Comparison of real-time virtual and fiberoptic bronchoscopy in patients with bronchial carcinoma: Opportunities and limitations

被引:88
|
作者
Fleiter, T [1 ]
Merkle, EM [1 ]
Aschoff, AJ [1 ]
Lang, G [1 ]
Stein, M [1 ]
Gorich, J [1 ]
Liewald, F [1 ]
Rilinger, N [1 ]
Sokiranski, R [1 ]
机构
[1] UNIV ULM,DEPT VASC & THORAC SURG,D-89075 ULM,GERMANY
关键词
D O I
10.2214/ajr.169.6.9393172
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Both helical CT and fiberoptic bronchoscopy are used in the staging of pulmonary tumors for therapeutic decision making. The improved resolution offered by helical CT has led to the clinical use of three-dimensional reconstruction techniques such as virtual bronchoscopy. We tested this new simulated endoscopic view of inner organ surfaces and compared it with corresponding fiberoptic examinations of the tracheobronchial system. SUBJECTS AND METHODS. Twenty patients with malignancies of the lung and mediastinum were examined with both virtual bronchoscopy and fiberoptic bronchoscopy. Both examinations were reviewed by radiologists and surgeons familiar with fiberoptic bronchoscopy. Virtual bronchoscopy was calculated and reconstructed from the cross-sectional images on a separate workstation. Stenoses and tumor infiltration were classified from the fiberoptic examination. These results were compared with the virtual bronchoscopy findings, RESULTS, Virtual bronchoscopy of diagnostic quality was achieved in 19 of 20 patients. High-grade stenoses were revealed equally well with virtual and fiberoptic techniques. Virtual bronchoscopy offered the advantage of being able to visualize areas beyond even high-grade stenoses. However, on virtual bronchoscopy discrete infiltration or extraluminal impression was not visible in five patients. In Mother patient, strong heart pulsation produced motion artifacts that prevented evaluation of the reconstruction. CONCLUSION, Virtual bronchoscopy represents a new noninvasive method for evaluating helical CT findings. In comparison with fiberoptic bronchoscopy, virtual bronchoscopy offers the advantage of being able to visualize areas beyond even high-grade stenoses, In addition to the limited view of fiberoptic bronchoscopy, extraluminal causes of lumen compressions can be analyzed in the cross-sectional images and evaluated together with the virtual representation. However, it was not possible to detect small infiltrations with virtual bronchoscopy. This new representation of helical CT data might be helpful for postoperative follow-up examinations, such as after stent implantation, and can be carried out without additional risk to the patient. Radiologists do need special fiberoptic bronchoscopy knowledge and experience with three-dimensional reconstructions to differentiate between real stenoses and artificial stenoses that might be caused by pulsation artifacts.
引用
收藏
页码:1591 / 1595
页数:5
相关论文
共 50 条
  • [1] Comparison of virtual and fiberoptic bronchoscopy
    Liewald, F
    Lang, G
    Fleiter, T
    Sokiranski, R
    Halter, G
    Orend, KH
    THORACIC AND CARDIOVASCULAR SURGEON, 1998, 46 (06): : 361 - 364
  • [2] COMPARISON BETWEEN FIBEROPTIC AND RIGID BRONCHOSCOPY IN THE DIAGNOSIS OF BRONCHIAL-CARCINOMA
    SUMMERS, G
    LYALL, J
    OBRIEN, I
    BRAIMBRIDGE, MV
    THORAX, 1980, 35 (01) : 77 - 77
  • [3] Navigational aids for real-time virtual bronchoscopy
    Summers, RM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (05) : 1165 - 1170
  • [4] FLEXIBLE FIBEROPTIC BRONCHOSCOPY IN DIAGNOSIS OF BRONCHIAL-CARCINOMA
    LUNDGREN, R
    LUNDQVIST, G
    STJERNBERG, N
    THUNELL, M
    SCANDINAVIAN JOURNAL OF RESPIRATORY DISEASES, 1976, 57 (05): : 247 - 251
  • [5] Comparison of virtual bronchoscopy with fiberoptic bronchoscopy findings in patients exposed to sulfur mustard gas
    Akhlaghpoor, Shahram
    Ahari, Alireza Aziz
    Shabestari, Abbas Arjmand
    Ghanei, Mostafa
    Ali, Hamideh Ale
    Shakiba, Madjid
    ACTA RADIOLOGICA, 2011, 52 (10) : 1095 - 1100
  • [6] Multidetector computed tomography virtual bronchoscopy: comparison with fiberoptic bronchoscopy
    Sodhi, Kushaljit Singh
    Saxena, Akshay Kumar
    Vyas, Sameer
    Khandelwal, Niranjan
    ACTA RADIOLOGICA, 2012, 53 (03) : 366 - 366
  • [7] COMPARISON OF CT AND FIBEROPTIC BRONCHOSCOPY IN THE EVALUATION OF BRONCHIAL DISEASE
    NAIDICH, DP
    LEE, JJ
    GARAY, SM
    MCCAULEY, DI
    ARANDA, CP
    BOYD, AD
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (01) : 1 - 7
  • [8] Comparison of CT and Fiberoptic Bronchoscopy in the Evaluation of Bronchial Disease
    夏锡荣
    宋兆琪
    康晓明
    孙正明
    金陵医院院刊 , 1990, (03) : 276 - 280
  • [9] Virtual bronchoscopy: Segmentation method for real-time display
    Summers, RM
    Feng, DH
    Holland, SM
    Sneller, MC
    Shelhamer, JH
    RADIOLOGY, 1996, 200 (03) : 857 - 862
  • [10] Comparison of virtual and fiberoptic bronchoscopy in the management of airway stenosis
    Mark, Zsuzsa
    Bajzik, Gabor
    Nagy, Andrea
    Bogner, Peter
    Repa, Imre
    Strausz, Janos
    PATHOLOGY & ONCOLOGY RESEARCH, 2008, 14 (03) : 313 - 319