Automatic Extrinsic Self-Calibration for Fusing Data from Monocular Vision and 3-D Laser Scanner

被引:33
|
作者
Zhuang, Yan [1 ]
Yan, Fei [1 ]
Hu, Huosheng [2 ]
机构
[1] Dalian Univ Technol, Res Ctr Informat & Control, Dalian 116024, Peoples R China
[2] Univ Essex, Sch Comp Sci & Elect Engn, Colchester CO4 3SQ, Essex, England
基金
中国国家自然科学基金;
关键词
3-D laser scanner; data fusion; extrinsic calibration; monocular vision; RGB-D scene reconstruction;
D O I
10.1109/TIM.2014.2307731
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, an extrinsic self-calibration approach is proposed for solving the problem of real-time data fusion between monocular vision and 3-D laser scanner. A novel calibration board is designed for data fusion so that the extrinsic parameters can be obtained automatically by matching the corner features extracted from both vision and laser data. Experimental results obtained from both indoor and outdoor RGB-D scene reconstruction demonstrate the validity and good performance of the proposed approach.
引用
收藏
页码:1874 / 1876
页数:3
相关论文
共 50 条
  • [1] Self-calibration Method of Laser Scanning Projection System Combined with Monocular Vision
    Hou Maosheng
    Chen Yuqing
    Shi Zhengxue
    Li Zhuyue
    ACTA PHOTONICA SINICA, 2021, 50 (02)
  • [2] A method for the calibration of a 3-D laser scanner
    Niola, Vincenzo
    Rossi, Cesare
    Savino, Sergio
    Strano, Salvatore
    ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2011, 27 (02) : 479 - 484
  • [3] Self-calibration for a 3D laser
    Sheehan, Mark
    Harrison, Alastair
    Newman, Paul
    INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2012, 31 (05): : 675 - 687
  • [4] Automatic Extrinsic Self-Calibration of Mobile Mapping Systems Based on Geometric 3D Features
    Hillemann, Markus
    Weinmann, Martin
    Mueller, Markus S.
    Jutzi, Boris
    REMOTE SENSING, 2019, 11 (16)
  • [5] Complete 3-D self-calibration of coordinate measuring machines
    Dang, Q. C.
    Yoo, S.
    Kim, S. -W.
    CIRP ANNALS-MANUFACTURING TECHNOLOGY, 2006, 55 (01) : 527 - 530
  • [6] Accurate and Automatic Extrinsic Calibration for a Monocular Camera and Heterogenous 3D LiDARs
    Li, Xingxing
    He, Feiyang
    Li, Shengyu
    Zhou, Yuxuan
    Xia, Chunxi
    Wang, Xuanbin
    IEEE SENSORS JOURNAL, 2022, 22 (16) : 16472 - 16480
  • [7] Extraction of features from 3-D laser scanner cloud data
    Chan, V
    Bradley, C
    Vickers, G
    THREE-DIMENSIONAL IMAGING AND LASER-BASED SYSTEMS FOR METROLOGY AND INSPECTION III, 1997, 3204 : 185 - 191
  • [8] Improving plane extraction from 3D data by fusing laser data and vision
    Andreasson, H
    Triebel, R
    Burgard, W
    2005 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-4, 2005, : 1289 - 1294
  • [9] A Self-Calibration Method for Engineering Using 3-D Laser Scanning System Based on Cube Vertices
    Chen, Hongqiang
    Xia, Ruiheng
    Zhang, Yi
    Deng, Hua
    Li, Kejun
    IEEE SENSORS JOURNAL, 2024, 24 (03) : 3247 - 3258
  • [10] Self-calibration method for pulse-3D terrestrial laser scanner based on least-square collocation
    Guo X.-T.