A Novel Fourier Transform Ion Cyclotron Resonance Mass Spectrometer with Improved Ion Trapping and Detection Capabilities

被引:17
|
作者
Kaiser, Nathan K. [1 ]
Skulason, Gunnar E. [1 ]
Weisbrod, Chad R. [1 ]
Bruce, James E. [1 ]
机构
[1] Washington State Univ, Dept Chem, Pullman, WA 99164 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
MOLECULAR-WEIGHT DISTRIBUTIONS; TOP-DOWN; EXTERNAL ACCUMULATION; FUNNEL INTERFACE; GAIN-CONTROL; RESOLUTION; PERFORMANCE; PROTEIN; CELL; CLOUD;
D O I
10.1016/j.jasms.2008.12.022
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer has been developed for improved biomolecule analysis. A flared metal capillary and an electrodynamic ion funnel were installed in the Source region of the instrument for improved ion transmission. The transfer quadrupole is divided into 19 segments, with the capacity for independent control of DC voltage biases for each segment. Restrained ion population transfer (RIPT) is used to transfer ions from the ion accumulation region to the ICR cell. The RIPT ion guide reduces mass discrimination that occurs as a result of time-of-flight effects associated with gated trapping. Increasing the number of applied DC bias voltages from 8 to 18 increases the number of ions that are effectively trapped in the ICR cell. The RIPT ion guide with a novel voltage profile applied during ion transfer provides a 3- to 4-fold increase in the number of ions that are trapped in the ICR cell compared with gated trapping for the same ion accumulation time period. A novel ICR cell was incorporated in the instrument to reduce radial electric field variation for ions with different z-axis oscillation amplitudes. With the ICR cell, called trapping ring electrode cell (TREC), we can tailor the shape of the trapping electric fields to reduce dephasing of coherent cyclotron motion of all excited ion packet. With TREC, nearly all order of magnitude increase in sensitivity is observed. The performance of the instrument with the combination of RIPT, TREC, flared inlet, and ion funnel is presented. (J Am Soc Mass Spectrom 2009, 20, 755-762) (C) 2009 Published by Elsevier Inc. on behalf of American Society for Mass Spectrometry
引用
收藏
页码:755 / 762
页数:8
相关论文
共 50 条
  • [1] TRAPPING, DETECTION, AND MASS MEASUREMENT OF INDIVIDUAL IONS IN A FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETER
    BRUCE, JE
    CHENG, X
    BAKHTIAR, R
    WU, Q
    HOFSTADLER, SA
    ANDERSON, GA
    SMITH, RD
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (17) : 7839 - 7847
  • [2] Development of a Fourier-transform ion cyclotron resonance mass spectrometer-ion mobility spectrometer
    Bluhm, BK
    Gillig, KJ
    Russell, DH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (11): : 4078 - 4086
  • [4] Improved ion optics for introduction of ions into a 9.4-T Fourier transform ion cyclotron resonance mass spectrometer
    Chen, Yu
    Leach, Franklin E., III
    Kaiser, Nathan K.
    Dang, Xibei
    Ibrahim, Yehia M.
    Norheim, Randolph V.
    Anderson, Gordon A.
    Smith, Richard D.
    Marshall, Alan G.
    JOURNAL OF MASS SPECTROMETRY, 2015, 50 (01): : 280 - 284
  • [5] Central ring electrode for trapping and excitation/detection in Fourier transform ion cyclotron resonance mass spectrometry
    Ostrander, CM
    Arkin, CR
    Laude, D
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (01) : 30 - 37
  • [6] Sharing a pair of electrodes between excitation and detection in a Fourier transform ion cyclotron resonance mass spectrometer
    Laboratoire de Physico-Chimie des Rayonnements, Université de Paris-Sud, 91405 Orsay, France
    Rapid Commun. Mass Spectrom., 5 (591-593):
  • [7] Sharing a pair of electrodes between excitation and detection in a Fourier transform ion cyclotron resonance mass spectrometer
    Mauclaire, G
    Lemaire, J
    Heninger, M
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (05) : 591 - 593
  • [8] Rapid microscale analyses with an external ion source Fourier transform ion cyclotron resonance mass spectrometer
    Heeren, RMA
    Boon, JJ
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1996, 157 : 391 - 403
  • [9] Dynamic ion trapping in a cylindrical open cell for Fourier transform ion cyclotron resonance mass spectrometry
    Frankevich, V
    Zenobi, R
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 207 (1-2) : 57 - 67
  • [10] Design and performance of an atmospheric pressure ion mobility Fourier transform ion cyclotron resonance mass spectrometer
    Tang, Xiaoting
    Bruce, James E.
    Hill, Herbert H., Jr.