High-throughput Quant-iT PicoGreen assay using an automated liquid handling system

被引:11
|
作者
Anantanawat, Kay [1 ,2 ]
Pitsch, Nicola [1 ]
Fromont, Caroline [1 ,3 ]
Janitz, Caroline [1 ]
机构
[1] Western Sydney Univ, Next Generat Sequencing Facil, Sydney, NSW, Australia
[2] Univ Technol Sydney, Ithree Inst, Sydney, NSW, Australia
[3] Cornell Univ, Dept Entomol, Ithaca, NY 14853 USA
关键词
DNA library; high-throughput; liquid handling systems; next-generation sequencing; PicoGreen assay;
D O I
10.2144/btn-2018-0172
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Workflows in NGS facilities require high-standard practices and high-throughput pipelines to process the large number of samples received in a timely manner. Downstream protocols such as NGS library preparation require accurate estimation of nucleic acid concentrations, which can be achieved using fluorescent dye-based nucleic acid measurement. Here, we report a protocol for preparing a 384-well Quant-iT PicoGreen assay. The protocol allows the concentrations of 184 DNA samples to be measured simultaneously in duplicate in only 1 h using an Eppendorf epMotion 5075 liquid handling system. The advantages of this high-throughput approach include a reduction in both reagents (10x less reagents compared to a standard protocol) and time (3 h for 384 samples compared with 3 days). METHOD SUMMARY We describe a protocol for preparing a 384-well Quant-iT PicoGreen assay for utilization in a NGS pipeline. The protocol allows the concentrations of 184 DNA samples to be measured simultaneously in duplicate in only 1 h using an Eppendorf epMotion 5075 liquid handling system.
引用
收藏
页码:290 / 294
页数:5
相关论文
共 50 条
  • [1] High-throughput screening of molecular catalysts using automated liquid handling, injection, and microdevices
    de Bellefon, C
    Abdallah, R
    Lamouille, T
    Pestre, N
    Caravieilhes, S
    Grenouillet, P
    CHIMIA, 2002, 56 (11) : 621 - 626
  • [2] A fluorescent high-throughput assay for double-stranded DNA: the RediPlate PicoGreen assay
    Batchelor, R
    Hagen, D
    Johnson, I
    Beechem, J
    COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2003, 6 (04) : 287 - 291
  • [3] Precise Automation for High-Throughput Liquid Handling
    Scoffin, Katriona
    AMERICAN LABORATORY, 2014, 46 (01) : 17 - 19
  • [4] Inhibitors of Streptococcus pneumoniae Surface Endonuclease EndA Discovered by High-Throughput Screening Using a PicoGreen Fluorescence Assay
    Peterson, Eliza J. R.
    Kireev, Dmitri
    Moon, Andrea F.
    Midon, Marika
    Janzen, William P.
    Pingoud, Alfred
    Pedersen, Lars C.
    Singleton, Scott F.
    JOURNAL OF BIOMOLECULAR SCREENING, 2013, 18 (03) : 247 - 257
  • [5] High-throughput transformation of Saccharomyces cerevisiae using liquid handling robots
    Liu, Guangbo
    Lanham, Clayton
    Buchan, J. Ross
    Kaplan, Matthew E.
    PLOS ONE, 2017, 12 (03):
  • [6] EXPANSION OF IN VITRO DRUG METABOLISM ASSAY CAPACITY AND EFFICIENCY WITH HIGH THROUGHPUT SCREENING USING AUTOMATED LIQUID HANDLING
    Schofield, Andrew
    Zhu, Bruce
    Welsh, Christopher
    Pham, Chuong
    DRUG METABOLISM AND PHARMACOKINETICS, 2020, 35 (01) : S65 - S65
  • [7] Enabling High-throughput Transgene Expression Studies Using Automated Liquid Handling for Etiolated Maize Leaf Protoplasts
    Rigoulot, Stephen B.
    Park, Jeongmoo
    Fabish, Jonathan
    Seaberry, Erin M.
    Parrish, Allison
    Meier, Kerry A.
    Whinna, Rachel
    Dong, Shujie
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (204):
  • [8] Liquid Handling Optimization in High-Throughput Biodosimetry Tool
    Bian, Dakai
    Tsui, Jason C.
    Repin, Mikhail
    Garty, Guy
    Turner, Helen
    Yao, Y. Lawrence
    Brenner, David J.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (04):
  • [9] Automated high-throughput sex-typing assay
    Yu, LZ
    Martínez, FD
    Klimecki, WT
    BIOTECHNIQUES, 2004, 37 (04) : 662 - 664
  • [10] Automated High-throughput Fucosyltransferase Inhibition Assay on a Chip
    Leclerc, Laura
    Kwan, David
    Shih, Steve
    PROTEIN SCIENCE, 2017, 26 : 89 - 89