Experimental evaluation of FRP jackets in upgrading RC corroded columns with substandard detailing

被引:72
|
作者
Tastani, SP [1 ]
Pantazopoulou, SJ [1 ]
机构
[1] Democritus Univ Thrace, Dept Civil Engn, GR-67100 Xanthi, Greece
关键词
corrosion; FRP jacketing; concrete confinement; repair/strengthening; rehabilitation; non-conforming (substandard) details;
D O I
10.1016/j.engstruct.2004.02.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Reinforced concrete columns designed and built prior to the introduction of modern detailing practices are often susceptible to the compounded influences of reinforcement corrosion owing to carbonation or exposure to the marine environment, a circurnstance that decimates even further the limited safety reserves of old-type construction. This problem was witnessed repeatedly during the recent earthquakes in Southern Europe. fit this paper, the structural behavior of corrosion-damaged columns with reinforcement details representative of pre-1980s Codes of practice was studied through an experimental program comprising 21 prismatic specimens. Columns were upgraded by means of FRP jacketing after being conditioned to accelerated electrochemical corrosion, and were subsequently tested to failure under concentric compression; some specimens were subjected to a repeated cycle of corrosion conditioning after jacketing and prior to mechanical testing. Primary variables of the investigation were the jacket characteristics and the repair method applied. Parameters used to gauge the performance of the upgrade were, the efficacy of the jacket in recovering the strength and in enhancing the deformation capacity of the columns, as well as in slowing down the depletion of reinforcement during the post-repair corrosion cycle. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:817 / 829
页数:13
相关论文
共 50 条
  • [1] Experimental investigation of substandard RC columns confined with SRG jackets under compression
    Thermou, Georgia E.
    Katakalos, Konstantinos
    Manos, George
    COMPOSITE STRUCTURES, 2018, 184 : 56 - 65
  • [2] Seismic retrofitting of RC columns with FRP jackets
    Seible, F
    COMPOSITE AND HYBRID STRUCTURES, VOLS 1 AND 2, 2000, : 903 - 910
  • [3] Lateral prestressing of RC columns with FRP jackets
    Mortazavi, AA
    Pilakoutas, K
    Ciupala, MA
    FIBRE-REINFORCEMENT POLYMER: REINFORCEMENT FOR CONCRETE STRUCTURES, VOLS 1 AND 2, PROCEEDINGS, 2003, : 643 - 652
  • [4] Experimental evaluation of seismic performance of corroded precast RC bridge columns and the retrofit measure using CFRP jackets
    Wang, Xu
    Wu, Suiwen
    Jia, Junfeng
    Li, Huaqiang
    Wei, Yanjian
    Zhang, Kaidi
    Bai, Yulei
    ENGINEERING STRUCTURES, 2021, 245
  • [5] Numerical Modeling of the Flexural Behaviour of Substandard Columns Reinforced with RC Jackets
    Minafò, G.
    Camarda, G.
    Papia, M.
    La Mendola, L.
    Lecture Notes in Civil Engineering, 2023, 351 : 697 - 708
  • [6] An experimental and corrosion study on the effect of environmental exposures on RC columns with FRP composite jackets
    Belarbi, Abdeldjelil
    Bae, Sang-Wook
    COMPOSITES PART B-ENGINEERING, 2007, 38 (5-6) : 674 - 684
  • [7] Design of FRP Jackets for Plastic Hinge Confinement of RC Columns
    Pantelides, Chris P.
    Moran, Domingo A.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2013, 17 (04) : 433 - 442
  • [8] Development of Fragility Curves for RC Columns Retrofitted with FRP Jackets
    García, Oscar Minor
    Murcia-Delso, Juan
    Oller, Eva
    Lecture Notes in Civil Engineering, 2023, 350 LNCE : 488 - 498
  • [9] Experimental study on the mechanical properties of corroded RC columns repaired with large rupture strain FRP
    Li, Pengda
    Ren, Yuhao
    Zhou, Yingwu
    Zhu, Zengzhu
    Chen, Yueding
    JOURNAL OF BUILDING ENGINEERING, 2022, 54
  • [10] An experimental investigation on ultimate strength of RC columns strengthened by RC jackets
    Gao, Fei
    Zhang, Jun-Bing
    Li, Wei-Ming
    STRUCTURAL CONDITION ASSESSMENT, MONITORING AND IMPROVEMENT, VOLS 1 AND 2, 2007, : 1127 - 1132