Development and validation of a bioanalytical method for the quantification of the CDK4/6 inhibitors abemaciclib, palbociclib, and ribociclib in human and mouse matrices using liquid chromatography-tandem mass spectrometry

被引:48
|
作者
Martinez-Chavez, Alejandra [1 ,2 ]
Rosing, Hilde [1 ]
Hillebrand, Michel [1 ]
Tibben, Matthijs [1 ]
Schinkel, Alfred H. [2 ]
Beijnen, Jos H. [1 ,2 ,3 ]
机构
[1] Netherlands Canc Inst, Dept Pharm & Pharmacol, Plesmanlaan 121, NL-1066 CX Amsterdam, Netherlands
[2] Netherlands Canc Inst, Div Pharmacol, Plesmanlaan 121, NL-1066 CX Amsterdam, Netherlands
[3] Univ Utrecht, Div Pharmacoepidemiol & Clin Pharmacol, Utrecht Inst Pharmaceut Sci, David de Wied Bldg,Univ Weg 99, NL-3584 CG Utrecht, Netherlands
关键词
Abemaciclib; Palbociclib; Ribociclib; LC-MS; MS; Plasma; Tissue homogenates; QUANTITATIVE-ANALYSIS; PD; 0332991; CANCER; PLASMA; TISSUE;
D O I
10.1007/s00216-019-01932-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel method was developed and validated for the quantification of the three approved CDK4/6 inhibitors (abemaciclib, palbociclib, and ribociclib) in both human and mouse plasma and mouse tissue homogenates (liver, kidney, spleen, brain, and small intestine) using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). For all matrices, pretreatment was performed using 50 mu L of sample by protein precipitation with acetonitrile, followed by dilution of the supernatant. Chromatographic separation of the analytes was done on a C18 column using gradient elution. A full validation was performed for human plasma, while a partial validation was executed for mouse plasma and mouse tissue homogenates. The method was linear in the calibration range from 2 to 200ng/mL, with a correlation coefficient (r) >= 0.996 for each analyte. For both human and mouse plasma, the accuracy and precision were within +/- 15% and <= 15%, respectively, for all concentrations, except for the lower limit of quantification, where they were within +/- 20% and <= 20%, respectively. A fit-for-purpose strategy was followed for tissue homogenates, and the accuracy and precision were within +/- 20% and <= 20%, respectively, for all concentrations. Stability of all analytes in all matrices at different processing and storage conditions was tested; ribociclib and palbociclib were unstable in most tissue homogenates and conditions were modified to increase the stability. The method was successfully applied for the analysis of mouse samples from preclinical studies. A new ribociclib metabolite was detected in mouse plasma samples with the same m/z transition as the parent drug.
引用
收藏
页码:5331 / 5345
页数:15
相关论文
共 50 条
  • [1] Development and validation of a bioanalytical method for the quantification of the CDK4/6 inhibitors abemaciclib, palbociclib, and ribociclib in human and mouse matrices using liquid chromatography-tandem mass spectrometry
    Alejandra Martínez-Chávez
    Hilde Rosing
    Michel Hillebrand
    Matthijs Tibben
    Alfred H. Schinkel
    Jos H. Beijnen
    Analytical and Bioanalytical Chemistry, 2019, 411 : 5331 - 5345
  • [2] Development and Validation of a Quantitative LC-MS/MS Method for CDK4/6 Inhibitors Palbociclib, Ribociclib, Abemaciclib, and Abemaciclib-M2 in Human Plasma
    Burke, Sarah M. M.
    Kamal, Mustafa K. L.
    Goey, Andrew K. L.
    THERAPEUTIC DRUG MONITORING, 2023, 45 (03) : 327 - 336
  • [3] Bioanalytical method development, validation and quantification of flupirtine maleate in rat plasma by liquid chromatography-tandem mass spectrometry
    Kandasamy, Karthikeyan
    Gowdra, Vasantharaju Surenahalli
    Nammalvar, Hariprabhu
    Govindarajan, Arul Kumaran Kottur S.
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2011, 61 (12): : 693 - 699
  • [4] Development and validation of bioanalytical method for quantification of cycloserine in human plasma by liquid chromatography-tandem mass spectrometry: Application to pharmacokinetic study
    Dodda, Sireesha
    Makula, Ajitha
    Kandhagatla, Raj Narayana
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (08)
  • [5] Bioanalytical method development and validation of a liquid chromatography-tandem mass spectrometry method for determination of β-lapachone in human plasma
    Putnam, William C.
    Kallem, Raja Reddy
    Subramaniyan, Indhumathy
    Beg, M. Shaalan
    Edpuganti, Vindhya
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 188
  • [6] Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of opiorphin in human saliva
    Brkljacic, Lidija
    Sabalic, Maja
    Salaric, Ivan
    Jeric, Ivanka
    Alajbeg, Ivan
    Nemet, Ina
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (32): : 3920 - 3926
  • [7] Quantification and Validation of Ertapenem Using a Liquid Chromatography-Tandem Mass Spectrometry Method
    van Rijn, S. P.
    Wessels, A. M. A.
    Greijdanus, B.
    Touw, D. J.
    Alffenaar, J. W. C.
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2014, 58 (06) : 3481 - 3484
  • [8] A Liquid Chromatography-Tandem Mass Spectrometry Bioanalytical Method Development and Validation for the Determination of Pacritinib in Plasma
    Kumar, Mulamraju Aruna
    Bangaraiah, Pagala
    SEPARATION SCIENCE PLUS, 2024, 7 (12):
  • [9] Bioanalytical Method Development and Validation of Selinexor in Rat Plasma by Liquid Chromatography-Tandem Mass Spectrometry
    Yaswanth, Murthaeti
    Sreekanth, M.
    Valli, Syed Sadaq
    Narayana, D. Venkata
    Sreedhar, V
    Venkataramana, Kanuma
    Pravallika, K. E.
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2022, 12 (04): : 41 - 53
  • [10] Method development and validation for rapid quantification of hydroxychloroquine in human blood using liquid chromatography-tandem mass Spectrometry
    Wang, Ling-Zhi
    Ong, Rina Yue-Ling
    Chin, Tan-Min
    Thuya, Win-Lwin
    Wan, Seow-Ching
    Wong, Andrea Li-Ann
    Chan, Sui-Yung
    Ho, Paul C.
    Goh, Boon-Cher
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 61 : 86 - 92