaleva, G.
    Pellegriti, M. G.
    Serban, A.
    Starodubtsev, O.
    Statera, M.
    Tricomi, A.
    Variola, A.
    Veltri, M.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [2] Gamma Beam System at ELI-NP
    Ur, Calin A.
    EXOTIC NUCLEI AND NUCLEAR/PARTICLE ASTROPHYSICS (V). FROM NUCLEI TO STARS, 2015, 1645 : 237 - 245
  • [3] LASER BEAM DELIVERY AT ELI-NP
    Ursescu, D.
    Cheriaux, G.
    Audebert, P.
    Kalashnikov, M.
    Toncian, T.
    Cerchez, M.
    Kaluza, M.
    Paulus, G.
    Priebe, G.
    Dabu, R.
    Cernaianu, M. O.
    Dinescu, M.
    Asavei, T.
    Dancus, I.
    Neagu, L.
    Boianu, A.
    Hooker, C.
    Barty, C.
    Haefner, C.
    ROMANIAN REPORTS IN PHYSICS, 2016, 68 : S11 - S36
  • [4] A new-concept gamma calorimeter at ELI-NP
    Lenzi, M.
    Adriani, O.
    Albergo, S.
    Andreotti, M.
    Berto, D.
    Borgheresi, R.
    Cappello, G.
    Cardarelli, P.
    Ciaranfi, R.
    Consoli, E.
    Di Domenico, G.
    Evangelisti, F.
    Gambaccini, M.
    Graziani, G.
    Marziani, M.
    Palumbo, L.
    Passaleva, G.
    Pellegriti, M. G.
    Serban, A.
    Starodubtsev, O.
    Statera, M.
    Tricomi, A.
    Variola, A.
    Veltri, M.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [5] POSITRON PRODUCTION BY GAMMA BEAM AT ELI-NP
    Djourelov, N.
    Hugenschmidt, C.
    Balascuta, S.
    Leca, V.
    Oprisa, A.
    Piochacz, C.
    Teodorescu, C.
    Ur, C. A.
    ROMANIAN REPORTS IN PHYSICS, 2016, 68 : S735 - S797
  • [6] Gamma beam industrial applications at ELI-NP
    Suliman, Gabriel
    Iancu, Violeta
    Ur, Calin A.
    Iovea, Mihai
    Daito, Izuru
    Ohgaki, Hideaki
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON APPLICATIONS OF NUCLEAR TECHNIQUES (CRETE15), 2016, 44
  • [7] Collimation and characterization of ELI-NP gamma beam
    Cappello, G.
    Adriani, O.
    Albergo, S.
    Andreotti, M.
    Berto, D.
    Borgheresi, R.
    Cardarelli, P.
    Ciaranfi, R.
    Consoli, E.
    Di Domenico, G.
    Evangelisti, F.
    Gambaccini, M.
    Graziani, G.
    Lenzi, M.
    Marziani, M.
    Palumbo, L.
    Passaleva, G.
    Paterno, G.
    Pellegriti, M. G.
    Serban, A.
    Starodubtsev, O.
    Statera, M.
    Tricomi, A.
    Variola, A.
    Veltri, M.
    PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON APPLICATIONS OF NUCLEAR TECHNIQUES (CRETE17), 2018, 48
  • [8] MONITORING AND CONTROL SYSTEMS FOR EXPERIMENTS AT ELI-NP
    Cernaianu, M. O.
    De Boisdeffre, B.
    Ursescu, D.
    Negoita, F.
    Ur, C. A.
    Tesileanu, O.
    Balabanski, D.
    Ivanoaica, T.
    Ciubancan, M.
    Toma, M.
    Dancus, I.
    Gales, S.
    ROMANIAN REPORTS IN PHYSICS, 2016, 68 : S349 - S443
  • [9] Investigation of the d(γ,n)p reaction for gamma beam monitoring at ELI-NP
    Matei, C.
    Mueller, J. M.
    Sikora, M. H.
    Suliman, G.
    Ur, C. A.
    Weller, H. R.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [10] The ELI-NP IGISOL radioactive ion beam facility
    Constantin, P.
    Balabanski, D. L.
    State, A.
    Rotaru, A.
    Nichita, D.
    Spataru, A.
    Dickel, T.
    Plass, W. R.
    Scheidenberger, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 461 : 130 - 132