Advanced Knee Structure Analysis (AKSA): a comparison of bone mineral density and trabecular texture measurements using computed tomography and high-resolution peripheral quantitative computed tomography of human knee cadavers

被引:11
|
作者
Lowitz, Torsten [1 ]
Museyko, Oleg [1 ]
Bousson, Valerie [2 ,3 ]
Chappard, Christine [2 ,3 ]
Laouisset, Liess [2 ,3 ]
Laredo, Jean-Denis [2 ,3 ]
Engelke, Klaus [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, Henkestr 91, D-91052 Erlangen, Germany
[2] Hop Lariboisiere, AP HP, Serv Radiol Osteo Articulaire, 2 Rue Ambroise Pare, F-75475 Paris 10, France
[3] Univ Paris Diderot, Sorbonne Paris Cite, Lab B2OA, CNRS,UMR 7052, F-75010 Paris, France
关键词
Knee OA; Subchondral bone; Texture; Computed tomography; High-resolution peripheral quantitative computed tomography; SUBCHONDRAL BONE; CANCELLOUS BONE; POSTMENOPAUSAL WOMEN; HIP OSTEOARTHRITIS; PROXIMAL TIBIA; MEDIAL CONDYLE; HR-PQCT; STANDARD; CT; MICROARCHITECTURE;
D O I
10.1186/s13075-016-1210-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A change of loading conditions in the knee causes changes in the subchondral bone and may be a cause of osteoarthritis (OA). However, quantification of trabecular architecture in vivo is difficult due to the limiting spatial resolution of the imaging equipment; one approach is the use of texture parameters. In previous studies, we have used digital models to simulate changes of subchondral bone architecture under OA progression. One major result was that, using computed tomography (CT) images, subchondral bone mineral density (BMD) in combination with anisotropy and global homogeneity could characterize this progression. Method: The applicability of texture analysis to characterize bone architecture in clinical CT examinations was investigated and compared to results obtained from HR-pQCT. Fifty-seven human knee cadavers (OA status unknown) were examined with both imaging modalities. Three-dimensional (3D) segmentation and registration processes, together with automatic positioning of 3D analysis volumes of interest (VOIs), ensured the measurement of BMD and texture parameters at the same anatomical locations in CT and HR-pQCT datasets. Results: According to the calculation of dice ratios (> 0.978), the accuracy of VOI locations between methods was excellent. Entropy, anisotropy, and global inhomogeneity showed significant and high linear correlation between both methods (0.68< R-2 < 1.00). The resolution dependence of these parameters simulated earlier was confirmed by the in vitro measurements. Conclusion: The high correlation of HR-pQCT- and CT-based measurements of entropy, global inhomogeneity, and anisotropy suggests interchangeability between devices regarding the quantification of texture. The agreement of the experimentally determined resolution dependence of global inhomogeneity and anisotropy with earlier simulations is an important milestone towards their use to quantify subchondral bone structure. However, an in vivo study is still required to establish their clinical relevance.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Advanced Knee Structure Analysis (AKSA): a comparison of bone mineral density and trabecular texture measurements using computed tomography and high-resolution peripheral quantitative computed tomography of human knee cadavers
    Torsten Lowitz
    Oleg Museyko
    Valérie Bousson
    Christine Chappard
    Liess Laouisset
    Jean-Denis Laredo
    Klaus Engelke
    Arthritis Research & Therapy, 19
  • [2] Accuracy of volumetric bone mineral density measurement in high-resolution peripheral quantitative computed tomography
    Sekhon, Kiranjit
    Kazakia, Galateia J.
    Burghardt, Andrew J.
    Hermannsson, Bryan
    Majumdar, Sharmila
    BONE, 2009, 45 (03) : 473 - 479
  • [3] In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography
    Boutroy, S
    Bouxsein, ML
    Munoz, F
    Delmas, PD
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2005, 90 (12): : 6508 - 6515
  • [4] Influence of soft tissue on bone density and microarchitecture measurements by high-resolution peripheral quantitative computed tomography
    Caksa, Signe
    Yuan, Amy
    Rudolph, Sara E.
    Yu, Elaine W.
    Popp, Kristin L.
    Bouxsein, Mary L.
    BONE, 2019, 124 : 47 - 52
  • [5] Quantitative Evaluation of Knee Subchondral Bone Mineral Density Using Cone Beam Computed Tomography
    Turunen, Mikael J.
    Toyras, Juha
    Kokkonen, Harri T.
    Jurvelin, Jukka S.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (10) : 2186 - 2190
  • [6] In vivo analysis of subchondral trabecular bone in patients with osteoarthritis of the knee using second-generation high-resolution peripheral quantitative computed tomography (HR-pQCT)
    Shiraishi, Kazuteru
    Chiba, Ko
    Okazaki, Narihiro
    Yokota, Kazuaki
    Nakazoe, Yusuke
    Kidera, Kenichi
    Yonekura, Akihiko
    Tomita, Masato
    Osaki, Makoto
    BONE, 2020, 132
  • [7] High-Resolution Peripheral Quantitative Computed Tomography in Rheumatic Diseases A New Option for Knee Osteoarthritis
    Boyd, Steven K.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2024, 62 (05) : 903 - 912
  • [8] Microstructural analysis of subchondral trabecular bone in patients with osteoarthritis of the knee using second-generation high-resolution peripheral quantitative computed tomography (HR-pQCT)
    Shiraishi, Kazuteru
    Chiba, Ko
    Okazaki, Narihiro
    Yokota, Kazuaki
    Osaki, Makoto
    JOURNAL OF BONE AND MINERAL RESEARCH, 2019, 34 : 88 - 89
  • [9] Tibial subchondral trabecular volumetric bone density in medial knee joint osteoarthritis using peripheral quantitative computed tomography technology
    Bennell, Kim L.
    Creaby, Mark W.
    Wrigley, Tim V.
    Hunter, David J.
    ARTHRITIS AND RHEUMATISM, 2008, 58 (09): : 2776 - 2785
  • [10] IN-VIVO ASSESSEMENT OF VOLUMETRIC BONE MINERAL DENSITY AND TRABECULAR ARCHITECTURE BY HIGH-RESOLUTION PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY (HR-PQCT)
    Bogado, C.
    Mango, A.
    Zanchetta, J.
    OSTEOPOROSIS INTERNATIONAL, 2009, 20 : 137 - 137