Microrheology with Fluorescence Correlation Spectroscopy

被引:30
|
作者
Rathgeber, Silke [1 ,2 ]
Beauvisage, Hans-Josef [1 ]
Chevreau, Hubert [1 ,3 ]
Willenbacher, Norbert [4 ]
Oelschlaeger, Claude [4 ]
机构
[1] Max Planck Inst Polymer Res, D-55128 Mainz, Germany
[2] Johannes Gutenberg Univ Mainz, Inst Phys, D-55099 Mainz, Germany
[3] Univ Lille, Ecole Polytech, F-59655 Villeneuve Dascq, France
[4] Tech Univ Karlsruhe, D-76131 Karlsruhe, Germany
关键词
VISCOELASTIC MODULI; COMPLEX; RHEOLOGY; BEHAVIOR;
D O I
10.1021/la804170k
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We show that fluorescence correlation spectroscopy (FCS) using a commercial spectrometer can be applied to passive microrheological (MR) experiments. The method probes the local rheological properties of materials on length scales of the focus dimension of the confocal microscope. For a feasibility study, we performed measurements on a high molecular weight poly(ethylene oxide)-water solution to allow direct comparison of the results to previous studies using diffusing wave spectroscopy, quasielastic light scattering, and particle tracking methods. We were able to detect mean-square center-of-mass displacements ranging from somewhat better than <Delta r(2)(t)> approximate to 100 nm(2) up to above <Delta r(2)(t)> approximate to 10(6) nm(2). Thus, we were able to derive the bulk rheological shear moduli covering more than Five decades in frequency (from omega <= 10(-1) rad/s to omega approximate to 10(4) rad/s). The MR results are compared to results obtained from conventional rheological experiments on the same samples using a rotational rheometer as well as a piezo-driven squeeze flow apparatus. Good agreement between MR results probing the local rheological properties and those obtained by the conventional methods measuring the macroscopic mechanical response is found in the whole frequency range. Spatial resolution in combination with the possibility of using small tracer beads open the opportunity to probe the local, length scale-dependent rheological properties in heterogeneous samples. Small tracer concentrations and small sample sizes make FCS spectroscopy a powerful tool in particular for biological and medical applications.
引用
收藏
页码:6368 / 6376
页数:9
相关论文
共 50 条
  • [1] COLL 184-Microrheology of polymer solutions using fluorescence correlation spectroscopy
    Gosh, R. C.
    Tanaka, S.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 238
  • [2] Image correlation spectroscopy as a tool for microrheology of soft materials
    Kurniawan, Nicholas Agung
    Lim, Chwee Teck
    Rajagopalan, Raj
    SOFT MATTER, 2010, 6 (15) : 3499 - 3505
  • [3] Fluorescence correlation spectroscopy and fluorescence cross-correlation spectroscopy
    Digman, Michelle A.
    Gratton, Enrico
    WILEY INTERDISCIPLINARY REVIEWS-SYSTEMS BIOLOGY AND MEDICINE, 2009, 1 (02) : 273 - 282
  • [4] Fluorescence correlation spectroscopy
    Webb, WW
    PHOTON CORRELATION AND SCATTERING, TECHNICAL DIGEST, 2000, 47 : 4 - 6
  • [5] Fluorescence correlation spectroscopy
    Ries, Jonas
    Schwille, Petra
    BIOESSAYS, 2012, 34 (05) : 361 - 368
  • [6] Fluorescence correlation spectroscopy
    Müller, JD
    Chen, Y
    Gratton, E
    BIOPHOTONICS, PT B, 2003, 361 : 69 - 92
  • [7] FLUORESCENCE CORRELATION SPECTROSCOPY
    WEBB, WW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (03): : 197 - 197
  • [8] Fluorescence Correlation Spectroscopy
    Beranova, Lenka
    Humpolickova, Jana
    Hof, Martin
    CHEMICKE LISTY, 2009, 103 (02): : 125 - 129
  • [9] Fluorescence correlation spectroscopy in vivo
    Muetze, Joerg
    Ohrt, Thomas
    Schwille, Petra
    LASER & PHOTONICS REVIEWS, 2011, 5 (01) : 52 - 67
  • [10] Fluorescence correlation spectroscopy on a mirror
    Rigneault, H
    Lenne, PF
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2003, 20 (10) : 2203 - 2214