A real-time, large area, high space resolution particle radiography system

被引:3
|
作者
Lo Presti, D. [1 ,2 ]
Bonanno, D. [1 ]
Longhitano, F. [2 ]
Pugliatti, C. [1 ,2 ]
Aiello, S. [2 ]
Cirrone, G. A. P. [3 ]
Giordano, V. [2 ]
Leonora, E. [2 ]
Randazzo, N. [2 ]
Romano, F. [3 ]
Russo, G. V. [1 ,2 ]
Sipala, V. [4 ,5 ]
Stancampiano, C. [3 ]
Ventura, C. [2 ]
机构
[1] Univ Catania, Dept Phys, Catania, Italy
[2] Ist Nazl Fis Nucl, I-95129 Catania, Italy
[3] Ist Nazl Fis Nucl, LNS, I-95129 Catania, Italy
[4] Univ Sassari, Dept Phys, I-09042 Cagliari, Italy
[5] Ist Nazl Fis Nucl, I-09042 Cagliari, Italy
来源
JOURNAL OF INSTRUMENTATION | 2014年 / 9卷
关键词
Real-time monitoring; Optical detector readout concepts; Dosimetry concepts and apparatus; Instrumentation for hadron therapy; PROJECT;
D O I
10.1088/1748-0221/9/06/C06012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper we describe a new detection system for the high resolution measurement of the residual range of charged particles, designed and developed with the aim of achieving real-time data acquisition and large detection areas. A prototype of the residual range detector, with a sensitive area of about 4 x 4 cm(2), consisting of a stack of sixty ribbons of scintillating fibers (Sci-Fi) has been designed and tested. Each layer is read-out by two wavelength shifter (WLS) fibers and a position sensitive photomultiplier (PSPM). The Bragg peak shape is calculated real-time by the time over a suitable threshold for each channel. The results of the measurements taken using the prototype and a 62 MeV proton beam and a comparison with the GEANT4 simulations of the detector are presented. The main concepts on which the prototype is based have been used to demonstrate the technique patented by the INFN. The next step will be to design and validate the final detector which will have 30 x 30 cm(2) FOV and cover the 250 MeV proton range with about 150 micron range resolution. These performances are suitable for almost all medical imaging applications.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Development of a Real-Time, Large Area, High Spatial Resolution Particle Tracker Based on Scintillating Fibers
    Lo Presti, D.
    Bonanno, D. L.
    Longhitano, F.
    Pugliatti, C.
    Aiello, S.
    Cirrone, G. A. P.
    Giordano, V.
    Leonora, E.
    Randazzo, N.
    Reito, S.
    Romano, F.
    Russo, G. V.
    Russo, M.
    Sipala, V.
    Stancampiano, C.
    Ventura, C.
    ADVANCES IN HIGH ENERGY PHYSICS, 2014, 2014
  • [2] Corrosion detection and characterization using high resolution real-time radiography
    Bueno, C
    Barker, MD
    Barry, RC
    Betz, RA
    MATERIALS AND PROCESS CHALLENGES: AGING SYSTEMS, AFFORDABILITY, ALTERNATIVE APPLICATIONS, BOOKS 1 AND 2, 1996, 41 (BK 1-2): : 230 - 242
  • [3] Real-time digital radiography system
    Hitachi Review, 2001, (SPECIAL ISSUE):
  • [4] A real-time, high-resolution camera with an amorphous silicon large-area sensor
    Gilblom, D
    Colbeth, R
    Klausmeier-Brown, M
    Allen, M
    DIGITAL SOLID STATE CAMERAS: DESIGN AND APPLICATIONS, 1998, 3302 : 29 - 38
  • [5] LARGE AREA REAL-TIME SYSTEM FOR SCREENING DNA LIBRARIES
    GORDON, JS
    MCGANN, W
    DALEY, K
    MCCONCHIE, L
    SQUILLANTE, MR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (05) : 1485 - 1489
  • [6] REAL-TIME RADIOGRAPHY AND PARTICLE DYNAMICS IN OPTICALLY OPAQUE SUSPENSIONS
    MONDY, LA
    GRAHAM, AL
    BRYANT, LE
    LUCERO, JP
    MATERIALS EVALUATION, 1986, 44 (01) : 120 - 124
  • [7] Design of ultra high resolution real-time display system
    Liu, Yu
    Hu, Ya-Hua
    Lu, Li
    Tang, Bo
    Yu, Li-Fu
    Guofang Keji Daxue Xuebao/Journal of National University of Defense Technology, 2002, 24 (03):
  • [8] Towards an Embedded Real-Time High Resolution Vision System
    Ekstrand, Fredrik
    Ahlberg, Carl
    Ekstrom, Mikael
    Spampinato, Giacomo
    ADVANCES IN VISUAL COMPUTING (ISVC 2014), PT II, 2014, 8888 : 541 - 550
  • [9] Real-Time Compression System for High-Resolution Image
    Deng, Chen-Wei
    Zhao, Bao-Jun
    ICSP: 2008 9TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, VOLS 1-5, PROCEEDINGS, 2008, : 466 - 469
  • [10] Real-time teleconsultation with high resolution and large volume medical imaging
    Zhang, JG
    Stahl, J
    Song, KS
    Huang, HK
    MEDICAL IMAGING 1998 - PACS DESIGN AND EVALUATION: ENGINEERING AND CLINICAL ISSUES, 1998, 3339 : 185 - 190