Single-scan z-shim method for reducing susceptibility artifacts in gradient echo myelin water imaging

被引:10
|
作者
Lee, Doohee [1 ]
Lee, Jingu [1 ]
Lee, Jongho [1 ]
Nam, Yoonho [2 ]
机构
[1] Seoul Natl Univ, Dept Elect & Comp Engn, Seoul, South Korea
[2] Catholic Univ Korea, Seoul St Marys Hosp, Dept Radiol, Coll Med, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
field inhomogeneity; gradient echo; magnetic susceptibility artifact; myelin water imaging; z-shim; MACROSCOPIC FIELD INHOMOGENEITY; EXPONENTIAL EXCITATION PULSES; BACKGROUND GRADIENTS; WHITE-MATTER; MULTIPLE-SCLEROSIS; T-2-ASTERISK DECAY; COMPENSATION; IMAGES; BRAIN; MRI;
D O I
10.1002/mrm.27127
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeMyelin water imaging (MWI) reportedly corresponds closely to the myelin content in the brain. An MWI technique based on multi-echo gradient echo (mGRE) has recently been proposed as an alternative to the conventional spin-echo-based MWI. However, the mGRE signal is vulnerable to macroscopic field inhomogeneity, which makes MWI unreliable. In the present study, a z-shim-based single-scan correction method is proposed to overcome this limitation. MethodsZ-shim gradients in the slice-selection direction were added to an mGRE sequence after an echo time of 12 ms. A 3-pool model corresponding to the proposed sequence was suggested for fitting the acquired signal. The method was evaluated through a comparison with methods without a correction and with post-processing only from non-z-shimmed data. To do this, numerical simulations and in vivo experiments were conducted. ResultsThe simulation and in vivo experiment results indicated that post-processing alone was not sufficient to offset the macroscopic field inhomogeneity, particularly in inferior regions of the brain. On the other hand, the proposed method compensated the field inhomogeneity in most brain areas. The estimated in vivo myelin water fraction values were in good agreement with literature values obtained by previously proposed field inhomogeneity correction method. ConclusionThe proposed method showed reliable myelin water fraction in most regions of the brain in vivo, including those with severe field inhomogeneity.
引用
收藏
页码:1101 / 1109
页数:9
相关论文
共 11 条
  • [1] Simultaneous Z-Shim Method for Reducing Susceptibility Artifacts With Multiple Transmitters
    Deng, Weiran
    Yang, Cungeng
    Alagappan, Vijayanand
    Wald, Lawrence L.
    Boada, Fernando E.
    Stenger, V. Andrew
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) : 255 - 259
  • [2] Reducing susceptibility artifacts in fMRI using volume-selective z-shim compensation
    Du, Yiping P.
    Dalwani, Manish
    Wylie, Korey
    Claus, Eric
    Tregellas, Jason R.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (02) : 396 - 404
  • [3] Volumetric R2* Mapping Using Z-shim Multi-Echo Gradient Echo Imaging
    Han, Dongyeob
    Nam, Yoonho
    Gho, Sung-Min
    Kim, Dong-Hyun
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (03) : 1164 - 1170
  • [4] Simultaneous acquisition of gradient-echo and asymmetric spin-echo for single-shot z-shim: Z-SAGA
    Heberlein, KA
    Hu, XP
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) : 212 - 216
  • [5] A METHOD FOR Z-SHIM COMPENSATED EPI-BOLD IMAGING IN A SINGLE SHOT
    Hoge, W. Scott
    Kraft, Robert A.
    Stern, Emily
    Pan, Hong
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 338 - 341
  • [6] Single, slice-specific z-shim gradient pulses improve T2*-weighted imaging of the spinal cord
    Finsterbusch, Juergen
    Eippert, Falk
    Buechel, Christian
    NEUROIMAGE, 2012, 59 (03) : 2307 - 2315
  • [7] Simultaneous perfusion and blood-oxygenation-level-dependent measurements using single-shot interleaved z-shim echo-planar imaging
    Yang, YH
    Gu, H
    Silbersweig, DA
    Stern, E
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) : 1207 - 1211
  • [8] A Single-Scan T2* Mapping Method Based on Two Gradient-Echo Images with Compensation for Macroscopic Field Inhomogeneity
    Meng, Yuguang
    Lei, Hao
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) : 1388 - 1395
  • [9] Automated Slice-Specific Simultaneous Z-Shim Method for Reducing B1 Inhomogeneity and Susceptibility-Induced Signal Loss with Parallel Transmission at 3T
    Schneider, Rainer
    Boada, Fernando
    Haueisen, Jens
    Pfeuffer, Josef
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (04) : 934 - 944
  • [10] Dual-echo spiral in/in acquisition method for reducing magnetic susceptibility artifacts in blood-oxygen-level-dependent functional magnetic resonance imaging
    Li, TQ
    Takahashi, A
    Wang, Y
    Mathews, V
    Glover, GH
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (02) : 325 - 334