Effects of Intra-aortic Balloon Pump Counterpulsation on Left Ventricular Mechanoenergetics in a Porcine Model of Acute Ischemic Heart Failure

被引:15
|
作者
Malliaras, Konstantinos [1 ]
Charitos, Efstratios [1 ]
Diakos, Nikolaos [1 ]
Pozios, Iraklis [1 ]
Papalois, Apostolos [2 ]
Terrovitis, John [1 ]
Nanas, John [1 ]
机构
[1] Univ Athens, Sch Med, Laiko Hosp, Dept Cardiol 3, GR-11527 Athens, Greece
[2] Elpen Pharmaceut, Expt Res Ctr, Athens, Greece
关键词
Intra-aortic balloon pump; Counterpulsation; Mechanical circulatory support; Acute heart failure; Pressure-volume loops; CORONARY PERFUSION-PRESSURE; CARDIOGENIC-SHOCK; ISOVOLUMIC RELAXATION; MYOCARDIAL-INFARCTION; DIASTOLIC FUNCTION; CARDIAC-FUNCTION; LOAD; VOLUME; PERFORMANCE; ASSISTANCE;
D O I
10.1007/s12265-014-9600-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We investigated the effects of intra-aortic balloon pump (IABP) counterpulsation on left ventricular (LV) contractility, relaxation, and energy consumption and probed the underlying physiologic mechanisms in 12 farm pigs, using an ischemia-reperfusion model of acute heart failure. During both ischemia and reperfusion, IABP support unloaded the LV, decreased LV energy consumption (pressure-volume area, stroke work), and concurrently improved LV mechanical performance (ejection fraction, stroke volume, cardiac output). During reperfusion exclusively, IABP also improved LV relaxation (tau) and contractility (Emax, PRSW). The beneficial effects of IABP support on LV relaxation and contractility correlated with IABP-induced augmentation of coronary blood flow. In conclusion, we find that during both ischemia and reperfusion, IABP support optimizes LV energetic performance (decreases energy consumption and concurrently improves mechanical performance) by LV unloading. During reperfusion exclusively, IABP support also improves LV contractility and active relaxation, possibly due to a synergistic effect of unloading and augmentation of coronary blood flow.
引用
收藏
页码:810 / 820
页数:11
相关论文
共 50 条
  • [1] Effects of Intra-aortic Balloon Pump Counterpulsation on Left Ventricular Mechanoenergetics in a Porcine Model of Acute Ischemic Heart Failure
    Konstantinos Malliaras
    Efstratios Charitos
    Nikolaos Diakos
    Iraklis Pozios
    Apostolos Papalois
    John Terrovitis
    John Nanas
    [J]. Journal of Cardiovascular Translational Research, 2014, 7 : 810 - 820
  • [2] EFFECTS OF A NOVEL IMPLANTABLE COUNTERPULSATION ASSIST DEVICE ON LEFT VENTRICULAR MECHANOENERGETICS: COMPARISON WITH THE INTRA-AORTIC BALLOON PUMP IN A PORCINE MODEL OF ACUTE HEART FAILURE
    Kontogiannis, Christos
    Nanas, Yiannis
    Sarchosi, Smaragdi
    Kapelios, Christos
    Marinakis, Sotiris
    Aravantinos, Dionysios
    Tachliabouris, Ioannis
    Charitos, Christos
    Perrea, Despina
    Nanas, John
    Malliaras, Konstantinos
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1386 - 1386
  • [3] HEMODYNAMIC EFFECTS OF INTRA-AORTIC BALLOON COUNTERPULSATION ON LEFT HEART-FAILURE
    MATSUKURA, H
    TAMURA, M
    MATSUYAMA, M
    KOH, S
    KATO, H
    HONMA, J
    MATSUNAMI, O
    TAMURA, K
    SASA, T
    KAWAKAMI, T
    KUROSHIM.S
    SUGIE, S
    [J]. JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1973, 37 (08): : 871 - 871
  • [4] Intra-aortic balloon counterpulsation for acute decompensated heart failure
    Mizuno, Masayuki
    Sato, Naoki
    Kajimoto, Katsuya
    Sakata, Yasushi
    Minami, Yuichiro
    Munakata, Ryo
    Hagiwara, Nobuhisa
    Takano, Teruo
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 176 (03) : 1444 - 1446
  • [5] Ventriculoarterial coupling with intra-aortic balloon pump in acute ischemic heart failure
    Kawaguchi, O
    Pae, WE
    Daily, BB
    Pierce, WS
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 117 (01): : 164 - 171
  • [6] Ischemic Colitis Caused by Intra-Aortic Balloon Pump Counterpulsation
    El-Halawany, H.
    Bajwa, A.
    Shobassy, M.
    Qureini, A.
    Chhabra, R.
    [J]. CASE REPORTS IN GASTROINTESTINAL MEDICINE, 2015, 2015
  • [7] INTRA-AORTIC BALLOON COUNTERPULSATION AND CORONARY REVASCULARIZATION FOR LEFT VENTRICULAR POWER FAILURE
    COHN, LH
    LAMBERTI, J
    LESCH, M
    COLLINS, JJ
    [J]. EUROPEAN SURGICAL RESEARCH, 1974, 6 (03) : 129 - 136
  • [8] Acute Hemodynamic Effects of Intra-aortic Balloon Counterpulsation Pumps in Advanced Heart Failure
    Annamalai, Shiva K.
    Buiten, Lyanne
    Esposito, Michele L.
    Paruchuri, Vikram
    Mullin, Andrew
    Breton, Catalina
    Pedicini, Robert
    O'Kelly, Ryan
    Morine, Kevin
    Wessler, Benjamin
    Patel, Ayan R.
    Kiernan, Michael S.
    Karas, Richard H.
    Kapur, Navin K.
    [J]. JOURNAL OF CARDIAC FAILURE, 2017, 23 (08) : 606 - 614
  • [9] Salutary Effects of a Novel Implantable Counterpulsation Assist Device on Left Ventricular Mechanoenergetics in a Porcine Model of Acute Heart Failure
    Malliaras, Konstantinos
    Nanas, Yannis
    Kontogiannis, Chris
    Aravantinos, Dionysios
    Kapelios, Chris
    Marinakis, Sotirios
    Sarchosi, Smaragda
    Vakrou, Stella
    Perrea, Despina
    Nanas, John
    [J]. CIRCULATION, 2016, 134
  • [10] Intra-Aortic Balloon Pump Support in the Isolated Beating Porcine Heart in Nonischemic and Ischemic Pump Failure
    Schampaert, Stephanie
    van Nunen, Lokien X.
    Pijls, Nico H. J.
    Rutten, Marcel C. M.
    van Tuijl, Sjoerd
    van de Vosse, Frans N.
    van 't Veer, Marcel
    [J]. ARTIFICIAL ORGANS, 2015, 39 (11) : 931 - 938