The Relative Exposure of the Operating Room Staff to Sevoflurane During Intracerebral Surgery

被引:21
|
作者
Tanko, Bela [1 ]
Molnar, Csilla [1 ]
Budi, Timea [1 ]
Peto, Csaba [1 ]
Novak, Laszlo [1 ]
Fuelesdi, Bela [1 ]
机构
[1] Univ Debrecen, Hlth & Med Sci Ctr, Dept Anesthesiol & Intens Care, H-4012 Debrecen, Hungary
来源
ANESTHESIA AND ANALGESIA | 2009年 / 109卷 / 04期
关键词
NITROUS-OXIDE; SUBANESTHETIC CONCENTRATIONS; OCCUPATIONAL-EXPOSURE; HEALTHY-VOLUNTEERS; HALOTHANE; RATS; PERFORMANCE; ISOFLURANE; ANESTHESIA; ENFLURANE;
D O I
10.1213/ane.0b013e3181b0cbea
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Our primary aim in this study was to investigate whether escape of the volatile anesthetic sevoflurane from the surgical site during craniotomy for tumor resection increases the exposure of the neurosurgeon to the anesthetic when compared with the anesthesiologist. METHODS: Initially, the release of sevoflurane from the surgical site was measured during 35 tumorectomies starting from opening to closure of the dura. Volatile anesthetic absorbers were placed at three detection sites: 1) the surgeon's breathing zone, 2) the anesthesiologist's breathing zone, and 3) the farthest corner of the operation room. In the second sampling series that included 16 patients, the detector that had been in the corner of the operating room in the first series was now placed in the vicinity of the patient's mouth (within 5 cm). Sevoflurane captured by the absorbers was quantified by an independent chemist using chromatography. RESULTS: Absorbers in the surgeon's breathing zone (0.24 +/- 0.04 ppm) captured a significantly lower amount of sevoflurane compared with absorbers in the anesthesiologist's breathing zone (1.40 +/- 0.37 ppm) and comparable with that in the farthest corner of the operation room (0.25 +/- 0.07 ppm). There was no correlation between the amount of absorbed sevoflurane and the size of craniotomy window, even when adjusting for the variation in duration of surgery. In the second series of sampling, absorbers in the proximity of the patient's mouth captured the highest amount of sevoflurane (1.54 +/- 0.55 ppm), followed by the anesthesiologist's (1.14 +/- 0.43 ppm) and the surgeon's (0.15 +/- 0.05 ppm) breathing zones. CONCLUSIONS: The close proximity of the surgeon's breathing zone to the craniotomy window does not appear to be a source of increased exposure to sevoflurane. The observed higher exposure of the anesthesiologist to sevoflurane in the operating room environment warrants further exploration. (Anesth Analg 2009;109:1187-92)
引用
收藏
页码:1187 / 1192
页数:6
相关论文
共 50 条
  • [1] Occupational exposure to sevoflurane and nitrous oxide in operating room personnel
    Hoerauf, KH
    Koller, C
    Taeger, K
    Hobbhahn, J
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1997, 69 (02) : 134 - 138
  • [2] EXPOSURE CHARACTERISTICS AND CUTANEOUS PROBLEMS IN OPERATING-ROOM STAFF
    HOLNESS, DL
    TARLO, SM
    SUSSMAN, G
    NETHERCOTT, JR
    CONTACT DERMATITIS, 1995, 32 (06) : 352 - 358
  • [3] Probabilistic health risk assessment of occupational exposure to isoflurane and sevoflurane in the operating room
    Dehghani, Fatemeh
    Kamalinia, Mojtaba
    Omidi, Fariborz
    Fallahzadeh, Reza Ali
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2021, 207
  • [4] OCCUPATIONAL EXPOSURE TO SEVOFLURANE AND NITROUS-OXIDE IN OPERATING-ROOM PERSONNEL
    HOERAUF, K
    KOLLER
    WIESNER, G
    TAEGER, K
    HOBBHAHN, J
    ANESTHESIOLOGY, 1994, 81 (3A) : A553 - A553
  • [5] Sevoflurane inside and outside the operating room
    Michel, Fabrice
    Constantin, Jean-Michel
    EXPERT OPINION ON PHARMACOTHERAPY, 2009, 10 (05) : 861 - 873
  • [6] STUDY OF EFFECTS OF EXPOSURE TO HALOTHANE UPON AN OPERATING-ROOM STAFF
    BRACHETLIERMAIN, A
    VARENE, N
    LEPINE, G
    GILLARDEAU, G
    THERAPIE, 1977, 32 (05): : 585 - 601
  • [7] Radiation exposure to operating room staff during prostate brachytherapy using iodine-125 seeds
    Gagna, G.
    Gauron, C.
    Amabile, J-C
    Laroche, P.
    RADIOPROTECTION, 2011, 46 (02) : 189 - 208
  • [8] Sevoflurane use does not decrease operating room stays in pediatric outpatient surgery
    Watcha, MF
    ANESTHESIOLOGY, 1996, 85 (3A) : A1091 - A1091
  • [9] Radiation Exposure of Patient and Operating Room Personnel by Fluoroscopy and Navigation during Spinal Surgery
    G. Bratschitsch
    L. Leitner
    G. Stücklschweiger
    H. Guss
    P. Sadoghi
    P. Puchwein
    A. Leithner
    R. Radl
    Scientific Reports, 9
  • [10] Radiation Exposure of Patient and Operating Room Personnel by Fluoroscopy and Navigation during Spinal Surgery
    Bratschitsch, G.
    Leitner, L.
    Stuecklschweiger, G.
    Guss, H.
    Sadoghi, P.
    Puchwein, P.
    Leithner, A.
    Radl, R.
    SCIENTIFIC REPORTS, 2019, 9 (1)