Incremental diagnostic value of combined quantitative and qualitative parameters of magnetocardiography to detect coronary artery disease

被引:18
|
作者
Shin, Eun-Seok [1 ]
Lam, Yat-Yin [2 ]
Her, Ae-Young [3 ]
Brachmann, Johannes [4 ]
Jung, Friedrich [5 ]
Park, Jai-Wun [4 ]
机构
[1] Univ Ulsan, Ulsan Univ Hosp, Coll Med, Dept Cardiol, Ulsan, South Korea
[2] Chinese Univ Hong Kong, Prince Wales Hosp, Hong Kong, Hong Kong, Peoples R China
[3] Kangwon Natl Univ, Sch Med, Dept Internal Med, Div Cardiol, Chunchon, South Korea
[4] Coburg Hosp, Dept Med 2, Coburg, Germany
[5] Helmholtz Zentrum Geesthacht, Inst Biomat Sci & Berlin Brandenburg, BCRT, Ctr Regenerat Therapies, Teltow, Germany
关键词
Magnetocardiography; Coronary artery disease; Myocardial ischemia; ST-segment fluctuation score; Non-dipole phenomenon; MYOCARDIAL-ISCHEMIA; HEART-DISEASE; ST-SEGMENT; FRAGMENTATION; POTENTIALS; COMPLEX; STRESS; WAVE;
D O I
10.1016/j.ijcard.2016.11.165
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/objectives: Magnetocardiography (MCG) has been proposed as a non-invasive and functional technique with high accuracy for diagnosis of myocardial ischemia. This study sought to investigate the incremental diagnostic value of combined quantitative and qualitative parameters of MCG to detect coronary artery disease (CAD). Methods: Ninety six patients with suspected CAD who underwent coronary angiography were enrolled in the analysis to test the diagnostic accuracy of 2 MCG parameters (a quantitative parameter of the percent change of ST-segment fluctuation score and a qualitative parameter of non-dipole phenomenon). Results: The best cut-off value for the percent change of ST-segment fluctuation score was-51.0%. The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were 78.1, 73.9, 82.0, 79.1, and 77.4, in the percent change of ST-segment fluctuation score and 86.5, 84.8, 88.0, 86.7, and 86.3 in non-dipole phenomenon. The area under the curve of receiver-operating characteristics was 0.79 for the percent change of ST-segment fluctuation score and 0.86 for non-dipole phenomenon (p < 0.001). However, the incorporation of non-dipole phenomenon into a model with the percent change of ST-segment fluctuation score significantly improved C-statistics, indicating the enhancement of diagnostic performance in the detection of significant CAD (0.790 to 0.930; p < 0.001). Conclusions: Qualitative assessment of non-dipole phenomenon has a better diagnostic value than the quantitative parameter of percent change of ST-segment fluctuation score in the detection of significant CAD. Furthermore, this study found that the incorporation of non-dipole phenomenon into the percent change of ST-segment fluctuation score significantly improved the diagnostic performance of CAD detection. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:948 / 952
页数:5
相关论文
共 50 条
  • [1] Value of magnetocardiography in the diagnosis of coronary artery disease
    Berndt, C.
    Chaikovsky, I.
    Korfer, J.
    Horstkotte, D.
    EUROPEAN HEART JOURNAL, 2006, 27 : 323 - 324
  • [2] Diagnostic outcomes of magnetocardiography in patients with coronary artery disease
    Li, Yingmei
    Che, Zaiqian
    Quan, Weiwei
    Yuan, Rong
    Shen, Yue
    Liu, Zongjun
    Wang, Weiqing
    Jin, Huigen
    Lu, Guoping
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (02): : 2441 - 2446
  • [3] Diagnostic value of magnetocardiography in coronary artery disease and cardiac arrhythmias: A review of clinical data
    Kwong, Joey S. W.
    Leithaeuser, Boris
    Park, Jai-Wun
    Yu, Cheuk-Man
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (05) : 1835 - 1842
  • [4] Usefulness of Magnetocardiography to Detect Coronary Artery Disease and Cardiac Allograft Vasculopathy
    Wu, Yen-Wen
    Lee, Chii-Ming
    Liu, Yen-Bin
    Wang, Shoei-Shen
    Huang, Hui-Chun
    Tseng, Wei-Kung
    Jui, Hsiang-Yiang
    Wang, Shan-Ying
    Horng, Herng-Er
    Yang, Hong-Chang
    Wu, Chau-Chung
    CIRCULATION JOURNAL, 2013, 77 (07) : 1783 - 1790
  • [5] The Diagnostic Value of Treadmill Exercise Test Parameters for Coronary Artery Disease
    Sun, Jian Ling
    Han, Rong
    Guo, Ji Hong
    Li, Xiao Ying
    Ma, Xian Lin
    Wang, Chong Yu
    CELL BIOCHEMISTRY AND BIOPHYSICS, 2013, 65 (01) : 69 - 76
  • [6] The Diagnostic Value of Treadmill Exercise Test Parameters for Coronary Artery Disease
    Jian Ling Sun
    Rong Han
    Ji Hong Guo
    Xiao Ying Li
    Xian Lin Ma
    Chong Yu Wang
    Cell Biochemistry and Biophysics, 2013, 65 : 69 - 76
  • [7] Incremental diagnostic value of circulating pentraxin in patients with intermediate risk of coronary artery disease
    Haybar, Habib
    Assareh, Ahmadreza
    Ghotbi, Yasaman
    Torabizadeh, Mehdi
    Bozorgmanesh, Mohammadreza
    HEART, 2013, 99 (09) : 640 - 648
  • [8] Diagnostic value of magnetocardiography in patients with coronary heart disease and in-stent restenosis
    QUAN Weiwei LU Guoping QI Wenhang LI Yingmei SHEN Yue and YUAN Rong Department of CardiologyRui Jin HospitalMedical College of Shanghai Jiao Tong UniversityShanghai China Shanghai Putuo District Center HospitalShanghai China
    中华医学杂志(英文版), 2008, (01) : 22 - 26
  • [9] Incremental diagnostic performance of combined parameters in the detection of severe coronary artery disease using exercise gated myocardial perfusion imaging
    Liu, Chia-Ju
    Wu, Yen-Wen
    Cheng, Mei-Fang
    Yen, Ruoh-Fang
    Tzen, Kai-Yuan
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [10] Incremental Diagnostic Performance of Combined Parameters in the Detection of Severe Coronary Artery Disease Using Exercise Gated Myocardial Perfusion Imaging
    Liu, Chia-Ju
    Wu, Yen-Wen
    Ko, Kuan-Yin
    Chen, Yi-Chieh
    Cheng, Mei-Fang
    Yen, Ruoh-Fang
    Tzen, Kai-Yuan
    PLOS ONE, 2015, 10 (07):