Feasibility of a novel self-collection method for blood samples and its acceptability for future home-based PrEP monitoring

被引:15
|
作者
Cannon, Chase A. [1 ]
Ramchandani, Meena S. [1 ]
Golden, Matthew R. [1 ,2 ]
机构
[1] Univ Washington, Dept Med, 325 9th Ave,Box 359777, Seattle, WA USA
[2] Publ Hlth Seattle King Cty, HIV STD Program, 325 9th Ave,Box 359777, Seattle, WA USA
基金
美国国家卫生研究院;
关键词
PrEP; Home sampling; Blood self-collection; Syphilis; DEVICE; CARE; HIV;
D O I
10.1186/s12879-022-07432-0
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background Most non-clinic based HIV pre-exposure prophylaxis (PrEP) programs require fingersticks to self-collect blood specimens for laboratory monitoring, a technique that often results in inadequate blood volume for quantitative syphilis and HIV serological testing. We evaluated the acceptability and feasibility of using the Tasso OnDemand (TM) device as a self-sampling method for PrEP monitoring tests and compared results from samples obtained using the Tasso device to clinician-collected blood samples. Methods We enrolled study subjects online and in a sexual health clinic and HIV clinic in Seattle, WA, USA to assess the acceptability of blood self-sampling and preferences for home-based PrEP monitoring. We compared HIV antigen/antibody, quantitative rapid plasma reagin and creatinine results in paired self-collected and clinical specimens collected from a subset of participants. Results Of 141 participants, 124 (88%) were interested in collecting samples for PrEP monitoring at home. Among 48 who completed blood collections, 94% found the Tasso device easy to use and 95% felt they could perform self-sampling at home. Of 27 participants who used two devices, 100% collected sufficient blood to perform up to two tests while 33% collected sufficient serum for three tests. Agreement in test results between paired samples was high. Conclusions These pilot data suggest that using the Tasso self-collection device is acceptable and could feasibly be used to obtain serum specimens sufficient for guideline-recommended PrEP monitoring, though use of a larger volume device may be preferable.
引用
收藏
页数:8
相关论文
共 44 条
  • [1] Feasibility of a novel self-collection method for blood samples and its acceptability for future home-based PrEP monitoring
    Chase A. Cannon
    Meena S. Ramchandani
    Matthew R. Golden
    BMC Infectious Diseases, 22
  • [2] A NEW METHOD FOR SELF-COLLECTION OF BLOOD SPECIMENS FOR HIV PRE-EXPOSURE PROPHYLAXIS (PREP) LABORATORY MONITORING
    Cannon, C.
    Malinski, C.
    Golden, M.
    SEXUALLY TRANSMITTED INFECTIONS, 2021, 97 : A90 - A90
  • [3] Capillary blood based self-collection device for infliximab therapeutic drug monitoring
    Law, C.
    Djalal, A.
    Hopkins, M.
    Trick, D.
    Kang, D.
    Brady, K.
    Tucker, D.
    Everts-van der Wind, A.
    Dervieux, T.
    Colombel, J. F.
    JOURNAL OF CROHNS & COLITIS, 2024, 18 : I1095 - I1096
  • [4] Acceptability and Feasibility of Community-Based, Lay Navigator-Facilitated At-Home Self-Collection for Human Papillomavirus Testing in Underscreened Women
    Mitchell, Emma McKim
    Lothamer, Heather
    Garcia, Christine
    Des Marais, Andrea
    Camacho, Fabian
    Poulter, Melinda
    Bullock, Linda
    Smith, Jennifer S.
    JOURNAL OF WOMENS HEALTH, 2020, 29 (04) : 596 - 602
  • [5] An exploratory assessment of the feasibility and acceptability of home-based support to streamline HIV pre-exposure prophylaxis (PrEP) delivery
    Siegler, A.
    Liu, A.
    Mayer, K.
    Thure, K.
    Fish, R.
    Andrew, E.
    Gelman, M.
    Sullivan, P.
    JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2016, 19
  • [6] Acceptability of Home-Based Urine Self-Collection for Cervical Cancer Screening Among Women Receiving Care at the Arab Community Center for Economic and Social Services in Michigan
    Guetterman, Timothy C.
    El Khoury, Christelle
    Tariq, Madiha
    Aziz, Ghada
    Alhawli, Asraa
    Alves, Martha L.
    Haro, Elizabeth
    Butcher, Emma A.
    Vinson, Alexandra H.
    Harper, Diane M.
    CANCER MEDICINE, 2025, 14 (04):
  • [7] Digital Home-Based Self-Monitoring System for People with Heart Failure: Protocol for Development of SmartHeart and Evaluation of Feasibility and Acceptability
    Maddison, Ralph
    Nourse, Rebecca
    Daryabeygikhotbehsara, Reza
    Tegegne, Teketo Kassaw
    Jansons, Paul
    Rawstorn, Jonathan Charles
    Atherton, John
    Driscoll, Andrea
    Oldenburg, Brian
    Vasa, Rajesh
    Kostakos, Vassilis
    Dingler, Tilman
    Abbott, Gavin
    Scuffham, Paul
    Manski-Nankervis, Jo-Anne Elizabeth
    Kwasnicka, Dominika
    Kensing, Finn
    Islam, Sheikh Mohammed Shariful
    Maeder, Anthony
    Zhang, Yuxin
    JMIR RESEARCH PROTOCOLS, 2025, 14
  • [8] Feasibility and acceptability of home-based self-collection of multiple vaginal swabs in a general population survey in Britain′s fourth National Survey of Sexual Attitudes and Lifestyles-4 (Natsal-4)
    Oeser, Clarissa
    Beddows, Simon
    Chang, Gwendolyn
    Clifton, Soazig
    Conolly, Anne
    David, Alexandra
    Dema, Emily
    Field, Nigel
    Gibbs, Jo
    Hamilton, Rebecca
    Light, Rebecca
    Mercer, Catherine H.
    Panwar, Kavita
    Roodt, Abraham
    Sadler, Katherine
    Sonnenberg, Pam
    Unemo, Magnus
    SEXUALLY TRANSMITTED DISEASES, 2024, 51 (01) : S318 - S319
  • [9] HOME-BASED SELF-COLLECTION FOR THE DETECTION OF SEXUALLY TRANSMITTED INFECTIONS IN HIGH-RISK WOMEN IN NORTH CAROLINA
    Des Marais, Andrea
    Senkomago, Virginia
    Hill, Craig
    Barclay, Lynn
    Smith, Jennifer
    SEXUALLY TRANSMITTED DISEASES, 2014, 41 : S26 - S26
  • [10] FEASIBILITY AND ACCEPTABILITY OF A NOVEL HOME-BASED ORAL GLUCOSE TOLERANCE TEST USING CONTINUOUS GLUCOSE MONITORING FOR THE DIAGNOSIS OF GESTATIONAL DIABETES
    Meek, C.
    Brown, J.
    Hughes, D.
    Kusinski, L.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : A69 - A69