Porosity, water sorption and solubility of denture base acrylic resins polymerized conventionally or in microwave

被引:39
|
作者
Silva Figueroa, Rosana Marques [1 ]
Conterno, Bruna [1 ]
Galvao Arrais, Cesar Augusto [1 ]
Campos Sugio, Carolina Yoshi [2 ]
Urban, Vanessa Migliorini [1 ]
Neppelenbroek, Karin Hermana [2 ]
机构
[1] Univ Estadual Ponta Grossa, Dept Odontol, Av Gen Carlos Cavalcanti 4748, BR-84030900 Ponta Grossa, Parana, Brazil
[2] Univ Sao Paulo, Fac Odontol Bauru, Dept Protese & Periodontia, Sao Paulo, Brazil
关键词
Polymethyl methacrylate; Polymerization; Porosity; Solubility; Sorption; BOND STRENGTH; ABSORPTION; MONOMER; BATH;
D O I
10.1590/1678-7757-2017-0383
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The proper selection of polymerization cycle is important to prevent overheating of the monomer that could cause degradation, porosity and, consequently, deleterious effects on the denture base properties. Objective: This study evaluated the porosity, water sorption and solubility of acrylic resins (Vipi Cril-VC and Vipi Wave-VW) after conventional or microwave polymerization cycles. Material and Methods: Specimens (n=10) were made and cured: 1-WB = 65 degrees C during 90 min + boiling during 90 min (VC cycle - control group); 2-M25 = 10 min at 270 W + 5 min at 0 W + 10 min at 360 W (VW cycle); 3-M3 = 3 min at 550 W; and 4-M5 = 5 min at 650 W. Afterward, they were polished and dried in a dessicator until a constant mass was reached. Specimens were then immersed in distilled water at 37 degrees C and weighed regularly until a constant mass was achieved. For porosity, an additional weight was made with the specimen immediately immersed in distilled water. For water sorption and solubility, the specimens were dried again until equilibrium was reached. Data were submitted to 2 way-ANOVA and Tukey HSD (alpha=0.05). Results: Porosity mean values below 1.52% with no significant difference among groups for both materials were observed. Resins showed water sorption and solubility values without a significant difference. However, there was a significant difference among groups for these both properties (P<0.013). The highest sorption (2.43%) and solubility (0.13%) values were obtained for WB and M3, respectively. Conclusions: The conventional acrylic resin could be polymerized in a microwave since both the materials showed similar performance in the evaluated properties. Shorter microwave cycles could be used for both the materials without any detectable increase in volume porosity.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Water sorption and solubility of denture base resins polymerized by beat, microwave energy and visible light.
    Prunkngarmpun, C
    Yotnuengnit, B
    Kanchanawasita, W
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 : A169 - A169
  • [2] A COMPARISON OF DENTURE BASE ACRYLIC RESINS POLYMERIZED BY MICROWAVE IRRADIATION AND BY CONVENTIONAL WATER BATH CURING SYSTEMS
    ALDOORI, D
    HUGGETT, R
    BATES, JF
    BROOKS, SC
    [J]. DENTAL MATERIALS, 1988, 4 (01) : 25 - 32
  • [3] Water Sorption, Solubility, and Translucency of 3D-Printed Denture Base Resins
    Gad, Mohammed M.
    Alshehri, Saleh Z.
    Alhamid, Shahad A.
    Albarrak, Alanoud
    Khan, Soban Q.
    Alshahrani, Faris A.
    Alqarawi, Firas K.
    [J]. DENTISTRY JOURNAL, 2022, 10 (03)
  • [4] Effect of staining and denture cleaning on color stability of differently polymerized denture base acrylic resins
    Ayaz, E. A.
    Ustun, S.
    [J]. NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2020, 23 (03) : 304 - 309
  • [5] Sorption and solubility in water of acrilic resins polymerized by microwave, conventional techinique, pressure and heat.
    Salomao, UE
    Almeida, HC
    Mota, JMLF
    Jansen, WC
    Giovanini, JFBG
    [J]. JOURNAL OF DENTAL RESEARCH, 2003, 82 : 210 - 210
  • [6] Effect of microwave irradiation and water storage on the viscoelastic properties of denture base and reline acrylic resins
    Leao Lombardo, Carlos Eduardo
    Canevarolo, Sebastiao Vicente
    dos Santos Nunes Reis, Jose Mauricio
    Machado, Ana Lucia
    Pavarina, Ana Claudia
    Giampaolo, Eunice Teresinha
    Vergani, Carlos Eduardo
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2012, 5 (01) : 53 - 61
  • [7] Influence of mechanical and chemical polishing in the solubility of acrylic resins polymerized by microwave irradiation and conventional water bath
    Machado, C
    Rizzatti-Barbosa, CM
    Gabriotti, MN
    Joia, FA
    Ribeiro, MC
    Sousa, RLS
    [J]. DENTAL MATERIALS, 2004, 20 (06) : 565 - 569
  • [8] COLORING ACRYLIC DENTURE BASE RESINS
    WINKLER, S
    VERNON, HM
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1978, 40 (01): : 4 - 7
  • [9] Acrylic resins as denture base material
    不详
    [J]. JOURNAL OF THE FRANKLIN INSTITUTE, 1939, 228 : 381 - 382
  • [10] Repair Bond Strength of Conventionally and Digitally Fabricated Denture Base Resins to Auto-Polymerized Acrylic Resin: Surface Treatment Effects In Vitro
    Gad, Mohammed M.
    Albazroun, Zainab
    Aldajani, Fatimah
    Elakel, Ahmed M.
    El Zayat, Mai
    Akhtar, Sultan
    Khan, Soban Q.
    Ali, Saqib
    Rahoma, Ahmed M.
    [J]. MATERIALS, 2022, 15 (24)