Optimal metallic salt-ammonia reaction couple for single effect solid-gas chemical heat pump

被引:1
|
作者
Han, JH [1 ]
Cho, KW [1 ]
Lee, KH [1 ]
Lee, HK [1 ]
机构
[1] Pohang Univ Sci & Technol, Dept Chem Engn, Nam Ku, Pohang 790784, Kyungbuk, South Korea
关键词
refrigeration; metallic salt-ammonia; chemical heat pump;
D O I
10.1007/BF02707152
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A comparison of the coefficient of performance (COP), the specific cooling power (SCP) and the reactor volume per output power was carried out with numerous metallic salt-ammonia couples for single effect solid-gas chemical heat pumps. Optimal reaction couples could be selected in terms of COP, SCP and reactor volume at: each application domain of deep freezing (-15 similar to-20 degrees C), ice making (-10 similar to-5 degrees C) and air conditioning (0-10 degrees C).
引用
收藏
页码:248 / 251
页数:4
相关论文
共 10 条
  • [1] Optimal metallic salt-ammonia reaction couple for single effect solid-gas chemical heat pump
    Jong Hun Han
    Kil-Won Cho
    Kun-Hong Lee
    Ho-Kyung Lee
    Korean Journal of Chemical Engineering, 2000, 17 : 248 - 251
  • [2] Experimental Performance of Solid-Gas Chemical Heat Pump in Solar Chemical Heat Pump Dryer
    Ibrahim, M.
    Sopian, K.
    Hussein, A. S.
    Daud, W. R. W.
    Zaharim, A.
    RECENT ADVANCES IN ENERGY AND ENVIRONMENT: PROCEEDINGS OF THE 4TH IASME/WSEAS INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT (EE'09), 2009, : 405 - +
  • [3] Performance of Solid-Gas Chemical Heat Pump Subsystem of Solar Dryer
    Ibrahim, M.
    Daud, W. R. W.
    Ibrahim, Kamaruzaman
    Zaharim, Azami
    Sopian, Kamaruzaman
    PROCEEDINGS OF THE AMERICAN CONFERENCE ON APPLIED MATHEMATICS: RECENT ADVANCES IN APPLIED MATHEMATICS, 2009, : 499 - +
  • [4] SOLID-GAS CHEMICAL HEAT-PUMPS - FIELD OF APPLICATION AND PERFORMANCE OF THE INTERNAL HEAT OF REACTION RECOVERY PROCESS
    NEVEU, P
    CASTAING, J
    HEAT RECOVERY SYSTEMS & CHP, 1993, 13 (03): : 233 - 251
  • [5] SINGLE NONISOTHERMAL NONCATALYTIC SOLID-GAS REACTION - EFFECT OF CHANGING PARTICLE-SIZE
    REHMAT, A
    SAXENA, SC
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1976, 15 (02): : 343 - 350
  • [6] Experimental studies on a novel chemical heat pump dryer using a gas-solid reaction
    Ogura, H
    Ishida, H
    Yokooji, R
    Kage, H
    Matsuno, Y
    Mujumdar, AS
    DRYING TECHNOLOGY, 2001, 19 (07) : 1461 - 1477
  • [7] THE STRUCTURE AND PERFORMANCE OF SINGLE EFFECT SOLID GAS CHEMICAL HEAT-PUMPS
    GOETZ, V
    ELIE, F
    SPINNER, B
    HEAT RECOVERY SYSTEMS & CHP, 1993, 13 (01): : 79 - 96
  • [8] CHEMICAL CONSEQUENCES OF A POLAR AXIS IN A SOLID-GAS REACTION - REACTION OF PARA-BROMOBENZOIC ANHYDRIDE CRYSTALS WITH AMMONIA GAS - THE ABSOLUTE DIRECTION OF A POLAR UNITROPIC REACTION AND THE RELATIONSHIP OF ABSOLUTE-CONFIGURATION WITH CRYSTAL MORPHOLOGY
    DUESLER, EN
    KRESS, RB
    LIN, CT
    SHIAU, WI
    PAUL, IC
    CURTIN, DY
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1981, 103 (04) : 875 - 879
  • [9] A MODEL FOR REVERSIBLE SOLID GAS REACTIONS SUBMITTED TO TEMPERATURE AND PRESSURE CONSTRAINTS - SIMULATION OF THE RATE OF REACTION IN SOLID GAS REACTOR USED AS CHEMICAL HEAT-PUMP
    GOETZ, V
    MARTY, A
    CHEMICAL ENGINEERING SCIENCE, 1992, 47 (17-18) : 4445 - 4454
  • [10] VOLUME CHANGE OF SOLID SUBSTANCES IN CACL2/CH3NH2 GAS-SOLID REACTION USED FOR DRIVING A CHEMICAL HEAT-PUMP
    HIRATA, Y
    FUJIOKA, K
    OKAZAKI, T
    FUJII, Y
    ITO, R
    DOI, A
    KAGAKU KOGAKU RONBUNSHU, 1993, 19 (02) : 338 - 344