Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

被引:42
|
作者
Richter, Daniel [1 ,2 ]
Saito, Nami [1 ]
Chaudhri, Naved [3 ]
Haertig, Martin [4 ]
Ellerbrock, Malte [3 ]
Jaekel, Oliver [3 ,4 ]
Combs, Stephanie E. [4 ]
Habermehl, Daniel [4 ]
Herfarth, Klaus [4 ]
Durante, Marco [1 ,2 ]
Bert, Christoph [1 ,5 ,6 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch, Dept Biophys, Darmstadt, Germany
[2] Tech Univ Darmstadt, Darmstadt, Germany
[3] Heidelberg Ion Beam Therapy Ctr, Dept Med Phys, Heidelberg, Germany
[4] Univ Heidelberg Hosp, Dept Radiat Oncol, Heidelberg, Germany
[5] Univ Clin Erlangen, Erlangen, Germany
[6] Univ Erlangen Nurnberg, Dept Radiat Oncol, D-91054 Erlangen, Germany
关键词
DEFORMABLE IMAGE REGISTRATION; RADIATION-THERAPY; RESPIRATORY MOTION; GATED IRRADIATION; PARTICLE BEAMS; RADIOTHERAPY; TARGETS; VERIFICATION; VALIDATION; ALGORITHM;
D O I
10.1016/j.ijrobp.2014.01.043
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)-weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporal correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V-95) and 107% (V-107) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V-95 and V-107 values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V-95 > 87%, SD < 3%) and overdose (mean V-107 < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment. (C) 2014 Elsevier Inc.
引用
收藏
页码:175 / 181
页数:7
相关论文
共 50 条
  • [1] Four-Dimensional Dose Reconstruction for Scanned Proton Therapy Using Liver 4DCT-MRI
    Bernatowicz, Kinga
    Peroni, Marta
    Perrin, Rosalind
    Weber, Damien C.
    Lomax, Antony
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (01): : 216 - 223
  • [2] Assessment of Uncertainties in Treatment Planning for Scanned Ion Beam Therapy of Moving Tumors
    Hild, Sebastian
    Durante, Marco
    Bert, Christoph
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (02): : 528 - 535
  • [3] Robustness of target dose coverage to motion uncertainties for scanned carbon ion beam tracking therapy of moving tumors
    Eley, John Gordon
    Newhauser, Wayne David
    Richter, Daniel
    Luechtenborg, Robert
    Saito, Nami
    Bert, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (04): : 1717 - 1740
  • [4] 4D Treatment Dose Reconstruction for Scanned Ion Beam Therapy
    Richter, D.
    Saito, N.
    Chaudhri, N.
    Haertig, M.
    Combs, S.
    Habermehl, D.
    Herfarth, K.
    Jaekel, O.
    Durante, M.
    Bert, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S183 - S183
  • [5] 4D Optimization for Scanned Ion Beam Tracking Therapy for Moving Tumors
    Eley, J.
    Graeff, C.
    Luechtenborg, R.
    Durante, M.
    Howell, R.
    Newhauser, W.
    Bert, C.
    MEDICAL PHYSICS, 2012, 39 (06) : 3970 - 3970
  • [6] 4D optimization of scanned ion beam tracking therapy for moving tumors
    Eley, John Gordon
    Newhauser, Wayne David
    Luechtenborg, Robert
    Graeff, Christian
    Bert, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (13): : 3431 - 3452
  • [7] Four-Dimensional Dose Reconstruction for Lung Cancer in Volumetric Modulated Arc Therapy
    Hashimoto, M.
    Ito, Y.
    Takahashi, R.
    Nakajima, M.
    Matsubayashi, F.
    Saotome, S.
    Kitamura, N.
    Sato, T.
    Kozuka, T.
    Oguchi, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E611 - E611
  • [8] Measurement of the four-dimensional transverse emittance of an ion beam
    Zeinoun, I
    Benveniste, V
    Saadatmand, K
    Swenson, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 1194 - 1196
  • [9] Fast optimization and dose calculation in scanned ion beam therapy
    Hild, S.
    Graeff, C.
    Trautmann, J.
    Kraemer, M.
    Zink, K.
    Durante, M.
    Bert, C.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [10] A Novel Dose Reconstruction Method for Four-Dimensional Treatment Planning
    Zhong, H.
    Kim, J.
    Glide-Hurst, C.
    Chetty, I.
    MEDICAL PHYSICS, 2010, 37 (06)