Feasibility of stereotactic body radiation therapy with volumetric modulated arc therapy and high intensity photon beams for hepatocellular carcinoma patients

被引:27
|
作者
Wang, Po-Ming [1 ]
Hsu, Wei-Chung [1 ,2 ]
Chung, Na-Na [1 ]
Chang, Feng-Ling [1 ]
Jang, Chin-Jyh [1 ]
Fogliata, Antonella [3 ]
Scorsetti, Marta [4 ]
Cozzi, Luca [3 ]
机构
[1] Cheng Ching Gen Hosp, Chung Kang Branch, Dept Radiat Oncol, Taichung, Taiwan
[2] Asia Univ, Dept Healthcare Adm, Taichung, Taiwan
[3] Oncol Inst Southern Switzerland, Bellinzona, Switzerland
[4] Ist Clin Humanitas, Rozzano, Italy
来源
RADIATION ONCOLOGY | 2014年 / 9卷
关键词
Hepatocelluar carcinoma; RapidArc; VMAT; SBRT; Flattening filter free beams; PHASE-I; RADIOTHERAPY; LIVER; CONFORMITY;
D O I
10.1186/1748-717X-9-18
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To report technical features, early outcome and toxicity of stereotactic body radiation therapy (SBRT) treatments with volumetric modulated arc therapy (RapidArc) for patients with hepatocellular carcinoma (HCC). Methods: Twenty patients (22 lesions) were prospectively enrolled in a feasibility study. Dose prescription was 50Gy in 10 fractions. Seven patients (35%) were classified as AJCC stage I-II while 13 (65%) were stages III-IV. Eighteen patients (90%) were Child-Pugh stage A, the remaining were stage B. All patients were treated with RapidArc technique with flattening filter free (FFF) photon beams of 10MV from a TrueBeam linear accelerator. Technical, dosimetric and early clinical assessment was performed to characterize treatment and its potential outcome. Results: Median age was 68 years, median initial tumor volume was 124 cm(3) (range: 6-848). Median follow-up time was 7.4 months (range: 3-13). All patients completed treatment without interruption. Mean actuarial overall survival was of 9.6+/-0.9 months (95%C.L. 7.8-11.4), median survival was not reached; complete response was observed in 8/22 (36.4%) lesions; partial response in 7/22 (31.8%), stable disease in 6/22 (27.3%), 1/22 (4.4%) showed progression. Toxicity was mild with only 1 case of grade 3 RILD and all other types were not greater than grade 2. Concerning dosimetric data, Paddick conformity index was 0.98 +/- 0.02; gradient index was 3.82 +/- 0.93; V-95% to the clinical target volume was 93.6 +/- 7.7%. Mean dose to kidneys resulted lower than 3.0Gy; mean dose to stomach 4.5 +/- 3.0Gy; D-icm(3) to spinal cord was 8.2 +/- 4.5Gy; D-1% to the esophagus was 10.2 +/- 9.7Gy. Average beam on time resulted 0.7 +/- 0.2 minutes (range: 0.4-1.4) with the delivery of an average of 4.4 partial arcs (range: 3-6) of those 86% non-coplanar. Conclusions: Clinical results could suggest to introduce VMAT-RapidArc as an appropriate SBRT technique for patients with HCC in view of a prospective dose escalation trial.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Feasibility of stereotactic body radiation therapy with volumetric modulated arc therapy and high intensity photon beams for hepatocellular carcinoma patients
    Po-Ming Wang
    Wei-Chung Hsu
    Na-Na Chung
    Feng-Ling Chang
    Chin-Jyh Jang
    Antonella Fogliata
    Marta Scorsetti
    Luca Cozzi
    [J]. Radiation Oncology, 9
  • [2] Dosimetric comparison of volumetric modulated arc therapy with robotic stereotactic radiation therapy in hepatocellular carcinoma
    Paik, Eun Kyung
    Kim, Mi-Sook
    Choi, Chul Won
    Il Jang, Won
    Lee, Sung Hyun
    Choi, Sang Hyoun
    Kim, Kum Bae
    Lee, Dong Han
    [J]. RADIATION ONCOLOGY JOURNAL, 2015, 33 (03): : 233 - 241
  • [3] Volumetric modulated arc therapy is superior to intensity modulated radiotherapy for liver sparing in stereotactic body radiotherapy for hepatocellular carcinoma
    Kundel, Y.
    Korzets, Y.
    Weinstock-Sabbah, M.
    Moor, A.
    Gordon, N.
    Bragilovski, D.
    Stemmer, S.
    Popovtzer, A.
    Brenner, B.
    Fenig, E.
    Allen, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1022 - S1022
  • [4] Stereotactic body radiation therapy for abdominal targets using volumetric intensity modulated arc therapy with RapidArc: Feasibility and clinical preliminary results
    Scorsetti, Marta
    Bignardi, Mario
    Alongi, Filippo
    Fogliata, Antonella
    Mancosu, Pietro
    Navarria, Piera
    Castiglioni, Simona
    Pentimalli, Sara
    Tozzi, Angelo
    Cozzi, Luca
    [J]. ACTA ONCOLOGICA, 2011, 50 (04) : 528 - 538
  • [5] Stereotactic body radiation therapy using a respiratory-gated volumetric-modulated arc therapy technique for small hepatocellular carcinoma
    Yuri Jeong
    Jinhong Jung
    Byungchul Cho
    Jungwon Kwak
    Chiyoung Jeong
    Jong Hoon Kim
    Jin-hong Park
    So Yeon Kim
    Ju Hyun Shim
    Kang Mo Kim
    Young-Suk Lim
    Han Chu Lee
    Sang Min Yoon
    [J]. BMC Cancer, 18
  • [6] Stereotactic body radiation therapy using a respiratory-gated volumetric-modulated arc therapy technique for small hepatocellular carcinoma
    Jeong, Yuri
    Jung, Jinhong
    Cho, Byungchul
    Kwak, Jungwon
    Jeong, Chiyoung
    Kim, Jong Hoon
    Park, Jin-hong
    Kim, So Yeon
    Shim, Ju Hyun
    Kim, Kang Mo
    Lim, Young-Suk
    Lee, Han Chu
    Yoon, Sang Min
    [J]. BMC CANCER, 2018, 18
  • [7] Dosimetric comparison of volumetric modulated arc therapy and intensity-modulated radiation therapy for liver stereotactic ablative body radiotherapy
    Thibault, Isabelle
    Wronski, Matt
    Korol, Renee
    Chu, William
    Helou, Joelle
    Erler, Darby
    Chung, Hans T.
    [J]. JOURNAL OF RADIATION ONCOLOGY, 2016, 5 (01) : 63 - 69
  • [8] Dosimetric Evaluation of Noncoplanar Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Delivery Techniques for Cervical Stereotactic Body Radiation Therapy Treatments
    Cohen, D.
    Delgado, A. Brito
    Eng, T. Y.
    Gutierrez, A. N.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E666 - E667
  • [9] Volumetric Modulated Arc Therapy for Stereotactic Body Radiation Therapy: Initial Clinical Experience
    Matuszak, M.
    Yan, D.
    Grills, I.
    Martinez, A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S723 - S724
  • [10] Intensity modulated radiation therapy versus volumetric intensity modulated arc therapy
    Rana, Suresh
    [J]. JOURNAL OF MEDICAL RADIATION SCIENCES, 2013, 60 (03): : 81 - 83