Optical sensor for carbon dioxide gas determination, characterization and improvements

被引:12
|
作者
Aguayo-Lopez, M. L. [1 ]
Capitan-Vallvey, L. F. [1 ]
Fernandez-Ramos, M. D. [1 ]
机构
[1] Univ Granada, ECsens, Fac Sci, Dept Analyt Chem, E-18071 Granada, Spain
关键词
Carbon dioxide; Gas sensor; Phosphorescence; Hydrophilic polymer; PH-INDICATOR; FILMS; CO2; OXYGEN; BASE;
D O I
10.1016/j.talanta.2014.03.050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A study of different alternatives to improve the stability and lifetime of sensors for the determination of gaseous CO2 has been performed. It includes the characterization of different sensing membranes, a discussion of the results obtained and possibilities for the future. The solid sensor membrane for gaseous CO2 based on changes in the luminiscence of a luminophore immobilized on O-2-insensitive film, concurrent with the displacement of a pH indicator, has some drawbacks, such as the loss of efficiency over time and the need to maintain the sensor in special atmospheric conditions. As a solution to these drawbacks, two alternatives were tested, the first alternative was replacing the newly proposed tetraoctyl ammonium hydroxide (TOAOH) phase transfer agent with other basic agents that did not undergo a Hoffman degradation reaction, and the second alternative was the use of hydrophilic polymers that could retain water needed for CO2 sensing more efficiently. The different membranes tested indicated that the use of tetramethyl ammonium (TMAOH) instead of TOAOH as the phase transfer agent produced better results regarding stability and sensitivity. In addition, replacing the membrane polymer with hydrophilic polymers improved the sensing characteristics in terms of response time and stability over hydrophobic polymers. With a detection limit of 0.006%, the response time is 19 s and the recovery time is 100 s. The lifetime of the sensing membranes, which do not need to be held in any special atmosphere other than darkness, is longer than at least 300 days for membranes with TMAOH in hydrophilic polymer and 515 days for membranes with TMAOH in ethyl cellulose. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:196 / 201
页数:6
相关论文
共 50 条
  • [1] Solid state electrochemical gas sensor for the quantitative determination of carbon dioxide
    Schwandt, Carsten
    Kumar, R. Vasant
    Hills, Matthew P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 265 : 27 - 34
  • [2] Research on Long Optical Path and Resonant Carbon Dioxide Gas Photoacoustic Sensor
    Li Zhen-gang
    Si Gan-shang
    Ning Zhi-qiang
    Liu Jia-xiang
    Fang Yong-hua
    Cheng Zhen
    Si Bei-bei
    Yang Chang-ping
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43 (01) : 43 - 49
  • [3] Carbon dioxide gas sensor based on optical control of color in liquid indicator
    Oblov, K. Yu
    Ivanova, A. V.
    Soloviev, S. A.
    Zhdanov, S. V.
    Voronov, Yu A.
    Florentsev, V. V.
    1ST INTERNATIONAL TELECOMMUNICATION CONFERENCE ADVANCED MICRO- AND NANOELECTRONIC SYSTEMS AND TECHNOLOGIES, 2016, 151
  • [4] Phase fluorometric optical carbon dioxide gas sensor for fermentation off-gas monitoring
    Sipior, J
    RandersEichhorn, L
    Lakowicz, JR
    Carter, GM
    Rao, G
    BIOTECHNOLOGY PROGRESS, 1996, 12 (02) : 266 - 271
  • [5] Phase fluorometric optical carbon dioxide gas sensor for fermentation off-gas monitoring
    Univ of Maryland at Baltimore, Baltimore, United States
    Biotechnol Prog, 2 (266-271):
  • [6] DETERMINATION OF CARBON DIOXIDE IN GAS STREAMS
    TOREN, PE
    HEINRICH, BJ
    ANALYTICAL CHEMISTRY, 1957, 29 (12) : 1854 - 1856
  • [7] Optical sensor for sulfur dioxide determination in wines
    Silva, Karime R. B.
    Raimundo, Ivo M., Jr.
    Gimenez, Iara F.
    Alves, Oswaldo L.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2006, 54 (23) : 8697 - 8701
  • [8] CONDUCTIMETRIC GAS SENSOR FOR CARBON-DIOXIDE
    HIMPLER, HA
    BRAND, SF
    BRAND, MJD
    ANALYTICAL CHEMISTRY, 1978, 50 (12) : 1623 - 1627
  • [9] POTENTIOMETRIC GAS SENSOR FOR CARBON-DIOXIDE
    MOKHALLALATI, AO
    ISTUDOR, A
    VIRTOSU, D
    LUCA, C
    REVUE ROUMAINE DE CHIMIE, 1985, 30 (01) : 31 - 36
  • [10] NIR optical carbon dioxide gas sensor based on simple azaBODIPY pH indicators
    Fernandez-Ramos, M. D.
    Aguayo-Lopez, M. L.
    de los Reyes-Berbel, E.
    Santoyo-Gonzalez, F.
    Capitan-Vallvey, L. F.
    ANALYST, 2019, 144 (12) : 3870 - 3877